@ -23,7 +23,9 @@
|
||||
* Generic Modbus energy meter
|
||||
*
|
||||
* - Supports single three phase device or three single phase devices of same model on bus.
|
||||
* - Uses a rule file called modbus allowing for easy configuration of modbus energy monitor device(s).
|
||||
* - For easy configuration of modbus energy monitor device(s) use:
|
||||
* - a rule file called modbus
|
||||
* - a filesystem file called modbus.json
|
||||
*
|
||||
* Value pair description:
|
||||
* {"Name":"SDM230","Baud":2400,"Config":8N1","Address":1,"Function":4,"Voltage":0,"Current":6,"Power":12,"ApparentPower":18,"ReactivePower":24,"Factor":30,"Frequency":70,"Total":342,"ExportActive":0x004A}
|
||||
@ -124,6 +126,7 @@
|
||||
* rule3 on file#modbus do {"Name":"PZEM014","Baud":9600,"Config":"8N1","Address":1,"Function":4,"Voltage":{"R":0,"T":3,"F":-1},"Current":{"R":1,"T":8,"F":-3},"Power":{"R":3,"T":8,"F":-1},"Factor":{"R":8,"T":3,"F":-2},"Frequency":{"R":7,"T":3,"F":-1},"Total":{"R":5,"T":8,"F":-3}} endon
|
||||
* rule3 on file#modbus do {"Name":"3 x PZEM014","Baud":9600,"Config":"8N1","Address":[1,2,3],"Function":4,"Voltage":{"R":0,"T":3,"F":-1},"Current":{"R":1,"T":8,"F":-3},"Power":{"R":3,"T":8,"F":-1},"Factor":{"R":8,"T":3,"F":-2},"Frequency":{"R":7,"T":3,"F":-1},"Total":{"R":5,"T":8,"F":-3}} endon
|
||||
* rule3 on file#modbus do {"Name":"Solax X3MIC","Baud":9600,"Config":"8N1","Address":1,"Function":4,"Voltage":{"R":0x0404,"T":3,"F":-1},"Power":{"R":0x040e,"T":3,"F":0},"Total":{"R":0x0423,"T":8,"F":-3}} endon
|
||||
* rule3 on file#modbus do {"Name":"WE517","Baud":9600,"Config":"8E1","Address":1,"Function":3,"Voltage":[0xE,0x10,0x12],"Current":[0x16,0x18,0x1A],"Power":[0x1E,0x20,0x22],"ReactivePower":[0x26,0x28,0x2A],"Factor":[0x36,0x38,0x3A],"Frequency":0x14,"Total":0x100} endon
|
||||
*
|
||||
* Example using default Energy registers and some user defined registers:
|
||||
* rule3 on file#modbus do {"Name":"SDM72","Baud":9600,"Config":"8N1","Address":0x01,"Function":0x04,"Power":0x0034,"Total":0x0156,"ExportActive":0x004A,"User":[{"R":0x0502,"J":"ImportActive","G":"Import Active","U":"kWh","D":24},{"R":0x0502,"J":"ExportPower","G":"Export Power","U":"W","D":23},{"R":0x0500,"J":"ImportPower","G":"Import Power","U":"W","D":23}]} endon
|
||||
@ -180,6 +183,9 @@
|
||||
//#define ENERGY_MODBUS_DEBUG
|
||||
//#define ENERGY_MODBUS_DEBUG_SHOW
|
||||
|
||||
#define ENERGY_MODBUS_FILE "/modbus.json" // Modbus parameter file name used by filesystem
|
||||
#define ENERGY_MODBUS_MAX_FSIZE 1024 // Modbus parameter file max size
|
||||
|
||||
const uint16_t nrg_mbs_reg_not_used = 0xFFFF; // Odd number 65535 is unused register
|
||||
|
||||
// Even data type is single (2-byte) register, Odd data type is double (4-byte) registers
|
||||
@ -482,7 +488,6 @@ void EnergyModbusLoop(void) {
|
||||
NrgMbsParam.mutex = 0;
|
||||
}
|
||||
|
||||
#ifdef USE_RULES
|
||||
uint32_t EnergyModbusReadRegisterInfo(JsonParserObject add_value, uint32_t reg_index) {
|
||||
// {"R":0,"T":0,"F":0}
|
||||
// {"R":[0,2,4],"T":0,"F":0}
|
||||
@ -581,11 +586,31 @@ bool EnergyModbusReadUserRegisters(JsonParserObject user_add_value, uint32_t add
|
||||
|
||||
return true;
|
||||
}
|
||||
#endif // USE_RULES
|
||||
|
||||
bool EnergyModbusReadRegisters(void) {
|
||||
String modbus = "";
|
||||
|
||||
#ifdef USE_UFILESYS
|
||||
const size_t file_size = ENERGY_MODBUS_MAX_FSIZE;
|
||||
char *modbus_file = (char*)calloc(file_size, 1);
|
||||
if (modbus_file) {
|
||||
if (TfsLoadFile(ENERGY_MODBUS_FILE, (uint8_t*)modbus_file, file_size -1)) {
|
||||
if (strlen(modbus_file) < ENERGY_MODBUS_MAX_FSIZE) {
|
||||
modbus = modbus_file;
|
||||
AddLog(LOG_LEVEL_DEBUG, PSTR("NRG: Load from file"));
|
||||
}
|
||||
}
|
||||
free(modbus_file);
|
||||
}
|
||||
#endif // USE_UFILESYS
|
||||
|
||||
#ifdef USE_RULES
|
||||
String modbus = RuleLoadFile("MODBUS");
|
||||
if (!modbus.length()) {
|
||||
modbus = RuleLoadFile("MODBUS");
|
||||
AddLog(LOG_LEVEL_DEBUG, PSTR("NRG: Load from rule"));
|
||||
}
|
||||
#endif // USE_RULES
|
||||
|
||||
if (!modbus.length()) { return false; } // File not found
|
||||
// AddLog(LOG_LEVEL_DEBUG, PSTR("NRG: File '%s'"), modbus.c_str());
|
||||
|
||||
@ -811,15 +836,13 @@ bool EnergyModbusReadRegisters(void) {
|
||||
NrgMbsParam.phase = -1;
|
||||
|
||||
return true;
|
||||
#endif // USE_RULES
|
||||
return false;
|
||||
}
|
||||
|
||||
bool EnergyModbusRegisters(void) {
|
||||
if (EnergyModbusReadRegisters()) {
|
||||
return true;
|
||||
}
|
||||
AddLog(LOG_LEVEL_INFO, PSTR("NRG: No valid modbus rule data"));
|
||||
AddLog(LOG_LEVEL_INFO, PSTR("NRG: No valid modbus data"));
|
||||
return false;
|
||||
}
|
||||
|
||||
|
Loading…