mirror of
https://github.com/arendst/Tasmota.git
synced 2025-07-24 11:16:34 +00:00
New feature Auto Clear Remote Temp for MiElHVAC (#22370)
* Add prohibit function for MiElHVAC Add Prohibit functions: * Power * Temperature * Mode and all combinations of this functions Updated VaneV names for better identify * Fixed Compressor and Operation for MiElHVAC Changed Widevane position name from ISEE to AUTO sam as in MELCLoud * Revert "Fixed Compressor and Operation for MiElHVAC" This reverts commit f0973c84d4915e776f715c0749a593efc6f55953. * New feature for MiElHVAC * Added Compressor map * Added Operation Power in Watts * Added Operation Energy in kWh * Changed Widevane position name from ISEE to AUTO, displays sam as in * Changed all map value to lover case MELCloud * New feature for MiElHVAC * Add device operation time in minutes * New feature Outdoor Temperature for MiElHVAC * Add Outdoor Temperature * New feature Compressor Frequency for MiElHVAC * Added Outdoor Temperature * Renamed internal properties due typo operating and oprating to operation * New feature Auto Clear Remote Temp for MiElHVAC * This PR add auto clear remote temperature function * This funcion is call on first run and after 10 sec the remote temperature stop refresh its value * Send manually Clear command is also available * change function name, small corrections * added auto clear time configurable using cmnd
This commit is contained in:
parent
ef3c061ecf
commit
27db263493
@ -44,11 +44,15 @@
|
||||
#define D_CMND_MIEL_HVAC_SETAIRDIRECTION "HVACSetAirDirection"
|
||||
#define D_CMND_MIEL_HVAC_SETPROHIBIT "HVACSetProhibit"
|
||||
#define D_CMND_MIEL_HVAC_REMOTETEMP "HVACRemoteTemp"
|
||||
#define D_CMND_MIEL_HVAC_REMOTETEMP_AUTO_CLEAR_TIME "HVACRemoteTempClearTime"
|
||||
|
||||
#include <TasmotaSerial.h>
|
||||
|
||||
/* from hvac */
|
||||
bool temp_type = false;
|
||||
bool remotetemp_clear = true;
|
||||
unsigned long remotetemp_auto_clear_time = 10000;
|
||||
unsigned long remotetemp_last_call_time = 0;
|
||||
|
||||
struct miel_hvac_header {
|
||||
uint8_t start;
|
||||
@ -944,6 +948,39 @@ miel_hvac_remotetemp_degc2old(long degc)
|
||||
MIEL_HVAC_REMOTETEMP_OLD_FACTOR);
|
||||
}
|
||||
|
||||
static void
|
||||
miel_hvac_auto_clear_remotetemp(void)
|
||||
{
|
||||
struct miel_hvac_softc *sc = miel_hvac_sc;
|
||||
struct miel_hvac_msg_remotetemp *rt = &sc->sc_remotetemp;
|
||||
uint8_t control = MIEL_HVAC_REMOTETEMP_CLR;
|
||||
long degc = 0;
|
||||
|
||||
memset(rt, 0, sizeof(*rt));
|
||||
rt->seven = 0x7;
|
||||
rt->control = control;
|
||||
rt->temp_old = miel_hvac_remotetemp_degc2old(degc);
|
||||
rt->temp = (degc + MIEL_HVAC_REMOTETEMP_OFFSET) * MIEL_HVAC_REMOTETEMP_OLD_FACTOR;
|
||||
|
||||
remotetemp_clear = false;
|
||||
}
|
||||
|
||||
static void
|
||||
miel_hvac_cmnd_remotetemp_auto_clear_time(void)
|
||||
{
|
||||
if (XdrvMailbox.data_len == 0)
|
||||
return;
|
||||
|
||||
unsigned long clear_time = strtoul(XdrvMailbox.data, nullptr, 10);
|
||||
if (clear_time == 0) {
|
||||
miel_hvac_respond_unsupported();
|
||||
return;
|
||||
}
|
||||
remotetemp_auto_clear_time = clear_time;
|
||||
|
||||
ResponseCmndNumber(remotetemp_auto_clear_time);
|
||||
}
|
||||
|
||||
static void
|
||||
miel_hvac_cmnd_remotetemp(void)
|
||||
{
|
||||
@ -960,6 +997,8 @@ miel_hvac_cmnd_remotetemp(void)
|
||||
degc = 0;
|
||||
|
||||
ResponseCmndChar_P("clear");
|
||||
remotetemp_clear = false;
|
||||
remotetemp_last_call_time = 0;
|
||||
} else {
|
||||
degc = strtol(XdrvMailbox.data, nullptr, 0);
|
||||
|
||||
@ -970,6 +1009,8 @@ miel_hvac_cmnd_remotetemp(void)
|
||||
degc = MIEL_HVAC_REMOTETEMP_MAX;
|
||||
|
||||
ResponseCmndNumber(degc);
|
||||
remotetemp_clear = true;
|
||||
remotetemp_last_call_time = millis();
|
||||
}
|
||||
|
||||
memset(rt, 0, sizeof(*rt));
|
||||
@ -1539,6 +1580,7 @@ static const char miel_hvac_cmnd_names[] PROGMEM =
|
||||
"|" D_CMND_MIEL_HVAC_SETAIRDIRECTION
|
||||
"|" D_CMND_MIEL_HVAC_SETPROHIBIT
|
||||
"|" D_CMND_MIEL_HVAC_REMOTETEMP
|
||||
"|" D_CMND_MIEL_HVAC_REMOTETEMP_AUTO_CLEAR_TIME
|
||||
#ifdef MIEL_HVAC_DEBUG
|
||||
"|" "HVACRequest"
|
||||
#endif
|
||||
@ -1554,6 +1596,7 @@ static void (*const miel_hvac_cmnds[])(void) PROGMEM = {
|
||||
&miel_hvac_cmnd_setairdirection,
|
||||
&miel_hvac_cmnd_setprohibit,
|
||||
&miel_hvac_cmnd_remotetemp,
|
||||
&miel_hvac_cmnd_remotetemp_auto_clear_time,
|
||||
#ifdef MIEL_HVAC_DEBUG
|
||||
&miel_hvac_cmnd_request,
|
||||
#endif
|
||||
@ -1592,6 +1635,9 @@ bool Xdrv44(uint32_t function) {
|
||||
case FUNC_EVERY_100_MSECOND:
|
||||
case FUNC_EVERY_200_MSECOND:
|
||||
case FUNC_EVERY_SECOND:
|
||||
if (remotetemp_clear && ((millis() - remotetemp_last_call_time) > remotetemp_auto_clear_time || remotetemp_last_call_time == 0)) {
|
||||
miel_hvac_auto_clear_remotetemp();
|
||||
}
|
||||
break;
|
||||
|
||||
case FUNC_JSON_APPEND:
|
||||
|
Loading…