make IRHVAC send incremental changes. (#18310)
This change will allow mqtt messages simpler by allowing something like `publish cmnd/ir-bridge/IRHVAC {"Power": "On"}`. The simpler format is required for working with mqtt clients like iotMQTTPanel or similar on android. Limitations: - Requires full message be sent at-least once. I work around this with a `system#boot` rule - Gets messy with multiple devices. I have only one AC per room, and this doesn't doesn't interfere with other IR devices. TODO: - [ ] Change the build flag `INCREMENTAL_IRAC`to a `SetOption` - [ ] Persist `irac_prev_state` across reboots. - [ ] Support multiple devices.
This commit is contained in:
parent
63cc575c8b
commit
2f616eef2c
@ -561,6 +561,7 @@
|
||||
#define D_JSON_IRHVAC_STATE_MODE_SEND_ONLY "SendOnly"
|
||||
#define D_JSON_IRHVAC_STATE_MODE_STORE_ONLY "StoreOnly"
|
||||
#define D_JSON_IRHVAC_STATE_MODE_SEND_STORE "SendStore"
|
||||
#define D_JSON_IRHVAC_INCREMENTAL "Incremental"
|
||||
#define D_JSON_IRRECEIVED "IrReceived"
|
||||
|
||||
// Commands xdrv_06_snfbridge.ino
|
||||
|
@ -128,6 +128,8 @@ protected:
|
||||
// some ACs send toggle messages rather than state. we need to help IRremoteESP8266 keep track of the state
|
||||
// have a flag that is a variable, can be later used to convert this functionality to an option (as in SetOptionXX)
|
||||
bool irhvac_stateful = true;
|
||||
bool irhvac_incremental = true;
|
||||
|
||||
stdAc::state_t irac_prev_state; // this implementations only keeps one state so if you use a single tasmota-ir device to command more than one AC it might not work
|
||||
|
||||
// different modes on how to handle state when sending HVAC commands. needed for ACs with a differential/toggle protocol.
|
||||
@ -438,6 +440,8 @@ const stdAc::fanspeed_t IrHvacFanSpeed[] PROGMEM = { stdAc::fanspeed_t::kAuto,
|
||||
|
||||
uint32_t IrRemoteCmndIrHvacJson(void)
|
||||
{
|
||||
// state is initialized to the IRremoteESP8266's state_t defaults anyway
|
||||
// https://github.com/crankyoldgit/IRremoteESP8266/blob/v2.8.4/src/IRsend.h#L97-L116
|
||||
stdAc::state_t state;
|
||||
|
||||
//AddLog(LOG_LEVEL_DEBUG, PSTR("IRHVAC: Received %s"), XdrvMailbox.data);
|
||||
@ -445,28 +449,13 @@ uint32_t IrRemoteCmndIrHvacJson(void)
|
||||
JsonParserObject root = parser.getRootObject();
|
||||
if (!root) { return IE_INVALID_JSON; }
|
||||
|
||||
// from: https://github.com/crankyoldgit/IRremoteESP8266/blob/master/examples/CommonAcControl/CommonAcControl.ino
|
||||
state.protocol = decode_type_t::UNKNOWN;
|
||||
state.model = 1; // Some A/C's have different models. Let's try using just 1.
|
||||
state.command = stdAc::ac_command_t::kControlCommand;
|
||||
state.mode = stdAc::opmode_t::kAuto; // Run in cool mode initially.
|
||||
state.power = false; // Initially start with the unit off.
|
||||
state.celsius = true; // Use Celsius for units of temp. False = Fahrenheit
|
||||
state.degrees = 21.0f; // 21 degrees.
|
||||
state.fanspeed = stdAc::fanspeed_t::kMedium; // Start with the fan at medium.
|
||||
state.swingv = stdAc::swingv_t::kOff; // Don't swing the fan up or down.
|
||||
state.swingh = stdAc::swingh_t::kOff; // Don't swing the fan left or right.
|
||||
state.light = false; // Turn off any LED/Lights/Display that we can.
|
||||
state.beep = false; // Turn off any beep from the A/C if we can.
|
||||
state.econo = false; // Turn off any economy modes if we can.
|
||||
state.filter = false; // Turn off any Ion/Mold/Health filters if we can.
|
||||
state.turbo = false; // Don't use any turbo/powerful/etc modes.
|
||||
state.quiet = false; // Don't use any quiet/silent/etc modes.
|
||||
state.sleep = -1; // Don't set any sleep time or modes.
|
||||
state.clean = false; // Turn off any Cleaning options if we can.
|
||||
state.clock = -1; // Don't set any current time if we can avoid it.
|
||||
state.iFeel = false;
|
||||
state.sensorTemperature = kNoTempValue; // Don't set any sensor (ambient) temperature if not provided
|
||||
bool incremental = strToBool(root[PSTR(D_JSON_IRHVAC_INCREMENTAL)], false);
|
||||
|
||||
// TODO: add support for storing multiple states
|
||||
if (incremental)
|
||||
{
|
||||
state = irac_prev_state;
|
||||
}
|
||||
|
||||
JsonParserToken val;
|
||||
if (val = root[PSTR(D_JSON_IRHVAC_VENDOR)]) { state.protocol = strToDecodeType(val.getStr()); }
|
||||
@ -495,8 +484,8 @@ uint32_t IrRemoteCmndIrHvacJson(void)
|
||||
// AddLog(LOG_LEVEL_DEBUG, PSTR("model %d, mode %d, fanspeed %d, swingv %d, swingh %d"),
|
||||
// state.model, state.mode, state.fanspeed, state.swingv, state.swingh);
|
||||
|
||||
// if and how we should handle the state for IRremote
|
||||
StateModes stateMode = StateModes::SEND_ONLY; // default
|
||||
StateModes stateMode = incremental ? StateModes::SEND_STORE : StateModes::SEND_ONLY;
|
||||
|
||||
if (irhvac_stateful && (val = root[PSTR(D_JSON_IRHVAC_STATE_MODE)])) { stateMode = strToStateMode(val, stateMode); }
|
||||
|
||||