Fix for iem3155 wattmeter - CRC error, Power unit error, Energy total number type mismatch
This commit is contained in:
parent
01827670e8
commit
35698dbe64
@ -778,6 +778,7 @@
|
||||
//#define USE_IEM3000 // Add support for Schneider Electric iEM3000-Modbus series energy monitor (+0k8 code)
|
||||
#define IEM3000_SPEED 19200 // iEM3000-Modbus RS485 serial speed (default: 19200 baud)
|
||||
#define IEM3000_ADDR 1 // iEM3000-Modbus modbus address (default: 0x01)
|
||||
// #ifdef IEM3000_IEM3155 //Compatibility fix for Iem3155 (changes Power and Energy total readout)
|
||||
//#define USE_WE517 // Add support for Orno WE517-Modbus energy monitor (+1k code)
|
||||
|
||||
// -- Low level interface devices -----------------
|
||||
|
@ -51,9 +51,19 @@ const uint16_t Iem3000_start_addresses[] {
|
||||
0x0bef, // 7 . IEM3000_P2_POWER (2/Float32) [KW] Active Power Phase 2
|
||||
0x0bf1, // 8 . IEM3000_P3_POWER (2/Float32) [KW] Active Power Phase 3
|
||||
0x0c25, // 9 . IEM3000_FREQUENCY (2/Float32) [Hz] Frequency
|
||||
#ifdef IEM3000_IEM3155
|
||||
0xb02b, // 10 . IEM3000_TOTAL_ACTIVE (2/Float32) [Wh] Total Active Energy Import
|
||||
#else
|
||||
0xb02b, // 10 . IEM3000_TOTAL_ACTIVE (4/Int64) [Wh] Total Active Energy Import
|
||||
#endif
|
||||
};
|
||||
|
||||
#ifdef IEM3000_IEM3155
|
||||
#define FLOAT_ParamLimit 11
|
||||
#else
|
||||
#define FLOAT_ParamLimit 10
|
||||
#endif
|
||||
|
||||
struct IEM3000 {
|
||||
uint8_t read_state = 0;
|
||||
uint8_t send_retry = 0;
|
||||
@ -65,12 +75,12 @@ void IEM3000Every250ms(void)
|
||||
{
|
||||
bool data_ready = Iem3000Modbus->ReceiveReady();
|
||||
uint8_t reg_count = 4;
|
||||
if (Iem3000.read_state < 10) {
|
||||
if (Iem3000.read_state < FLOAT_ParamLimit) {
|
||||
reg_count = 2;
|
||||
}
|
||||
|
||||
if (data_ready) {
|
||||
uint8_t buffer[14]; // At least 5 + sizeof(int64_t) = 13
|
||||
uint8_t buffer[16]; // At least 5 + sizeof(int64_t) = 13
|
||||
|
||||
uint32_t error = Iem3000Modbus->ReceiveBuffer(buffer, reg_count);
|
||||
AddLogBuffer(LOG_LEVEL_DEBUG_MORE, buffer, Iem3000Modbus->ReceiveCount());
|
||||
@ -85,7 +95,7 @@ void IEM3000Every250ms(void)
|
||||
// 01 04 04 43 66 33 34 1B 38 = 230.2 Volt
|
||||
float value;
|
||||
int64_t value64;
|
||||
if(Iem3000.read_state >= 0 && Iem3000.read_state < 10) {
|
||||
if(Iem3000.read_state >= 0 && Iem3000.read_state < FLOAT_ParamLimit) {
|
||||
((uint8_t*)&value)[3] = buffer[3]; // Get float values
|
||||
((uint8_t*)&value)[2] = buffer[4];
|
||||
((uint8_t*)&value)[1] = buffer[5];
|
||||
@ -127,15 +137,27 @@ void IEM3000Every250ms(void)
|
||||
break;
|
||||
|
||||
case 6:
|
||||
#ifdef IEM3000_IEM3155
|
||||
Energy.active_power[0] = value*1000;
|
||||
#else
|
||||
Energy.active_power[0] = value;
|
||||
#endif
|
||||
break;
|
||||
|
||||
case 7:
|
||||
#ifdef IEM3000_IEM3155
|
||||
Energy.active_power[1] = value*1000;
|
||||
#else
|
||||
Energy.active_power[1] = value;
|
||||
#endif
|
||||
break;
|
||||
|
||||
case 8:
|
||||
#ifdef IEM3000_IEM3155
|
||||
Energy.active_power[2] = value*1000;
|
||||
#else
|
||||
Energy.active_power[2] = value;
|
||||
#endif
|
||||
break;
|
||||
|
||||
case 9:
|
||||
@ -143,7 +165,11 @@ void IEM3000Every250ms(void)
|
||||
break;
|
||||
|
||||
case 10:
|
||||
#ifdef IEM3000_IEM3155
|
||||
EnergyUpdateTotal(value, true);
|
||||
#else
|
||||
EnergyUpdateTotal(value64 * 0.001f, true); // 1125 => 1.125
|
||||
#endif
|
||||
break;
|
||||
}
|
||||
|
||||
|