[Solax X1] fix apparent power (#17833)

U*I from inverter is not valid for apparent power as U*I could be lower than active power
This commit is contained in:
SteWers 2023-01-31 22:23:31 +01:00 committed by GitHub
parent ae8041140f
commit 438b235dc8
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23

View File

@ -2,7 +2,7 @@
xnrg_12_solaxX1.ino - Solax X1 inverter RS485 support for Tasmota
Copyright (C) 2021 by Pablo Zerón
Copyright (C) 2022 by Stefan Wershoven
Copyright (C) 2023 by Stefan Wershoven
This program is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
@ -295,6 +295,7 @@ void solaxX1_250MSecond(void) // Every 250 milliseconds
Energy->voltage[0] = ((DataRead[23] << 8) | DataRead[24]) * 0.1f; // AC Voltage
Energy->frequency[0] = ((DataRead[25] << 8) | DataRead[26]) * 0.01f; // AC Frequency
Energy->active_power[0] = ((DataRead[27] << 8) | DataRead[28]); // AC Power
Energy->apparent_power[0] = Energy->active_power[0]; // U*I from inverter is not valid for apparent power; U*I could be lower than active power
//temporal = (float)((DataRead[29] << 8) | DataRead[30]) * 0.1f; // Not Used
Energy->import_active[0] = ((DataRead[31] << 24) | (DataRead[32] << 16) | (DataRead[33] << 8) | DataRead[34]) * 0.1f; // Energy Total
solaxX1.runtime_total = (DataRead[35] << 24) | (DataRead[36] << 16) | (DataRead[37] << 8) | DataRead[38]; // Work Time Total