Add VINDRIGTNING user compile time control

Add user compile time control over VINDRIGTNING undocumented values
This commit is contained in:
Theo Arends 2021-09-01 17:32:25 +02:00
parent 2b0845a697
commit 44c0059a88
2 changed files with 42 additions and 39 deletions

View File

@ -746,6 +746,8 @@
//#define USE_TFMINIPLUS // Add support for TFmini Plus (TFmini, TFmini-S) LiDAR modules via UART interface (+0k8)
//#define USE_HRG15 // Add support for Hydreon RG-15 Solid State Rain sensor (+1k5 code)
//#define USE_VINDRIKTNING // Add support for IKEA VINDRIKTNING particle concentration sensor (+0k6 code)
// #define VINDRIKTNING_SHOW_PM1 // Display undocumented/supposed PM1.0 values
// #define VINDRIKTNING_SHOW_PM10 // Display undocumented/supposed PM10 values
// -- Power monitoring sensors --------------------
#define USE_ENERGY_SENSOR // Add support for Energy Monitors (+14k code)

View File

@ -27,7 +27,8 @@
#define XSNS_91 91
//#define XSNS_91_XTRA_INFO // Display unverified data for PM1.0 and PM10
//#define VINDRIKTNING_SHOW_PM1 // Display undocumented/supposed PM1.0 values
//#define VINDRIKTNING_SHOW_PM10 // Display undocumented/supposed PM10 values
#include <TasmotaSerial.h>
@ -36,11 +37,13 @@
TasmotaSerial *VindriktningSerial;
struct VINDRIKTNING {
uint16_t pm2_5 = 0;
#ifdef XSNS_91_XTRA_INFO
#ifdef VINDRIKTNING_SHOW_PM1
uint16_t pm1_0 = 0;
#endif // VINDRIKTNING_SHOW_PM1
uint16_t pm2_5 = 0;
#ifdef VINDRIKTNING_SHOW_PM10
uint16_t pm10 = 0;
#endif // XSNS_91_XTRA_INFO
#endif // VINDRIKTNING_SHOW_PM10
uint8_t type = 1;
uint8_t valid = 0;
bool discovery_triggered = false;
@ -77,10 +80,12 @@ bool VindriktningReadData(void) {
// 16 11 0b 00 00 00 0c 00 00 03 cb 00 00 00 0c 01 00 00 00 e7
// |pm2_5| |pm1_0| |pm10 | | CRC |
Vindriktning.pm2_5 = (buffer[5] << 8) | buffer[6];
#ifdef XSNS_91_XTRA_INFO
#ifdef VINDRIKTNING_SHOW_PM1
Vindriktning.pm1_0 = (buffer[9] << 8) | buffer[10];
#endif // VINDRIKTNING_SHOW_PM1
#ifdef VINDRIKTNING_SHOW_PM10
Vindriktning.pm10 = (buffer[13] << 8) | buffer[14];
#endif // XSNS_91_XTRA_INFO
#endif // VINDRIKTNING_SHOW_PM10
if (!Vindriktning.discovery_triggered) {
TasmotaGlobal.discovery_counter = 1; // force TasDiscovery()
@ -114,60 +119,56 @@ void VindriktningInit(void) {
}
}
#ifdef XSNS_91_XTRA_INFO
#ifdef USE_WEBSERVER
const char HTTP_VINDRIKTNING_SNS[] PROGMEM =
"{s}VINDRIKTNING " D_ENVIRONMENTAL_CONCENTRATION " 1.0 " D_UNIT_MICROMETER "{m}%d " D_UNIT_MICROGRAM_PER_CUBIC_METER "{e}"
"{s}VINDRIKTNING " D_ENVIRONMENTAL_CONCENTRATION " 2.5 " D_UNIT_MICROMETER "{m}%d " D_UNIT_MICROGRAM_PER_CUBIC_METER "{e}"
#ifdef VINDRIKTNING_SHOW_PM1
const char HTTP_VINDRIKTNING_SNS_PM1[] PROGMEM =
"{s}VINDRIKTNING " D_ENVIRONMENTAL_CONCENTRATION " 1 " D_UNIT_MICROMETER "{m}%d " D_UNIT_MICROGRAM_PER_CUBIC_METER "{e}"; // {s} = <tr><th>, {m} = </th><td>, {e} = </td></tr>
#endif // VINDRIKTNING_SHOW_PM1
const char HTTP_VINDRIKTNING_SNS_PM2_5[] PROGMEM =
"{s}VINDRIKTNING " D_ENVIRONMENTAL_CONCENTRATION " 2.5 " D_UNIT_MICROMETER "{m}%d " D_UNIT_MICROGRAM_PER_CUBIC_METER "{e}"; // {s} = <tr><th>, {m} = </th><td>, {e} = </td></tr>
#ifdef VINDRIKTNING_SHOW_PM10
const char HTTP_VINDRIKTNING_SNS_PM10[] PROGMEM =
"{s}VINDRIKTNING " D_ENVIRONMENTAL_CONCENTRATION " 10 " D_UNIT_MICROMETER "{m}%d " D_UNIT_MICROGRAM_PER_CUBIC_METER "{e}"; // {s} = <tr><th>, {m} = </th><td>, {e} = </td></tr>
#endif // VINDRIKTNING_SHOW_PM10
#endif // USE_WEBSERVER
void VindriktningShow(bool json) {
if (Vindriktning.valid) {
if (json) {
ResponseAppend_P(PSTR(",\"VINDRIKTNING\":{\"PM1\":%d,\"PM2.5\":%d,\"PM10\":%d}"), Vindriktning.pm1_0, Vindriktning.pm2_5, Vindriktning.pm10);
ResponseAppend_P(PSTR(",\"VINDRIKTNING\":{"));
#ifdef VINDRIKTNING_SHOW_PM1
ResponseAppend_P(PSTR("\"PM1\":%d,"), Vindriktning.pm1_0);
#endif // VINDRIKTNING_SHOW_PM1
ResponseAppend_P(PSTR("\"PM2.5\":%d"), Vindriktning.pm2_5);
#ifdef VINDRIKTNING_SHOW_PM10
ResponseAppend_P(PSTR(",\"PM10\":%d"), Vindriktning.pm10);
#endif // VINDRIKTNING_SHOW_PM10
ResponseJsonEnd();
#ifdef USE_DOMOTICZ
if (0 == TasmotaGlobal.tele_period) {
#ifdef VINDRIKTNING_SHOW_PM1
DomoticzSensor(DZ_COUNT, Vindriktning.pm1_0); // PM1.0
#endif // VINDRIKTNING_SHOW_PM1
DomoticzSensor(DZ_VOLTAGE, Vindriktning.pm2_5); // PM2.5
#ifdef VINDRIKTNING_SHOW_PM10
DomoticzSensor(DZ_CURRENT, Vindriktning.pm10); // PM10
#endif // VINDRIKTNING_SHOW_PM10
}
#endif // USE_DOMOTICZ
#ifdef USE_WEBSERVER
} else {
WSContentSend_PD(HTTP_VINDRIKTNING_SNS, Vindriktning.pm1_0, Vindriktning.pm2_5, Vindriktning.pm10);
#ifdef VINDRIKTNING_SHOW_PM1
WSContentSend_PD(HTTP_VINDRIKTNING_SNS_PM1, Vindriktning.pm1_0);
#endif // VINDRIKTNING_SHOW_PM1
WSContentSend_PD(HTTP_VINDRIKTNING_SNS_PM2_5, Vindriktning.pm2_5);
#ifdef VINDRIKTNING_SHOW_PM10
WSContentSend_PD(HTTP_VINDRIKTNING_SNS_PM10, Vindriktning.pm10);
#endif // VINDRIKTNING_SHOW_PM10
#endif // USE_WEBSERVER
}
}
}
#else // No XSNS_91_XTRA_INFO
#ifdef USE_WEBSERVER
const char HTTP_VINDRIKTNING_SNS[] PROGMEM =
"{s}VINDRIKTNING " D_ENVIRONMENTAL_CONCENTRATION " 2.5 " D_UNIT_MICROMETER "{m}%d " D_UNIT_MICROGRAM_PER_CUBIC_METER "{e}";
#endif // USE_WEBSERVER
void VindriktningShow(bool json) {
if (Vindriktning.valid) {
if (json) {
ResponseAppend_P(PSTR(",\"VINDRIKTNING\":{\"PM2.5\":%d}"), Vindriktning.pm2_5);
#ifdef USE_DOMOTICZ
if (0 == TasmotaGlobal.tele_period) {
DomoticzSensor(DZ_VOLTAGE, Vindriktning.pm2_5); // PM2.5
}
#endif // USE_DOMOTICZ
#ifdef USE_WEBSERVER
} else {
WSContentSend_PD(HTTP_VINDRIKTNING_SNS, Vindriktning.pm2_5);
#endif // USE_WEBSERVER
}
}
}
#endif // XSNS_91_XTRA_INFO
/*********************************************************************************************\
* Interface
\*********************************************************************************************/