mirror of
https://github.com/arendst/Tasmota.git
synced 2025-04-24 14:57:16 +00:00
missing "" around UV Index test in json
Fixed the missing "" around the UV Index test in json Old one: "VEML6070":{"UvLevel":6212,"UvIndex":8.32,"UvIndexText":Danger,"UvPower":0.208}} New one: "VEML6070":{"UvLevel":6212,"UvIndex":8.32,"UvIndexText":"Danger","UvPower":0.208}} Now it works. I have no mqtt system running so i did not know that this would happen. Possible i have to build up one system.
This commit is contained in:
parent
70cdb7e19b
commit
461fed6290
@ -31,6 +31,9 @@
|
||||
Version Date Action Description
|
||||
--------------------------------------------------------------------------------------------
|
||||
|
||||
1.0.0.3 20181006 fixed - missing "" around the UV Index text
|
||||
- thanks to Lisa she had tested it on here mqtt system.
|
||||
--
|
||||
1.0.0.2 20180928 tests - same as in version 1.0.0.1
|
||||
cleaned - source code
|
||||
changed - snprintf_P for json and web server output
|
||||
@ -77,9 +80,9 @@
|
||||
- show not only the UV Power value in W/m2, possible a @define value to show it as joule value
|
||||
- add a #define to select how many characters are shown benhind the decimal point for the UV Index
|
||||
---
|
||||
1.0.0.0 20180912 started - further development by mike2nl - https://github.com/mike2nl/Sonoff-Tasmota
|
||||
forked - from arendst/tasmota - https://github.com/arendst/Sonoff-Tasmota
|
||||
base - code base from arendst too
|
||||
1.0.0.0 20180912 started - further development by mike2nl - https://github.com/mike2nl/Sonoff-Tasmota
|
||||
forked - from arendst/tasmota - https://github.com/arendst/Sonoff-Tasmota
|
||||
base - code base from arendst too
|
||||
|
||||
*/
|
||||
|
||||
@ -168,11 +171,11 @@ void Veml6070EverySecond(void)
|
||||
{
|
||||
// all = 10..15[ms]
|
||||
if (11 == (uptime %100)) {
|
||||
Veml6070ModeCmd(1); // on = 1[ms], wakeup the UV sensor
|
||||
Veml6070ModeCmd(1); // on = 1[ms], wakeup the UV sensor
|
||||
Veml6070Detect(); // 1[ms], check for sensor and init with IT time
|
||||
Veml6070ModeCmd(0); // off = 5[ms], suspend the UV sensor
|
||||
} else {
|
||||
Veml6070ModeCmd(1); // 1[ms], wakeup the UV sensor
|
||||
Veml6070ModeCmd(1); // 1[ms], wakeup the UV sensor
|
||||
uvlevel = Veml6070ReadUv(); // 1..2[ms], get UV raw values
|
||||
uvrisk = Veml6070UvRiskLevel(uvlevel); // 0..1[ms], get UV risk level
|
||||
uvpower = Veml6070UvPower(uvrisk); // 2[ms], get UV power in W/m2
|
||||
@ -277,10 +280,10 @@ void Veml6070Show(boolean json)
|
||||
dtostrfd(uvpower, 3, str_uvpower);
|
||||
if (json) {
|
||||
#ifdef USE_VEML6070_SHOW_RAW
|
||||
snprintf_P(mqtt_data, sizeof(mqtt_data), PSTR("%s,\"%s\":{\"" D_JSON_UV_LEVEL "\":%s,\"" D_JSON_UV_INDEX "\":%s,\"" D_JSON_UV_INDEX_TEXT "\":%s,\"" D_JSON_UV_POWER "\":%s}"),
|
||||
snprintf_P(mqtt_data, sizeof(mqtt_data), PSTR("%s,\"%s\":{\"" D_JSON_UV_LEVEL "\":%s,\"" D_JSON_UV_INDEX "\":%s,\"" D_JSON_UV_INDEX_TEXT "\":\"%s\",\"" D_JSON_UV_POWER "\":%s}"),
|
||||
mqtt_data, veml6070_name, str_uvlevel, str_uvrisk, str_uvrisk_text, str_uvpower);
|
||||
#else
|
||||
snprintf_P(mqtt_data, sizeof(mqtt_data), PSTR("%s,\"%s\":{\"" D_JSON_UV_INDEX "\":%s,\"" D_JSON_UV_INDEX_TEXT "\":%s,\"" D_JSON_UV_POWER "\":%s}"),
|
||||
snprintf_P(mqtt_data, sizeof(mqtt_data), PSTR("%s,\"%s\":{\"" D_JSON_UV_INDEX "\":%s,\"" D_JSON_UV_INDEX_TEXT "\":\"%s\",\"" D_JSON_UV_POWER "\":%s}"),
|
||||
mqtt_data, veml6070_name, str_uvrisk, str_uvrisk_text, str_uvpower);
|
||||
#endif // USE_VEML6070_SHOW_RAW
|
||||