Add shelly EM default phase calibration
Add shelly EM default phase calibration (#16486)
This commit is contained in:
parent
da623701d7
commit
645b9d13d6
@ -35,7 +35,7 @@
|
|||||||
* Optionally allowing users to tweak calibration registers:
|
* Optionally allowing users to tweak calibration registers:
|
||||||
* - In addition to possible rules add a rule containing the calib.dat string like:
|
* - In addition to possible rules add a rule containing the calib.dat string like:
|
||||||
* - rule3 on file#calib.dat do {"angles":{"angle0":180,"angle1":176}} endon
|
* - rule3 on file#calib.dat do {"angles":{"angle0":180,"angle1":176}} endon
|
||||||
* - rule3 on file#calib.dat do {"rms":{"current_a":4194303,"current_b":4194303,"voltage":1613194},"angles":{"angle0":0,"angle1":0},"powers":{"totactive":{"a":2723574,"b":2723574},"apparent":{"a":2723574,"b":2723574},"reactive":{"a":2723574,"b":2723574}}} endon
|
* - rule3 on file#calib.dat do {"rms":{"current_a":4194303,"current_b":4194303,"voltage":1613194},"angles":{"angle0":200,"angle1":200},"powers":{"totactive":{"a":2723574,"b":2723574},"apparent":{"a":2723574,"b":2723574},"reactive":{"a":2723574,"b":2723574}}} endon
|
||||||
* - Restart Tasmota and obeserve that the results seem calibrated as Tasmota now uses the information from calib.dat
|
* - Restart Tasmota and obeserve that the results seem calibrated as Tasmota now uses the information from calib.dat
|
||||||
* To restore standard calibration using commands like VoltSet remove above entry from rule3
|
* To restore standard calibration using commands like VoltSet remove above entry from rule3
|
||||||
\*********************************************************************************************/
|
\*********************************************************************************************/
|
||||||
@ -55,7 +55,9 @@
|
|||||||
|
|
||||||
// Default calibration parameters can be overridden by a rule as documented above.
|
// Default calibration parameters can be overridden by a rule as documented above.
|
||||||
#define ADE7953_GAIN_DEFAULT 4194304 // = 0x400000 range 2097152 (min) to 6291456 (max)
|
#define ADE7953_GAIN_DEFAULT 4194304 // = 0x400000 range 2097152 (min) to 6291456 (max)
|
||||||
#define ADE7953_PHCAL_DEFAULT 0 // = range -383 to 383
|
|
||||||
|
#define ADE7953_PHCAL_DEFAULT 0 // = range -383 to 383 - Default phase calibration for Shunts
|
||||||
|
#define ADE7953_PHCAL_DEFAULT_CT 200 // = range -383 to 383 - Default phase calibration for Current Transformers (Shelly EM)
|
||||||
|
|
||||||
enum Ade7953Models { ADE7953_SHELLY_25, ADE7953_SHELLY_EM, ADE7953_SHELLY_PLUS_2PM };
|
enum Ade7953Models { ADE7953_SHELLY_25, ADE7953_SHELLY_EM, ADE7953_SHELLY_PLUS_2PM };
|
||||||
|
|
||||||
@ -530,7 +532,7 @@ void Ade7953Defaults(void) {
|
|||||||
if (i < sizeof(Ade7953CalibRegs)/sizeof(uint16_t) -2) {
|
if (i < sizeof(Ade7953CalibRegs)/sizeof(uint16_t) -2) {
|
||||||
Ade7953.calib_data[i] = ADE7953_GAIN_DEFAULT;
|
Ade7953.calib_data[i] = ADE7953_GAIN_DEFAULT;
|
||||||
} else {
|
} else {
|
||||||
Ade7953.calib_data[i] = ADE7953_PHCAL_DEFAULT;
|
Ade7953.calib_data[i] = (ADE7953_SHELLY_EM == Ade7953.model) ? ADE7953_PHCAL_DEFAULT_CT : ADE7953_PHCAL_DEFAULT;
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|