New feature operation time for MiElHVAC (#22334)
* Add prohibit function for MiElHVAC Add Prohibit functions: * Power * Temperature * Mode and all combinations of this functions Updated VaneV names for better identify * Fixed Compressor and Operation for MiElHVAC Changed Widevane position name from ISEE to AUTO sam as in MELCLoud * Revert "Fixed Compressor and Operation for MiElHVAC" This reverts commit f0973c84d4915e776f715c0749a593efc6f55953. * New feature for MiElHVAC * Added Compressor map * Added Operation Power in Watts * Added Operation Energy in kWh * Changed Widevane position name from ISEE to AUTO, displays sam as in * Changed all map value to lover case MELCloud * New feature for MiElHVAC * Add device operation time in minutes
This commit is contained in:
parent
2b6acff4f4
commit
6b094ede16
@ -87,11 +87,15 @@ struct miel_hvac_data_roomtemp {
|
||||
uint8_t temp;
|
||||
uint8_t _pad2[2];
|
||||
uint8_t temp05;
|
||||
uint8_t settemp;
|
||||
uint8_t _pad3[3];
|
||||
uint8_t opratingtime;
|
||||
uint8_t opratingtime1;
|
||||
uint8_t opratingtime2;
|
||||
};
|
||||
|
||||
struct miel_hvac_data_status {
|
||||
uint8_t _pad1[2];
|
||||
uint8_t _pad2[1];
|
||||
uint8_t _pad1[3];
|
||||
uint8_t compressor;
|
||||
#define MIEL_HVAC_STATUS_COMPRESSOR_OFF 0x00
|
||||
#define MIEL_HVAC_STATUS_COMPRESSOR_ON 0x01
|
||||
@ -135,6 +139,10 @@ CTASSERT(offsetof(struct miel_hvac_data, data.settings.airdirection) == 14);
|
||||
|
||||
CTASSERT(offsetof(struct miel_hvac_data, data.roomtemp.temp) == 3);
|
||||
CTASSERT(offsetof(struct miel_hvac_data, data.roomtemp.temp05) == 6);
|
||||
CTASSERT(offsetof(struct miel_hvac_data, data.roomtemp.settemp) == 7);
|
||||
CTASSERT(offsetof(struct miel_hvac_data, data.roomtemp.opratingtime) == 11);
|
||||
CTASSERT(offsetof(struct miel_hvac_data, data.roomtemp.opratingtime1) == 12);
|
||||
CTASSERT(offsetof(struct miel_hvac_data, data.roomtemp.opratingtime2) == 13);
|
||||
|
||||
CTASSERT(offsetof(struct miel_hvac_data, data.status.compressor) == 4);
|
||||
CTASSERT(offsetof(struct miel_hvac_data, data.status.operationpower) == 5);
|
||||
@ -1345,6 +1353,17 @@ miel_hvac_sensor(struct miel_hvac_softc *sc)
|
||||
}
|
||||
ResponseAppend_P(PSTR(",\"Temperature\":\"%s\""),
|
||||
room_temp);
|
||||
|
||||
uint32_t combined_time = ((uint32_t)rt->opratingtime << 16) | ((uint32_t)rt->opratingtime1 << 8) | (uint32_t)rt->opratingtime2;
|
||||
float operationtime_in_min = (float)combined_time;
|
||||
char operationtime[33];
|
||||
dtostrf(operationtime_in_min, 1, 0, operationtime);
|
||||
ResponseAppend_P(PSTR(",\"OperationTime\":\"%s\""),
|
||||
operationtime);
|
||||
|
||||
ResponseAppend_P(PSTR(",\"RoomTemp\":\"%s\""),
|
||||
ToHex_P((uint8_t *)&sc->sc_temp, sizeof(sc->sc_temp),
|
||||
hex, sizeof(hex)));
|
||||
}
|
||||
|
||||
if (sc->sc_status.type != 0) {
|
||||
@ -1370,15 +1389,7 @@ miel_hvac_sensor(struct miel_hvac_softc *sc)
|
||||
dtostrfd((float)operationenergy_in_kWh, 1, operationenergy);
|
||||
ResponseAppend_P(PSTR(",\"OperationEnergy\":\"%s\""),
|
||||
operationenergy);
|
||||
}
|
||||
|
||||
if (sc->sc_temp.type != 0) {
|
||||
ResponseAppend_P(PSTR(",\"RoomTemp\":\"%s\""),
|
||||
ToHex_P((uint8_t *)&sc->sc_temp, sizeof(sc->sc_temp),
|
||||
hex, sizeof(hex)));
|
||||
}
|
||||
|
||||
if (sc->sc_status.type != 0) {
|
||||
ResponseAppend_P(PSTR(",\"Status\":\"%s\""),
|
||||
ToHex_P((uint8_t *)&sc->sc_status, sizeof(sc->sc_status),
|
||||
hex, sizeof(hex)));
|
||||
|