@ -113,8 +113,16 @@ enum NeoPoolRegister {
// GLOBAL page (0x02xx)
MBF_CELL_RUNTIME_LOW = 0x0206, // 0x0206* undocumented - cell runtime (32 bit) - low word
MBF_CELL_RUNTIME_HIGH = 0x0207, // 0x0207* undocumented - cell runtime (32 bit) - high word
MBF_CELL_RUNTIME_HIGH, // 0x0207* undocumented - cell runtime (32 bit) - high word
MBF_CELL_RUNTIME_PART_LOW, // 0x0208 undocumented - cell part runtime (32 bit) - low word
MBF_CELL_RUNTIME_PART_HIGH, // 0x0209 undocumented - cell part runtime (32 bit) - high word
MBF_BOOST_CTRL = 0x020C, // 0x020C undocumented - 0x0000 = Boost Off, 0x05A0 = Boost with redox ctrl, 0x85A0 = Boost without redox ctrl
MBF_CELL_RUNTIME_POLA_LOW = 0x0214, // 0x0214 undocumented - cell runtime polarity A (32 bit) - low word
MBF_CELL_RUNTIME_POLA_HIGH, // 0x0215 undocumented - cell runtime polarity A (32 bit) - high word
MBF_CELL_RUNTIME_POLB_LOW, // 0x0216 undocumented - cell runtime polarity B (32 bit) - low word
MBF_CELL_RUNTIME_POLB_HIGH, // 0x0217 undocumented - cell runtime polarity B (32 bit) - high word
MBF_CELL_RUNTIME_POL_CHANGES_LOW, // 0x0218 undocumented - cell runtime polarity changes (32 bit) - low word
MBF_CELL_RUNTIME_POL_CHANGES_HIGH, // 0x0219 undocumented - cell runtime polarity changes (32 bit) - high word
MBF_HIDRO_MODULE_VERSION = 0x0280, // 0x0280 undocumented - Hydrolysis module version
MBF_HIDRO_MODULE_CONNECTIVITY = 0x0281, // 0x0281 undocumented - Hydrolysis module connection quality (in myriad: 0..10000)
MBF_SET_MANUAL_CTRL = 0x0289, // 0x0289 undocumented - write a 1 before manual control MBF_RELAY_STATE, after done write 0 and do MBF_EXEC
@ -542,6 +550,16 @@ enum NeoPoolConstAndBitMask {
MBMSK_VOE_SHOW_PNEUMATIC_VALVE = 0x0001, // 0 Shows the pneumatic valve
MBMSK_VOE_HIDE_AUX_REL_DEPENDENCY = 0x0002, // 1 Hides the auxiliary relay dependency
MBMSK_VOE_SHOW_BESGO_NAME = 0x0004, // 2 Show “Besgo” instead of “Pneumatic” for the pneumatic valve titles.
MBMSK_VOE_HIDE_SMART_INTEL_MODES = 0x0008, // 3 Hide smart intelligent modes
MBMSK_VOE_ENABLE_ADVANCED_CALIBRATION = 0x0010, // 4 Enable advanced calibration
MBMSK_VOE_SHOW_DOSING_PUMP_SCALING = 0x0020, // 5 Show dosing pump scaling
MBMSK_VOE_HIDE_MASTER_SLAVE_SEL = 0x0030, // 6 Hide master slave selection
MBMSK_VOE_ENABLE_ADVANCED_MASTER_SLAVE = 0x0080, // 7 Enable advanced Master Slave
MBMSK_VOE_SHOW_OVERTEMP_PROTECTION = 0x0100, // 8 Show overtemperature protection
MBMSK_VOE_SHOW_HYDRO_MODE_SEL = 0x0200, // 9 Show hidrolysis mode selection
MBMSK_VOE_SHOW_ADVANCED_EXT_CONTROL = 0x0400, // 10 Show advanced external controls
MBMSK_VOE_HIDE_BASIC_EXT_CONTROL = 0x0800, // 11 Hide basic external controls
MBMSK_VOE_HIDE_DIAGNOSTICS = 0x1000, // 12 Hide diagnostics
// MBF_PAR_UICFG_MACH_VISUAL_STYLE
MBMSK_VS_FORCE_UNITS_GRH = 0x2000, // 13 Display the hydrolysis/electrolysis in units of grams per hour (gr/h).