[Thermostat] Enhancement publishing of control method (#18235)

Enhancement publishing of control method. Independent, if hybrid mode is used or not.
This commit is contained in:
SteWers 2023-03-22 10:41:53 +01:00 committed by GitHub
parent 6aab3d4c5e
commit ab03654e02
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23

View File

@ -2028,6 +2028,9 @@ void CmndEnableOutputSet(void)
#define D_THERMOSTAT_RAMP_UP "Ramp up"
#define D_THERMOSTAT_PI "PI"
#define D_THERMOSTAT_AUTOTUNE "Autotune"
#define D_THERMOSTAT_RAMP_UP_HYBRID "Ramp up (Hybrid)"
#define D_THERMOSTAT_PI_HYBRID "PI (Hybrid)"
#define D_THERMOSTAT_AUTOTUNE_HYBRID "Autotune (Hybrid)"
// --------------------------------------------------
@ -2050,7 +2053,7 @@ void ThermostatShow(uint8_t ctr_output, bool json)
ResponseAppend_P(PSTR("%s\"%s\":%i"), "", D_CMND_THERMOSTATMODESET, Thermostat[ctr_output].status.thermostat_mode);
ResponseAppend_P(PSTR("%s\"%s\":%2_f"), ",", D_CMND_TEMPTARGETSET, &f_target_temp);
ResponseAppend_P(PSTR("%s\"%s\":%i"), ",", D_CMND_CTRDUTYCYCLEREAD, ThermostatGetDutyCycle(ctr_output));
ResponseAppend_P(PSTR("%s\"%s\":%i"), ",", D_CMND_CONTROLMETHOD, Thermostat[ctr_output].status.phase_hybrid_ctr);
ResponseAppend_P(PSTR("%s\"%s\":%i"), ",", D_CMND_CONTROLMETHOD, Thermostat[ctr_output].status.controller_mode == CTR_HYBRID ? Thermostat[ctr_output].status.phase_hybrid_ctr : Thermostat[ctr_output].status.controller_mode);
ResponseJsonEnd();
return;
}
@ -2079,19 +2082,21 @@ void ThermostatShow(uint8_t ctr_output, bool json)
}
f_temperature = value / 1000.0f;
WSContentSend_PD(HTTP_THERMOSTAT_TEMPERATURE, D_THERMOSTAT_GRADIENT, Settings->flag2.temperature_resolution, &f_temperature, c_unit);
WSContentSend_P(HTTP_THERMOSTAT_DUTY_CYCLE, ThermostatGetDutyCycle(ctr_output));
switch (Thermostat[ctr_output].status.controller_mode) {
case CTR_HYBRID:
switch (Thermostat[ctr_output].status.phase_hybrid_ctr) {
case CTR_HYBRID_RAMP_UP:
WSContentSend_P(HTTP_THERMOSTAT_CONTROL_METHOD, D_THERMOSTAT_RAMP_UP );
WSContentSend_P(HTTP_THERMOSTAT_CONTROL_METHOD, D_THERMOSTAT_RAMP_UP_HYBRID);
break;
case CTR_HYBRID_PI:
WSContentSend_P(HTTP_THERMOSTAT_CONTROL_METHOD, D_THERMOSTAT_PI );
WSContentSend_P(HTTP_THERMOSTAT_CONTROL_METHOD, D_THERMOSTAT_PI_HYBRID);
break;
#ifdef USE_PI_AUTOTUNING
case CTR_HYBRID_PI_AUTOTUNE:
WSContentSend_P(HTTP_THERMOSTAT_CONTROL_METHOD, D_THERMOSTAT_AUTOTUNE );
WSContentSend_P(HTTP_THERMOSTAT_CONTROL_METHOD, D_THERMOSTAT_AUTOTUNE_HYBRID);
break;
#endif
}
@ -2102,7 +2107,13 @@ void ThermostatShow(uint8_t ctr_output, bool json)
case CTR_RAMP_UP:
WSContentSend_P(HTTP_THERMOSTAT_CONTROL_METHOD, D_THERMOSTAT_RAMP_UP);
break;
#ifdef USE_PI_AUTOTUNING
case CTR_PI_AUTOTUNE:
WSContentSend_P(HTTP_THERMOSTAT_CONTROL_METHOD, D_THERMOSTAT_AUTOTUNE);
break;
#endif
}
WSContentSend_P(HTTP_THERMOSTAT_CYCLE_TIME, Thermostat[ctr_output].time_pi_cycle);
#ifdef USE_PI_AUTOTUNING
@ -2110,9 +2121,7 @@ void ThermostatShow(uint8_t ctr_output, bool json)
#else
WSContentSend_P(HTTP_THERMOSTAT_PI_AUTOTUNE, D_DISABLED);
#endif
}
#endif // USE_WEBSERVER
}