Updated Italian language file

5.13.1a
 * Updated Italian language file (#2618)
This commit is contained in:
Theo Arends 2018-05-04 16:31:05 +02:00
parent 7aa40cf568
commit d875dae47a
2 changed files with 28 additions and 27 deletions

View File

@ -3,6 +3,7 @@
* Fix compile error when ADC is enabled and Rules are disabled (#2608)
* Fix several timer data input and output errors (#2597, #2620)
* Add Portuguese in Brazil language file
* Updated Italian language file (#2618)
*
* 5.13.1 20180501
* Fix JSON buffers size too small for execution in some situations (#2580)

View File

@ -1,7 +1,7 @@
/*
it-IT.h - localization for Italian - Italy for Sonoff-Tasmota
Copyright (C) 2018 Gennaro Tortone
Copyright (C) 2018 Gennaro Tortone - some mods by Antonio Fragola
This program is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
@ -28,7 +28,7 @@
* Use online command StateText to translate ON, OFF, HOLD and TOGGLE.
* Use online command Prefix to translate cmnd, stat and tele.
*
* Updated until v5.12.0
* Updated until v5.13.0
\*********************************************************************/
#define LANGUAGE_MODULE_NAME // Enable to display "Module Generic" (ie Spanish), Disable to display "Generic Module" (ie English)
@ -366,34 +366,34 @@
#define D_DOMOTICZ_UPDATE_TIMER "Intervallo di aggiornamento"
// xdrv_09_timers.ino
#define D_CONFIGURE_TIMER "Configure Timer"
#define D_TIMER_PARAMETERS "Timer parameters"
#define D_TIMER_ARM "Arm"
#define D_TIMER_TIME "Time"
#define D_TIMER_DAYS "Days"
#define D_TIMER_REPEAT "Repeat"
#define D_CONFIGURE_TIMER "Configura Timer"
#define D_TIMER_PARAMETERS "Parametri Timer"
#define D_TIMER_ARM "Attiva"
#define D_TIMER_TIME "Ora"
#define D_TIMER_DAYS "Giorni"
#define D_TIMER_REPEAT "Ripeti"
#define D_TIMER_OUTPUT "Output"
#define D_TIMER_ACTION "Action"
#define D_TIMER_ACTION "Azione"
// xdrv_10_knx.ino
#define D_CONFIGURE_KNX "Configure KNX"
#define D_KNX_PARAMETERS "KNX Parameters"
#define D_KNX_GENERAL_CONFIG "General"
#define D_KNX_PHYSICAL_ADDRESS "Physical Address"
#define D_KNX_PHYSICAL_ADDRESS_NOTE "( Must be unique on the KNX network )"
#define D_KNX_ENABLE "Enable KNX"
#define D_KNX_GROUP_ADDRESS_TO_WRITE "Data to Send to Group Addresses"
#define D_ADD "Add"
#define D_DELETE "Delete"
#define D_REPLY "Reply"
#define D_KNX_GROUP_ADDRESS_TO_READ "Group Addresses to Receive Data from"
#define D_CONFIGURE_KNX "Configura KNX"
#define D_KNX_PARAMETERS "Parametri KNX"
#define D_KNX_GENERAL_CONFIG "Generale"
#define D_KNX_PHYSICAL_ADDRESS "Indirizzo Fisico"
#define D_KNX_PHYSICAL_ADDRESS_NOTE "( Deve essere univoco nella rete KNX )"
#define D_KNX_ENABLE "Abilita KNX"
#define D_KNX_GROUP_ADDRESS_TO_WRITE "Dati da Inviare al Gruppo di Indirizzi"
#define D_ADD "Aggiungi"
#define D_DELETE "Elimina"
#define D_REPLY "Rispondi"
#define D_KNX_GROUP_ADDRESS_TO_READ "Gruppo di Indirizzi da cui Ricevere Dati"
#define D_LOG_KNX "KNX: "
#define D_RECEIVED_FROM "Received from"
#define D_KNX_COMMAND_WRITE "Write"
#define D_KNX_COMMAND_READ "Read"
#define D_KNX_COMMAND_OTHER "Other"
#define D_SENT_TO "sent to"
#define D_KNX_WARNING "The group address ( 0 / 0 / 0 ) is reserved and can not be used."
#define D_RECEIVED_FROM "Ricevuto Da"
#define D_KNX_COMMAND_WRITE "Scrivi"
#define D_KNX_COMMAND_READ "Leggi"
#define D_KNX_COMMAND_OTHER "Altro"
#define D_SENT_TO "invia a"
#define D_KNX_WARNING "L'indirizzo del gruppo ( 0 / 0 / 0 ) è riservato e non può essere usato."
// xdrv_03_energy.ino
#define D_ENERGY_TODAY "Energia Oggi"
@ -422,7 +422,7 @@
#define D_PARTICALS_BEYOND "Particelle"
// sonoff_template.h
#define D_SENSOR_NONE "None"
#define D_SENSOR_NONE "Nessuno"
#define D_SENSOR_DHT11 "DHT11"
#define D_SENSOR_AM2301 "AM2301"
#define D_SENSOR_SI7021 "SI7021"