# Usermod BME68X
|
||||
|
||||
This usermod was developed for a BME680/BME68X sensor. The BME68X is not compatible with the BME280/BMP280 chip. It has its own library. The original 'BSEC Software Library' from Bosch was used to develop the code. The measured values are displayed on the WLED info page.
|
||||
|
||||
<p align="center"><img src="pics/pic1.png" style="width:60%;"></p>
|
||||
|
||||
In addition, the values are published on MQTT if this is active. The topic used for this is: 'wled/[MQTT Client ID]'. The Client ID is set in the WLED MQTT settings.
|
||||
|
||||
<p align="center"><img src="pics/pic2.png"></p>
|
||||
|
||||
If you use HomeAssistance discovery, the device tree for HomeAssistance is created. This is published under the topic 'homeassistant/sensor/[MQTT Client ID]' via MQTT.
|
||||
|
||||
<p align="center"><img src="pics/pic3.png"></p>
|
||||
|
||||
A device with the following sensors appears in HomeAssistant. Please note that MQTT must be activated in HomeAssistant.
|
||||
|
||||
<p align="center"><img src="pics/pic4.png" style="width:60%;"></p>
|
||||
|
||||
|
||||
## Features
|
||||
|
||||
Raw sensor types
|
||||
|
||||
Sensor Accuracy Scale Range
|
||||
--------------------------------------------------------------------------------------------------
|
||||
Temperature +/- 1.0 °C/°F -40 to 85 °C
|
||||
Humidity +/- 3 % 0 to 100 %
|
||||
Pressure +/- 1 hPa 300 to 1100 hPa
|
||||
Gas Resistance Ohm
|
||||
Sensor Accuracy Scale Range
|
||||
-----------------------------
|
||||
|
||||
Temperature +/- 1.0 °C/°F -40 to 85 °C
|
||||
Humidity +/- 3 % 0 to 100 %
|
||||
Pressure +/- 1 hPa 300 to 1100 hPa
|
||||
Gas Resistance Ohm
|
||||
The BSEC Library calculates the following values via the gas resistance
|
||||
|
||||
Sensor Accuracy Scale Range
|
||||
--------------------------------------------------------------------------------------------------
|
||||
IAQ value between 0 and 500
|
||||
Static IAQ same as IAQ but for permanently installed devices
|
||||
CO2 PPM
|
||||
VOC PPM
|
||||
Gas-Percentage %
|
||||
|
||||
Sensor Accuracy Scale Range
|
||||
-----------------------------
|
||||
|
||||
IAQ value between 0 and 500
|
||||
Static IAQ same as IAQ but for permanently installed devices
|
||||
CO2 PPM
|
||||
VOC PPM
|
||||
Gas-Percentage %
|
||||
In addition the usermod calculates
|
||||
|
||||
Sensor Accuracy Scale Range
|
||||
--------------------------------------------------------------------------------------------------
|
||||
Absolute humidity g/m³
|
||||
Dew point °C/°F
|
||||
Sensor Accuracy Scale Range
|
||||
-----------------------------
|
||||
|
||||
Absolute humidity g/m³
|
||||
Dew point °C/°F
|
||||
|
||||
### IAQ (Indoor Air Quality)
|
||||
|
||||
The IAQ is divided into the following value groups.
|
||||
|
||||
<p align="center"><img src="pics/pic5.png"></p>
|
||||
|
||||
For more detailed information, please consult the enclosed Bosch product description (BME680.pdf).
|
||||
|
||||
|
||||
## Calibration of the device
|
||||
|
||||
The gas sensor of the BME68X must be calibrated. This differs from the BME280, which does not require any calibration.
|
||||
@ -67,10 +72,10 @@ The IAQ index is therefore only meaningful if IAQ Accuracy = 3. In addition to t
|
||||
|
||||
Reasonably reliable values are therefore only achieved when accuracy displays the value 3.
|
||||
|
||||
|
||||
|
||||
## Settings
|
||||
|
||||
The settings of the usermods are set in the usermod section of wled.
|
||||
|
||||
<p align="center"><img src="pics/pic6.png"></p>
|
||||
|
||||
The possible settings are
|
||||
@ -88,6 +93,7 @@ The possible settings are
|
||||
- **Del Calibration Hist:** If a check mark is set here, the calibration file saved in the file system is deleted when the settings are saved.
|
||||
|
||||
### Sensors
|
||||
|
||||
Applies to all sensors. The number of decimal places is set here. If the sensor is set to -1, it will no longer be published. In addition, the IAQ values can be activated here in verbal form.
|
||||
|
||||
It is recommended to use the Static IAQ for the IAQ values. This is recommended by Bosch for statically placed devices.
|
||||
@ -99,6 +105,7 @@ Data is published over MQTT - make sure you've enabled the MQTT sync interface.
|
||||
In addition to outputting via MQTT, you can read the values from the Info Screen on the dashboard page of the device's web interface.
|
||||
|
||||
Methods also exist to read the read/calculated values from other WLED modules through code.
|
||||
|
||||
- getTemperature(); The scale °C/°F is depended to the settings
|
||||
- getHumidity();
|
||||
- getPressure();
|
||||
@ -118,15 +125,36 @@ Methods also exist to read the read/calculated values from other WLED modules th
|
||||
- getStabStatus();
|
||||
- getRunInStatus();
|
||||
|
||||
## Compilation
|
||||
|
||||
To enable, compile with `BME68X` in `custom_usermods` (e.g. in `platformio_override.ini`)
|
||||
|
||||
Example:
|
||||
|
||||
```[env:esp32_mySpecial]
|
||||
extends = env:esp32dev
|
||||
custom_usermods = ${env:esp32dev.custom_usermods} BME68X
|
||||
```
|
||||
|
||||
## Revision History
|
||||
|
||||
### Version 1.0.0
|
||||
|
||||
- First version of the BME68X_v user module
|
||||
|
||||
### Version 1.0.1
|
||||
|
||||
- Rebased to WELD Version 0.15
|
||||
- Reworked some default settings
|
||||
- A problem with the default settings has been fixed
|
||||
|
||||
### Version 1.0.2
|
||||
|
||||
* Rebased to WELD Version 0.16
|
||||
* Fixed: Solved compilation problems related to some macro naming interferences.
|
||||
|
||||
## Known problems
|
||||
|
||||
- MQTT goes online at device start. Shortly afterwards it goes offline and takes quite a while until it goes online again. The problem does not come from this user module, but from the WLED core.
|
||||
- If you save the settings often, WLED can get stuck.
|
||||
- If many LEDS are connected to WLED, reading the sensor can cause a small but noticeable hang. The "Pause While WLED Active" option was introduced as a workaround.
|
||||
|