Merge pull request #3966 from LordMike/feature/bme280_changeable_i2c

Add changeable i2c address to BME280 usermod
This commit is contained in:
Blaž Kristan 2024-05-14 19:39:42 +02:00 committed by GitHub
commit 5f41de8938
No known key found for this signature in database
GPG Key ID: B5690EEEBB952194
2 changed files with 65 additions and 39 deletions

View File

@ -7,6 +7,7 @@ This Usermod is designed to read a `BME280` or `BMP280` sensor and output the fo
- Dew Point (`BME280` only)
Configuration is performed via the Usermod menu. There are no parameters to set in code! The following settings can be configured in the Usermod Menu:
- The i2c address in decimal. Set it to either 118 (0x76, the default) or 119 (0x77).
- Temperature Decimals (number of decimal places to output)
- Humidity Decimals
- Pressure Decimals

View File

@ -24,6 +24,7 @@ private:
uint8_t PressureDecimals = 0; // Number of decimal places in published pressure values
uint16_t TemperatureInterval = 5; // Interval to measure temperature (and humidity, dew point if available) in seconds
uint16_t PressureInterval = 300; // Interval to measure pressure in seconds
BME280I2C::I2CAddr I2CAddress = BME280I2C::I2CAddr_0x76; // i2c address, defaults to 0x76
bool PublishAlways = false; // Publish values even when they have not changed
bool UseCelsius = true; // Use Celsius for Reporting
bool HomeAssistantDiscovery = false; // Publish Home Assistant Device Information
@ -35,20 +36,7 @@ private:
#endif
bool initDone = false;
// BME280 sensor settings
BME280I2C::Settings settings{
BME280::OSR_X16, // Temperature oversampling x16
BME280::OSR_X16, // Humidity oversampling x16
BME280::OSR_X16, // Pressure oversampling x16
// Defaults
BME280::Mode_Forced,
BME280::StandbyTime_1000ms,
BME280::Filter_Off,
BME280::SpiEnable_False,
BME280I2C::I2CAddr_0x76 // I2C address. I2C specific. Default 0x76
};
BME280I2C bme{settings};
BME280I2C bme;
uint8_t sensorType;
@ -181,34 +169,52 @@ private:
}
}
void initializeBmeComms()
{
BME280I2C::Settings settings{
BME280::OSR_X16, // Temperature oversampling x16
BME280::OSR_X16, // Humidity oversampling x16
BME280::OSR_X16, // Pressure oversampling x16
BME280::Mode_Forced,
BME280::StandbyTime_1000ms,
BME280::Filter_Off,
BME280::SpiEnable_False,
I2CAddress
};
bme.setSettings(settings);
if (!bme.begin())
{
sensorType = 0;
DEBUG_PRINTLN(F("Could not find BME280 I2C sensor!"));
}
else
{
switch (bme.chipModel())
{
case BME280::ChipModel_BME280:
sensorType = 1;
DEBUG_PRINTLN(F("Found BME280 sensor! Success."));
break;
case BME280::ChipModel_BMP280:
sensorType = 2;
DEBUG_PRINTLN(F("Found BMP280 sensor! No Humidity available."));
break;
default:
sensorType = 0;
DEBUG_PRINTLN(F("Found UNKNOWN sensor! Error!"));
}
}
}
public:
void setup()
{
if (i2c_scl<0 || i2c_sda<0) { enabled = false; sensorType = 0; return; }
if (!bme.begin())
{
sensorType = 0;
DEBUG_PRINTLN(F("Could not find BME280 I2C sensor!"));
}
else
{
switch (bme.chipModel())
{
case BME280::ChipModel_BME280:
sensorType = 1;
DEBUG_PRINTLN(F("Found BME280 sensor! Success."));
break;
case BME280::ChipModel_BMP280:
sensorType = 2;
DEBUG_PRINTLN(F("Found BMP280 sensor! No Humidity available."));
break;
default:
sensorType = 0;
DEBUG_PRINTLN(F("Found UNKNOWN sensor! Error!"));
}
}
initDone=true;
initializeBmeComms();
initDone = true;
}
void loop()
@ -365,7 +371,6 @@ public:
}
else if (sensorType==2) //BMP280
{
JsonArray temperature_json = user.createNestedArray(F("Temperature"));
JsonArray pressure_json = user.createNestedArray(F("Pressure"));
temperature_json.add(roundf(sensorTemperature * powf(10, TemperatureDecimals)) / powf(10, TemperatureDecimals));
@ -399,6 +404,7 @@ public:
{
JsonObject top = root.createNestedObject(FPSTR(_name));
top[FPSTR(_enabled)] = enabled;
top[F("I2CAddress")] = static_cast<uint8_t>(I2CAddress);
top[F("TemperatureDecimals")] = TemperatureDecimals;
top[F("HumidityDecimals")] = HumidityDecimals;
top[F("PressureDecimals")] = PressureDecimals;
@ -426,6 +432,10 @@ public:
configComplete &= getJsonValue(top[FPSTR(_enabled)], enabled);
// A 3-argument getJsonValue() assigns the 3rd argument as a default value if the Json value is missing
uint8_t tmpI2cAddress;
configComplete &= getJsonValue(top[F("I2CAddress")], tmpI2cAddress, 0x76);
I2CAddress = static_cast<BME280I2C::I2CAddr>(tmpI2cAddress);
configComplete &= getJsonValue(top[F("TemperatureDecimals")], TemperatureDecimals, 1);
configComplete &= getJsonValue(top[F("HumidityDecimals")], HumidityDecimals, 0);
configComplete &= getJsonValue(top[F("PressureDecimals")], PressureDecimals, 0);
@ -440,8 +450,23 @@ public:
// first run: reading from cfg.json
DEBUG_PRINTLN(F(" config loaded."));
} else {
DEBUG_PRINTLN(F(" config (re)loaded."));
// changing parameters from settings page
DEBUG_PRINTLN(F(" config (re)loaded."));
// Reset all known values
sensorType = 0;
sensorTemperature = 0;
sensorHumidity = 0;
sensorHeatIndex = 0;
sensorDewPoint = 0;
sensorPressure = 0;
lastTemperature = 0;
lastHumidity = 0;
lastHeatIndex = 0;
lastDewPoint = 0;
lastPressure = 0;
initializeBmeComms();
}
return configComplete;