settings_leds: Initialize current limiter field

When adding a new bus, the numeric current limit field was not being
initialized; this was causing it to save 0 when saved instead of the
default 55mA value.
This commit is contained in:
Will Miles 2024-12-01 13:00:37 -05:00
parent a121f5b61b
commit 8b1d712e1e

View File

@ -422,7 +422,7 @@ mA/LED: <select name="LAsel${s}" onchange="enLA(this,'${s}');UI();">
<option value="15">15mA (seed/fairy pixels)</option>
<option value="0">Custom</option>
</select><br>
<div id="LAdis${s}" style="display: none;">max. mA/LED: <input name="LA${s}" type="number" min="1" max="255" oninput="UI()"> mA<br></div>
<div id="LAdis${s}" style="display: none;">max. mA/LED: <input name="LA${s}" type="number" min="1" max="255" oninput="UI()" value=55> mA<br></div>
<div id="PSU${s}">PSU: <input name="MA${s}" type="number" class="xl" min="250" max="65000" oninput="UI()" value="250"> mA<br></div>