mirror of
https://github.com/home-assistant/core.git
synced 2025-07-21 12:17:07 +00:00
Add additional test coverage for zwave_js meter sensors (#55465)
This commit is contained in:
parent
7dbd0e5274
commit
02eba22068
@ -201,7 +201,7 @@ class NumericSensorDataTemplate(BaseDiscoverySchemaDataTemplate):
|
|||||||
):
|
):
|
||||||
return ENTITY_DESC_KEY_TOTAL_INCREASING
|
return ENTITY_DESC_KEY_TOTAL_INCREASING
|
||||||
# We do this because even though these are power scales, they don't meet
|
# We do this because even though these are power scales, they don't meet
|
||||||
# the unit requirements for the energy power class.
|
# the unit requirements for the power device class.
|
||||||
if scale_type == ElectricScale.KILOVOLT_AMPERE_REACTIVE:
|
if scale_type == ElectricScale.KILOVOLT_AMPERE_REACTIVE:
|
||||||
return ENTITY_DESC_KEY_MEASUREMENT
|
return ENTITY_DESC_KEY_MEASUREMENT
|
||||||
|
|
||||||
|
@ -1,17 +1,24 @@
|
|||||||
"""Test the Z-Wave JS sensor platform."""
|
"""Test the Z-Wave JS sensor platform."""
|
||||||
|
import copy
|
||||||
|
|
||||||
|
from zwave_js_server.const.command_class.meter import MeterType
|
||||||
from zwave_js_server.event import Event
|
from zwave_js_server.event import Event
|
||||||
|
from zwave_js_server.model.node import Node
|
||||||
|
|
||||||
from homeassistant.components.sensor import (
|
from homeassistant.components.sensor import (
|
||||||
|
ATTR_STATE_CLASS,
|
||||||
STATE_CLASS_MEASUREMENT,
|
STATE_CLASS_MEASUREMENT,
|
||||||
STATE_CLASS_TOTAL_INCREASING,
|
STATE_CLASS_TOTAL_INCREASING,
|
||||||
)
|
)
|
||||||
from homeassistant.components.zwave_js.const import (
|
from homeassistant.components.zwave_js.const import (
|
||||||
ATTR_METER_TYPE,
|
ATTR_METER_TYPE,
|
||||||
|
ATTR_METER_TYPE_NAME,
|
||||||
ATTR_VALUE,
|
ATTR_VALUE,
|
||||||
DOMAIN,
|
DOMAIN,
|
||||||
SERVICE_RESET_METER,
|
SERVICE_RESET_METER,
|
||||||
)
|
)
|
||||||
from homeassistant.const import (
|
from homeassistant.const import (
|
||||||
|
ATTR_DEVICE_CLASS,
|
||||||
ATTR_ENTITY_ID,
|
ATTR_ENTITY_ID,
|
||||||
DEVICE_CLASS_CURRENT,
|
DEVICE_CLASS_CURRENT,
|
||||||
DEVICE_CLASS_ENERGY,
|
DEVICE_CLASS_ENERGY,
|
||||||
@ -268,3 +275,85 @@ async def test_reset_meter(
|
|||||||
assert args["args"] == [{"type": 1, "targetValue": 2}]
|
assert args["args"] == [{"type": 1, "targetValue": 2}]
|
||||||
|
|
||||||
client.async_send_command_no_wait.reset_mock()
|
client.async_send_command_no_wait.reset_mock()
|
||||||
|
|
||||||
|
|
||||||
|
async def test_meter_attributes(
|
||||||
|
hass,
|
||||||
|
client,
|
||||||
|
aeon_smart_switch_6,
|
||||||
|
integration,
|
||||||
|
):
|
||||||
|
"""Test meter entity attributes."""
|
||||||
|
state = hass.states.get(METER_ENERGY_SENSOR)
|
||||||
|
assert state
|
||||||
|
assert state.attributes[ATTR_METER_TYPE] == MeterType.ELECTRIC.value
|
||||||
|
assert state.attributes[ATTR_METER_TYPE_NAME] == MeterType.ELECTRIC.name
|
||||||
|
assert state.attributes[ATTR_DEVICE_CLASS] == DEVICE_CLASS_ENERGY
|
||||||
|
assert state.attributes[ATTR_STATE_CLASS] == STATE_CLASS_TOTAL_INCREASING
|
||||||
|
|
||||||
|
|
||||||
|
async def test_special_meters(hass, aeon_smart_switch_6_state, client, integration):
|
||||||
|
"""Test meters that have special handling."""
|
||||||
|
node_data = copy.deepcopy(
|
||||||
|
aeon_smart_switch_6_state
|
||||||
|
) # Copy to allow modification in tests.
|
||||||
|
# Add an ElectricScale.KILOVOLT_AMPERE_HOUR value to the state so we can test that
|
||||||
|
# it is handled differently (no device class)
|
||||||
|
node_data["values"].append(
|
||||||
|
{
|
||||||
|
"endpoint": 10,
|
||||||
|
"commandClass": 50,
|
||||||
|
"commandClassName": "Meter",
|
||||||
|
"property": "value",
|
||||||
|
"propertyKey": 65537,
|
||||||
|
"propertyName": "value",
|
||||||
|
"propertyKeyName": "Electric_kVah_Consumed",
|
||||||
|
"ccVersion": 3,
|
||||||
|
"metadata": {
|
||||||
|
"type": "number",
|
||||||
|
"readable": True,
|
||||||
|
"writeable": False,
|
||||||
|
"label": "Electric Consumed [kVah]",
|
||||||
|
"unit": "kVah",
|
||||||
|
"ccSpecific": {"meterType": 1, "rateType": 1, "scale": 1},
|
||||||
|
},
|
||||||
|
"value": 659.813,
|
||||||
|
},
|
||||||
|
)
|
||||||
|
# Add an ElectricScale.KILOVOLT_AMPERE_REACTIVE value to the state so we can test that
|
||||||
|
# it is handled differently (no device class)
|
||||||
|
node_data["values"].append(
|
||||||
|
{
|
||||||
|
"endpoint": 11,
|
||||||
|
"commandClass": 50,
|
||||||
|
"commandClassName": "Meter",
|
||||||
|
"property": "value",
|
||||||
|
"propertyKey": 65537,
|
||||||
|
"propertyName": "value",
|
||||||
|
"propertyKeyName": "Electric_kVa_reactive_Consumed",
|
||||||
|
"ccVersion": 3,
|
||||||
|
"metadata": {
|
||||||
|
"type": "number",
|
||||||
|
"readable": True,
|
||||||
|
"writeable": False,
|
||||||
|
"label": "Electric Consumed [kVa reactive]",
|
||||||
|
"unit": "kVa reactive",
|
||||||
|
"ccSpecific": {"meterType": 1, "rateType": 1, "scale": 7},
|
||||||
|
},
|
||||||
|
"value": 659.813,
|
||||||
|
},
|
||||||
|
)
|
||||||
|
node = Node(client, node_data)
|
||||||
|
event = {"node": node}
|
||||||
|
client.driver.controller.emit("node added", event)
|
||||||
|
await hass.async_block_till_done()
|
||||||
|
|
||||||
|
state = hass.states.get("sensor.smart_switch_6_electric_consumed_kvah_10")
|
||||||
|
assert state
|
||||||
|
assert ATTR_DEVICE_CLASS not in state.attributes
|
||||||
|
assert state.attributes[ATTR_STATE_CLASS] == STATE_CLASS_TOTAL_INCREASING
|
||||||
|
|
||||||
|
state = hass.states.get("sensor.smart_switch_6_electric_consumed_kva_reactive_11")
|
||||||
|
assert state
|
||||||
|
assert ATTR_DEVICE_CLASS not in state.attributes
|
||||||
|
assert state.attributes[ATTR_STATE_CLASS] == STATE_CLASS_MEASUREMENT
|
||||||
|
Loading…