mirror of
https://github.com/home-assistant/core.git
synced 2025-07-15 17:27:10 +00:00
Add opentherm_gw binary sensor support (#17625)
* Add OpenTherm Gateway binary sensor support. * opentherm_gw binary_sensor platform does not need polling.
This commit is contained in:
parent
2e973c7572
commit
237ac08076
145
homeassistant/components/binary_sensor/opentherm_gw.py
Normal file
145
homeassistant/components/binary_sensor/opentherm_gw.py
Normal file
@ -0,0 +1,145 @@
|
||||
"""
|
||||
Support for OpenTherm Gateway binary sensors.
|
||||
|
||||
For more details about this platform, please refer to the documentation at
|
||||
http://home-assistant.io/components/binary_sensor.opentherm_gw/
|
||||
"""
|
||||
import logging
|
||||
|
||||
from homeassistant.components.binary_sensor import (
|
||||
BinarySensorDevice, ENTITY_ID_FORMAT)
|
||||
from homeassistant.components.opentherm_gw import (
|
||||
DATA_GW_VARS, DATA_OPENTHERM_GW, SIGNAL_OPENTHERM_GW_UPDATE)
|
||||
from homeassistant.helpers.dispatcher import async_dispatcher_connect
|
||||
from homeassistant.helpers.entity import async_generate_entity_id
|
||||
|
||||
DEVICE_CLASS_COLD = 'cold'
|
||||
DEVICE_CLASS_HEAT = 'heat'
|
||||
DEVICE_CLASS_PROBLEM = 'problem'
|
||||
|
||||
DEPENDENCIES = ['opentherm_gw']
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
||||
|
||||
async def async_setup_platform(hass, config, async_add_entities,
|
||||
discovery_info=None):
|
||||
"""Set up the OpenTherm Gateway binary sensors."""
|
||||
if discovery_info is None:
|
||||
return
|
||||
gw_vars = hass.data[DATA_OPENTHERM_GW][DATA_GW_VARS]
|
||||
sensor_info = {
|
||||
# [device_class, friendly_name]
|
||||
gw_vars.DATA_MASTER_CH_ENABLED: [
|
||||
None, "Thermostat Central Heating Enabled"],
|
||||
gw_vars.DATA_MASTER_DHW_ENABLED: [
|
||||
None, "Thermostat Hot Water Enabled"],
|
||||
gw_vars.DATA_MASTER_COOLING_ENABLED: [
|
||||
None, "Thermostat Cooling Enabled"],
|
||||
gw_vars.DATA_MASTER_OTC_ENABLED: [
|
||||
None, "Thermostat Outside Temperature Correction Enabled"],
|
||||
gw_vars.DATA_MASTER_CH2_ENABLED: [
|
||||
None, "Thermostat Central Heating 2 Enabled"],
|
||||
gw_vars.DATA_SLAVE_FAULT_IND: [
|
||||
DEVICE_CLASS_PROBLEM, "Boiler Fault Indication"],
|
||||
gw_vars.DATA_SLAVE_CH_ACTIVE: [
|
||||
DEVICE_CLASS_HEAT, "Boiler Central Heating Status"],
|
||||
gw_vars.DATA_SLAVE_DHW_ACTIVE: [
|
||||
DEVICE_CLASS_HEAT, "Boiler Hot Water Status"],
|
||||
gw_vars.DATA_SLAVE_FLAME_ON: [
|
||||
DEVICE_CLASS_HEAT, "Boiler Flame Status"],
|
||||
gw_vars.DATA_SLAVE_COOLING_ACTIVE: [
|
||||
DEVICE_CLASS_COLD, "Boiler Cooling Status"],
|
||||
gw_vars.DATA_SLAVE_CH2_ACTIVE: [
|
||||
DEVICE_CLASS_HEAT, "Boiler Central Heating 2 Status"],
|
||||
gw_vars.DATA_SLAVE_DIAG_IND: [
|
||||
DEVICE_CLASS_PROBLEM, "Boiler Diagnostics Indication"],
|
||||
gw_vars.DATA_SLAVE_DHW_PRESENT: [None, "Boiler Hot Water Present"],
|
||||
gw_vars.DATA_SLAVE_CONTROL_TYPE: [None, "Boiler Control Type"],
|
||||
gw_vars.DATA_SLAVE_COOLING_SUPPORTED: [None, "Boiler Cooling Support"],
|
||||
gw_vars.DATA_SLAVE_DHW_CONFIG: [
|
||||
None, "Boiler Hot Water Configuration"],
|
||||
gw_vars.DATA_SLAVE_MASTER_LOW_OFF_PUMP: [
|
||||
None, "Boiler Pump Commands Support"],
|
||||
gw_vars.DATA_SLAVE_CH2_PRESENT: [
|
||||
None, "Boiler Central Heating 2 Present"],
|
||||
gw_vars.DATA_SLAVE_SERVICE_REQ: [
|
||||
DEVICE_CLASS_PROBLEM, "Boiler Service Required"],
|
||||
gw_vars.DATA_SLAVE_REMOTE_RESET: [None, "Boiler Remote Reset Support"],
|
||||
gw_vars.DATA_SLAVE_LOW_WATER_PRESS: [
|
||||
DEVICE_CLASS_PROBLEM, "Boiler Low Water Pressure"],
|
||||
gw_vars.DATA_SLAVE_GAS_FAULT: [
|
||||
DEVICE_CLASS_PROBLEM, "Boiler Gas Fault"],
|
||||
gw_vars.DATA_SLAVE_AIR_PRESS_FAULT: [
|
||||
DEVICE_CLASS_PROBLEM, "Boiler Air Pressure Fault"],
|
||||
gw_vars.DATA_SLAVE_WATER_OVERTEMP: [
|
||||
DEVICE_CLASS_PROBLEM, "Boiler Water Overtemperature"],
|
||||
gw_vars.DATA_REMOTE_TRANSFER_DHW: [
|
||||
None, "Remote Hot Water Setpoint Transfer Support"],
|
||||
gw_vars.DATA_REMOTE_TRANSFER_MAX_CH: [
|
||||
None, "Remote Maximum Central Heating Setpoint Write Support"],
|
||||
gw_vars.DATA_REMOTE_RW_DHW: [
|
||||
None, "Remote Hot Water Setpoint Write Support"],
|
||||
gw_vars.DATA_REMOTE_RW_MAX_CH: [
|
||||
None, "Remote Central Heating Setpoint Write Support"],
|
||||
gw_vars.DATA_ROVRD_MAN_PRIO: [
|
||||
None, "Remote Override Manual Change Priority"],
|
||||
gw_vars.DATA_ROVRD_AUTO_PRIO: [
|
||||
None, "Remote Override Program Change Priority"],
|
||||
gw_vars.OTGW_GPIO_A_STATE: [None, "Gateway GPIO A State"],
|
||||
gw_vars.OTGW_GPIO_B_STATE: [None, "Gateway GPIO B State"],
|
||||
gw_vars.OTGW_IGNORE_TRANSITIONS: [None, "Gateway Ignore Transitions"],
|
||||
gw_vars.OTGW_OVRD_HB: [None, "Gateway Override High Byte"],
|
||||
}
|
||||
sensors = []
|
||||
for var in discovery_info:
|
||||
device_class = sensor_info[var][0]
|
||||
friendly_name = sensor_info[var][1]
|
||||
entity_id = async_generate_entity_id(ENTITY_ID_FORMAT, var, hass=hass)
|
||||
sensors.append(OpenThermBinarySensor(entity_id, var, device_class,
|
||||
friendly_name))
|
||||
async_add_entities(sensors)
|
||||
|
||||
|
||||
class OpenThermBinarySensor(BinarySensorDevice):
|
||||
"""Represent an OpenTherm Gateway binary sensor."""
|
||||
|
||||
def __init__(self, entity_id, var, device_class, friendly_name):
|
||||
"""Initialize the binary sensor."""
|
||||
self.entity_id = entity_id
|
||||
self._var = var
|
||||
self._state = None
|
||||
self._device_class = device_class
|
||||
self._friendly_name = friendly_name
|
||||
|
||||
async def async_added_to_hass(self):
|
||||
"""Subscribe to updates from the component."""
|
||||
_LOGGER.debug(
|
||||
"Added OpenTherm Gateway binary sensor %s", self._friendly_name)
|
||||
async_dispatcher_connect(self.hass, SIGNAL_OPENTHERM_GW_UPDATE,
|
||||
self.receive_report)
|
||||
|
||||
async def receive_report(self, status):
|
||||
"""Handle status updates from the component."""
|
||||
self._state = bool(status.get(self._var))
|
||||
self.async_schedule_update_ha_state()
|
||||
|
||||
@property
|
||||
def name(self):
|
||||
"""Return the friendly name."""
|
||||
return self._friendly_name
|
||||
|
||||
@property
|
||||
def is_on(self):
|
||||
"""Return true if the binary sensor is on."""
|
||||
return self._state
|
||||
|
||||
@property
|
||||
def device_class(self):
|
||||
"""Return the class of this device."""
|
||||
return self._device_class
|
||||
|
||||
@property
|
||||
def should_poll(self):
|
||||
"""Return False because entity pushes its state."""
|
||||
return False
|
@ -8,6 +8,7 @@ import logging
|
||||
|
||||
import voluptuous as vol
|
||||
|
||||
from homeassistant.components.binary_sensor import DOMAIN as COMP_BINARY_SENSOR
|
||||
from homeassistant.components.sensor import DOMAIN as COMP_SENSOR
|
||||
from homeassistant.const import (CONF_DEVICE, CONF_MONITORED_VARIABLES,
|
||||
CONF_NAME, PRECISION_HALVES, PRECISION_TENTHS,
|
||||
@ -55,6 +56,7 @@ async def async_setup(hass, config):
|
||||
import pyotgw
|
||||
conf = config[DOMAIN]
|
||||
gateway = pyotgw.pyotgw()
|
||||
monitored_vars = conf.get(CONF_MONITORED_VARIABLES)
|
||||
hass.data[DATA_OPENTHERM_GW] = {
|
||||
DATA_DEVICE: gateway,
|
||||
DATA_GW_VARS: pyotgw.vars,
|
||||
@ -63,8 +65,8 @@ async def async_setup(hass, config):
|
||||
hass, conf[CONF_DEVICE], gateway))
|
||||
hass.async_create_task(async_load_platform(
|
||||
hass, 'climate', DOMAIN, conf.get(CONF_CLIMATE)))
|
||||
hass.async_create_task(setup_monitored_vars(
|
||||
hass, conf.get(CONF_MONITORED_VARIABLES)))
|
||||
if monitored_vars:
|
||||
hass.async_create_task(setup_monitored_vars(hass, monitored_vars))
|
||||
return True
|
||||
|
||||
|
||||
@ -83,8 +85,43 @@ async def connect_and_subscribe(hass, device_path, gateway):
|
||||
async def setup_monitored_vars(hass, monitored_vars):
|
||||
"""Set up requested sensors."""
|
||||
gw_vars = hass.data[DATA_OPENTHERM_GW][DATA_GW_VARS]
|
||||
# Use dict to prepare for binary sensor support.
|
||||
sensor_type_map = {
|
||||
COMP_BINARY_SENSOR: [
|
||||
gw_vars.DATA_MASTER_CH_ENABLED,
|
||||
gw_vars.DATA_MASTER_DHW_ENABLED,
|
||||
gw_vars.DATA_MASTER_COOLING_ENABLED,
|
||||
gw_vars.DATA_MASTER_OTC_ENABLED,
|
||||
gw_vars.DATA_MASTER_CH2_ENABLED,
|
||||
gw_vars.DATA_SLAVE_FAULT_IND,
|
||||
gw_vars.DATA_SLAVE_CH_ACTIVE,
|
||||
gw_vars.DATA_SLAVE_DHW_ACTIVE,
|
||||
gw_vars.DATA_SLAVE_FLAME_ON,
|
||||
gw_vars.DATA_SLAVE_COOLING_ACTIVE,
|
||||
gw_vars.DATA_SLAVE_CH2_ACTIVE,
|
||||
gw_vars.DATA_SLAVE_DIAG_IND,
|
||||
gw_vars.DATA_SLAVE_DHW_PRESENT,
|
||||
gw_vars.DATA_SLAVE_CONTROL_TYPE,
|
||||
gw_vars.DATA_SLAVE_COOLING_SUPPORTED,
|
||||
gw_vars.DATA_SLAVE_DHW_CONFIG,
|
||||
gw_vars.DATA_SLAVE_MASTER_LOW_OFF_PUMP,
|
||||
gw_vars.DATA_SLAVE_CH2_PRESENT,
|
||||
gw_vars.DATA_SLAVE_SERVICE_REQ,
|
||||
gw_vars.DATA_SLAVE_REMOTE_RESET,
|
||||
gw_vars.DATA_SLAVE_LOW_WATER_PRESS,
|
||||
gw_vars.DATA_SLAVE_GAS_FAULT,
|
||||
gw_vars.DATA_SLAVE_AIR_PRESS_FAULT,
|
||||
gw_vars.DATA_SLAVE_WATER_OVERTEMP,
|
||||
gw_vars.DATA_REMOTE_TRANSFER_DHW,
|
||||
gw_vars.DATA_REMOTE_TRANSFER_MAX_CH,
|
||||
gw_vars.DATA_REMOTE_RW_DHW,
|
||||
gw_vars.DATA_REMOTE_RW_MAX_CH,
|
||||
gw_vars.DATA_ROVRD_MAN_PRIO,
|
||||
gw_vars.DATA_ROVRD_AUTO_PRIO,
|
||||
gw_vars.OTGW_GPIO_A_STATE,
|
||||
gw_vars.OTGW_GPIO_B_STATE,
|
||||
gw_vars.OTGW_IGNORE_TRANSITIONS,
|
||||
gw_vars.OTGW_OVRD_HB,
|
||||
],
|
||||
COMP_SENSOR: [
|
||||
gw_vars.DATA_CONTROL_SETPOINT,
|
||||
gw_vars.DATA_MASTER_MEMBERID,
|
||||
@ -152,11 +189,17 @@ async def setup_monitored_vars(hass, monitored_vars):
|
||||
gw_vars.OTGW_VREF,
|
||||
]
|
||||
}
|
||||
binary_sensors = []
|
||||
sensors = []
|
||||
for var in monitored_vars:
|
||||
if var in sensor_type_map[COMP_SENSOR]:
|
||||
sensors.append(var)
|
||||
elif var in sensor_type_map[COMP_BINARY_SENSOR]:
|
||||
binary_sensors.append(var)
|
||||
else:
|
||||
_LOGGER.error("Monitored variable not supported: %s", var)
|
||||
if binary_sensors:
|
||||
hass.async_create_task(async_load_platform(
|
||||
hass, COMP_BINARY_SENSOR, DOMAIN, binary_sensors))
|
||||
if sensors:
|
||||
await async_load_platform(hass, COMP_SENSOR, DOMAIN, sensors)
|
||||
|
Loading…
x
Reference in New Issue