@ -3,59 +3,8 @@ homeassistant.components.thermostat.heat_control
|
|||||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
Adds support for a thermostat.
|
Adds support for a thermostat.
|
||||||
|
|
||||||
Specify a start time, end time and a target temperature.
|
For more details about this platform, please refer to the documentation at
|
||||||
If the the current temperature is lower than the target temperature,
|
https://home-assistant.io/components/thermostat.heat_control.html
|
||||||
and the time is between start time and end time, the heater will
|
|
||||||
be turned on. Opposite if the the temperature is higher than the
|
|
||||||
target temperature the heater will be turned off.
|
|
||||||
|
|
||||||
If away mode is activated the target temperature is sat to a min
|
|
||||||
temperature (min_temp in config). The min temperature is also used
|
|
||||||
as target temperature when no other temperature is specified.
|
|
||||||
|
|
||||||
If the heater is manually turned on, the target temperature will
|
|
||||||
be sat to 100*C. Meaning the thermostat probably will never turn
|
|
||||||
off the heater.
|
|
||||||
If the heater is manually turned off, the target temperature will
|
|
||||||
be sat according to normal rules. (Based on target temperature
|
|
||||||
for given time intervals and the min temperature.)
|
|
||||||
|
|
||||||
A target temperature sat with the set_temperature function will
|
|
||||||
override all other rules for the target temperature.
|
|
||||||
|
|
||||||
Config:
|
|
||||||
|
|
||||||
[thermostat]
|
|
||||||
platform=heat_control
|
|
||||||
|
|
||||||
name = Name of thermostat
|
|
||||||
|
|
||||||
heater = entity_id for heater switch,
|
|
||||||
must be a toggle device
|
|
||||||
|
|
||||||
target_sensor = entity_id for temperature sensor,
|
|
||||||
target_sensor.state must be temperature
|
|
||||||
|
|
||||||
time_temp = start_time-end_time:target_temp,
|
|
||||||
|
|
||||||
min_temp = minimum temperature, used when away mode is
|
|
||||||
active or no other temperature specified.
|
|
||||||
|
|
||||||
Example:
|
|
||||||
[thermostat]
|
|
||||||
platform=heat_control
|
|
||||||
name = Stue
|
|
||||||
heater = switch.Ovn_stue
|
|
||||||
target_sensor = tellstick_sensor.Stue_temperature
|
|
||||||
time_temp = 0700-0745:17,1500-1850:20
|
|
||||||
min_temp = 10
|
|
||||||
|
|
||||||
For the example the heater will turn on at 0700 if the temperature
|
|
||||||
is lower than 17*C away mode is false. Between 0700 and 0745 the
|
|
||||||
target temperature will be 17*C. Between 0745 and 1500 no temperature
|
|
||||||
is specified. so the min_temp of 10*C will be used. From 1500 to 1850
|
|
||||||
the target temperature is 20*, but if away mode is true the target
|
|
||||||
temperature will be sat to 10*C
|
|
||||||
"""
|
"""
|
||||||