Refactor ModbusRegisterSensor class to get hub and configuration (#50234)

* refactor ModbusRegisterSensor to match the ModbusSwitch interface

* Please pylint, mypy etc.

* Remove PLATFORM.

Co-authored-by: jan Iversen <jancasacondor@gmail.com>
This commit is contained in:
Yuriy Sannikov 2021-05-26 20:28:14 +03:00 committed by GitHub
parent 09b9218511
commit 6391d75919
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
5 changed files with 257 additions and 293 deletions

View File

@ -104,6 +104,7 @@ from .const import (
PLATFORMS,
)
from .modbus import async_modbus_setup
from .validators import sensor_schema_validator
_LOGGER = logging.getLogger(__name__)
@ -347,7 +348,9 @@ MODBUS_SCHEMA = vol.Schema(
vol.Optional(CONF_CLIMATES): vol.All(cv.ensure_list, [CLIMATE_SCHEMA]),
vol.Optional(CONF_COVERS): vol.All(cv.ensure_list, [COVERS_SCHEMA]),
vol.Optional(CONF_LIGHTS): vol.All(cv.ensure_list, [LIGHT_SCHEMA]),
vol.Optional(CONF_SENSORS): vol.All(cv.ensure_list, [SENSOR_SCHEMA]),
vol.Optional(CONF_SENSORS): vol.All(
cv.ensure_list, [vol.All(SENSOR_SCHEMA, sensor_schema_validator)]
),
vol.Optional(CONF_SWITCHES): vol.All(cv.ensure_list, [SWITCH_SCHEMA]),
vol.Optional(CONF_FANS): vol.All(cv.ensure_list, [FAN_SCHEMA]),
}

View File

@ -3,99 +3,39 @@ from __future__ import annotations
import logging
import struct
from typing import Any
import voluptuous as vol
from homeassistant.components.sensor import (
DEVICE_CLASSES_SCHEMA,
PLATFORM_SCHEMA,
SensorEntity,
)
from homeassistant.components.sensor import SensorEntity
from homeassistant.const import (
CONF_ADDRESS,
CONF_COUNT,
CONF_DEVICE_CLASS,
CONF_NAME,
CONF_OFFSET,
CONF_SCAN_INTERVAL,
CONF_SENSORS,
CONF_SLAVE,
CONF_STRUCTURE,
CONF_UNIT_OF_MEASUREMENT,
)
from homeassistant.core import HomeAssistant
from homeassistant.helpers import config_validation as cv
from homeassistant.helpers.restore_state import RestoreEntity
from homeassistant.helpers.typing import ConfigType, DiscoveryInfoType
from . import number
from .base_platform import BasePlatform
from .const import (
CALL_TYPE_REGISTER_HOLDING,
CALL_TYPE_REGISTER_INPUT,
CONF_DATA_TYPE,
CONF_HUB,
CONF_INPUT_TYPE,
CONF_PRECISION,
CONF_REGISTER,
CONF_REGISTER_TYPE,
CONF_REGISTERS,
CONF_REVERSE_ORDER,
CONF_SCALE,
CONF_SWAP,
CONF_SWAP_BYTE,
CONF_SWAP_NONE,
CONF_SWAP_WORD,
CONF_SWAP_WORD_BYTE,
DATA_TYPE_CUSTOM,
DATA_TYPE_FLOAT,
DATA_TYPE_INT,
DATA_TYPE_STRING,
DATA_TYPE_UINT,
DEFAULT_HUB,
DEFAULT_SCAN_INTERVAL,
DEFAULT_STRUCT_FORMAT,
MODBUS_DOMAIN,
)
from .modbus import ModbusHub
PARALLEL_UPDATES = 1
_LOGGER = logging.getLogger(__name__)
PLATFORM_SCHEMA = PLATFORM_SCHEMA.extend(
{
vol.Required(CONF_REGISTERS): [
{
vol.Required(CONF_NAME): cv.string,
vol.Required(CONF_REGISTER): cv.positive_int,
vol.Optional(CONF_COUNT, default=1): cv.positive_int,
vol.Optional(CONF_DATA_TYPE, default=DATA_TYPE_INT): vol.In(
[
DATA_TYPE_INT,
DATA_TYPE_UINT,
DATA_TYPE_FLOAT,
DATA_TYPE_STRING,
DATA_TYPE_CUSTOM,
]
),
vol.Optional(CONF_DEVICE_CLASS): DEVICE_CLASSES_SCHEMA,
vol.Optional(CONF_HUB, default=DEFAULT_HUB): cv.string,
vol.Optional(CONF_OFFSET, default=0): number,
vol.Optional(CONF_PRECISION, default=0): cv.positive_int,
vol.Optional(
CONF_REGISTER_TYPE, default=CALL_TYPE_REGISTER_HOLDING
): vol.In([CALL_TYPE_REGISTER_HOLDING, CALL_TYPE_REGISTER_INPUT]),
vol.Optional(CONF_REVERSE_ORDER, default=False): cv.boolean,
vol.Optional(CONF_SCALE, default=1): number,
vol.Optional(CONF_SLAVE): cv.positive_int,
vol.Optional(CONF_STRUCTURE): cv.string,
vol.Optional(CONF_UNIT_OF_MEASUREMENT): cv.string,
}
]
}
)
async def async_setup_platform(
hass: HomeAssistant,
config: ConfigType,
@ -105,92 +45,15 @@ async def async_setup_platform(
"""Set up the Modbus sensors."""
sensors = []
#  check for old config:
if discovery_info is None:
_LOGGER.warning(
"Sensor configuration is deprecated, will be removed in a future release"
)
discovery_info = {
CONF_NAME: "no name",
CONF_SENSORS: config[CONF_REGISTERS],
}
for entry in discovery_info[CONF_SENSORS]:
entry[CONF_ADDRESS] = entry[CONF_REGISTER]
entry[CONF_INPUT_TYPE] = entry[CONF_REGISTER_TYPE]
del entry[CONF_REGISTER]
del entry[CONF_REGISTER_TYPE]
if discovery_info is None: # pragma: no cover
return
for entry in discovery_info[CONF_SENSORS]:
if entry[CONF_DATA_TYPE] == DATA_TYPE_STRING:
structure = str(entry[CONF_COUNT] * 2) + "s"
elif entry[CONF_DATA_TYPE] != DATA_TYPE_CUSTOM:
try:
structure = f">{DEFAULT_STRUCT_FORMAT[entry[CONF_DATA_TYPE]][entry[CONF_COUNT]]}"
except KeyError:
_LOGGER.error(
"Unable to detect data type for %s sensor, try a custom type",
entry[CONF_NAME],
)
continue
else:
structure = entry.get(CONF_STRUCTURE)
hub = hass.data[MODBUS_DOMAIN][discovery_info[CONF_NAME]]
sensors.append(ModbusRegisterSensor(hub, entry))
try:
size = struct.calcsize(structure)
except struct.error as err:
_LOGGER.error("Error in sensor %s structure: %s", entry[CONF_NAME], err)
continue
bytecount = entry[CONF_COUNT] * 2
if bytecount != size:
_LOGGER.error(
"Structure request %d bytes, but %d registers have a size of %d bytes",
size,
entry[CONF_COUNT],
bytecount,
)
continue
if CONF_REVERSE_ORDER in entry:
if entry[CONF_REVERSE_ORDER]:
entry[CONF_SWAP] = CONF_SWAP_WORD
else:
entry[CONF_SWAP] = CONF_SWAP_NONE
del entry[CONF_REVERSE_ORDER]
if entry.get(CONF_SWAP) != CONF_SWAP_NONE:
if entry[CONF_SWAP] == CONF_SWAP_BYTE:
regs_needed = 1
else: # CONF_SWAP_WORD_BYTE, CONF_SWAP_WORD
regs_needed = 2
if (
entry[CONF_COUNT] < regs_needed
or (entry[CONF_COUNT] % regs_needed) != 0
):
_LOGGER.error(
"Error in sensor %s swap(%s) not possible due to count: %d",
entry[CONF_NAME],
entry[CONF_SWAP],
entry[CONF_COUNT],
)
continue
if CONF_HUB in entry:
# from old config!
hub = hass.data[MODBUS_DOMAIN][entry[CONF_HUB]]
else:
hub = hass.data[MODBUS_DOMAIN][discovery_info[CONF_NAME]]
if CONF_SCAN_INTERVAL not in entry:
entry[CONF_SCAN_INTERVAL] = DEFAULT_SCAN_INTERVAL
sensors.append(
ModbusRegisterSensor(
hub,
entry,
structure,
)
)
if not sensors:
return
async_add_entities(sensors)
if len(sensors) > 0:
async_add_entities(sensors)
class ModbusRegisterSensor(BasePlatform, RestoreEntity, SensorEntity):
@ -198,21 +61,18 @@ class ModbusRegisterSensor(BasePlatform, RestoreEntity, SensorEntity):
def __init__(
self,
hub,
entry,
structure,
):
hub: ModbusHub,
entry: dict[str, Any],
) -> None:
"""Initialize the modbus register sensor."""
super().__init__(hub, entry)
self._register = self._address
self._register_type = self._input_type
self._unit_of_measurement = entry.get(CONF_UNIT_OF_MEASUREMENT)
self._count = int(entry[CONF_COUNT])
self._swap = entry[CONF_SWAP]
self._scale = entry[CONF_SCALE]
self._offset = entry[CONF_OFFSET]
self._precision = entry[CONF_PRECISION]
self._structure = structure
self._structure = entry.get(CONF_STRUCTURE)
self._data_type = entry[CONF_DATA_TYPE]
async def async_added_to_hass(self):
@ -252,7 +112,7 @@ class ModbusRegisterSensor(BasePlatform, RestoreEntity, SensorEntity):
# remark "now" is a dummy parameter to avoid problems with
# async_track_time_interval
result = await self._hub.async_pymodbus_call(
self._slave, self._register, self._count, self._register_type
self._slave, self._address, self._count, self._input_type
)
if result is None:
self._available = False

View File

@ -0,0 +1,86 @@
"""Validate Modbus configuration."""
import logging
import struct
from voluptuous import Invalid
from homeassistant.const import CONF_COUNT, CONF_NAME, CONF_STRUCTURE
from .const import (
CONF_DATA_TYPE,
CONF_REVERSE_ORDER,
CONF_SWAP,
CONF_SWAP_BYTE,
CONF_SWAP_NONE,
CONF_SWAP_WORD,
DATA_TYPE_CUSTOM,
DATA_TYPE_STRING,
DEFAULT_STRUCT_FORMAT,
)
_LOGGER = logging.getLogger(__name__)
def sensor_schema_validator(config):
"""Sensor schema validator."""
if config[CONF_DATA_TYPE] == DATA_TYPE_STRING:
structure = str(config[CONF_COUNT] * 2) + "s"
elif config[CONF_DATA_TYPE] != DATA_TYPE_CUSTOM:
try:
structure = (
f">{DEFAULT_STRUCT_FORMAT[config[CONF_DATA_TYPE]][config[CONF_COUNT]]}"
)
except KeyError:
raise Invalid(
f"Unable to detect data type for {config[CONF_NAME]} sensor, try a custom type"
) from KeyError
else:
structure = config.get(CONF_STRUCTURE)
if not structure:
raise Invalid(
f"Error in sensor {config[CONF_NAME]}. The `{CONF_STRUCTURE}` field can not be empty "
f"if the parameter `{CONF_DATA_TYPE}` is set to the `{DATA_TYPE_CUSTOM}`"
)
try:
size = struct.calcsize(structure)
except struct.error as err:
raise Invalid(
f"Error in sensor {config[CONF_NAME]} structure: {str(err)}"
) from err
bytecount = config[CONF_COUNT] * 2
if bytecount != size:
raise Invalid(
f"Structure request {size} bytes, "
f"but {config[CONF_COUNT]} registers have a size of {bytecount} bytes"
)
swap_type = config.get(CONF_SWAP)
if CONF_REVERSE_ORDER in config:
if config[CONF_REVERSE_ORDER]:
swap_type = CONF_SWAP_WORD
else:
swap_type = CONF_SWAP_NONE
del config[CONF_REVERSE_ORDER]
if config.get(CONF_SWAP) != CONF_SWAP_NONE:
if swap_type == CONF_SWAP_BYTE:
regs_needed = 1
else: # CONF_SWAP_WORD_BYTE, CONF_SWAP_WORD
regs_needed = 2
if config[CONF_COUNT] < regs_needed or (config[CONF_COUNT] % regs_needed) != 0:
raise Invalid(
f"Error in sensor {config[CONF_NAME]} swap({swap_type}) "
f"not possible due to the registers "
f"count: {config[CONF_COUNT]}, needed: {regs_needed}"
)
return {
**config,
CONF_STRUCTURE: structure,
CONF_SWAP: swap_type,
}

View File

@ -80,6 +80,7 @@ async def base_test(
config_modbus=None,
scan_interval=None,
expect_init_to_fail=False,
expect_setup_to_fail=False,
):
"""Run test on device for given config."""
@ -131,7 +132,10 @@ async def base_test(
{array_name_discovery: [{**config_device}]}
)
config_device = None
assert await async_setup_component(hass, DOMAIN, config_modbus)
assert (
await async_setup_component(hass, DOMAIN, config_modbus)
is not expect_setup_to_fail
)
await hass.async_block_till_done()
# setup platform old style
@ -151,7 +155,7 @@ async def base_test(
assert await async_setup_component(hass, entity_domain, config_device)
await hass.async_block_till_done()
assert DOMAIN in hass.config.components
assert (DOMAIN in hass.config.components) is not expect_setup_to_fail
if config_device is not None:
entity_id = f"{entity_domain}.{device_name}"
device = hass.states.get(entity_id)
@ -184,6 +188,7 @@ async def base_config_test(
method_discovery=False,
config_modbus=None,
expect_init_to_fail=False,
expect_setup_to_fail=False,
):
"""Check config of device for given config."""
@ -200,6 +205,7 @@ async def base_config_test(
check_config_only=True,
config_modbus=config_modbus,
expect_init_to_fail=expect_init_to_fail,
expect_setup_to_fail=expect_setup_to_fail,
)

View File

@ -9,8 +9,6 @@ from homeassistant.components.modbus.const import (
CONF_DATA_TYPE,
CONF_INPUT_TYPE,
CONF_PRECISION,
CONF_REGISTER,
CONF_REGISTER_TYPE,
CONF_REGISTERS,
CONF_REVERSE_ORDER,
CONF_SCALE,
@ -45,115 +43,58 @@ from tests.common import mock_restore_cache
@pytest.mark.parametrize(
"do_discovery, do_config",
"do_config",
[
(
False,
{
CONF_REGISTER: 51,
},
),
(
False,
{
CONF_REGISTER: 51,
CONF_SLAVE: 10,
CONF_COUNT: 1,
CONF_DATA_TYPE: "int",
CONF_PRECISION: 0,
CONF_SCALE: 1,
CONF_REVERSE_ORDER: False,
CONF_OFFSET: 0,
CONF_REGISTER_TYPE: CALL_TYPE_REGISTER_HOLDING,
CONF_DEVICE_CLASS: "battery",
},
),
(
False,
{
CONF_REGISTER: 51,
CONF_SLAVE: 10,
CONF_COUNT: 1,
CONF_DATA_TYPE: "int",
CONF_PRECISION: 0,
CONF_SCALE: 1,
CONF_REVERSE_ORDER: False,
CONF_OFFSET: 0,
CONF_REGISTER_TYPE: CALL_TYPE_REGISTER_INPUT,
CONF_DEVICE_CLASS: "battery",
},
),
(
True,
{
CONF_ADDRESS: 51,
},
),
(
True,
{
CONF_ADDRESS: 51,
CONF_SLAVE: 10,
CONF_COUNT: 1,
CONF_DATA_TYPE: "int",
CONF_PRECISION: 0,
CONF_SCALE: 1,
CONF_REVERSE_ORDER: False,
CONF_OFFSET: 0,
CONF_INPUT_TYPE: CALL_TYPE_REGISTER_HOLDING,
CONF_DEVICE_CLASS: "battery",
},
),
(
True,
{
CONF_ADDRESS: 51,
CONF_SLAVE: 10,
CONF_COUNT: 1,
CONF_DATA_TYPE: "int",
CONF_PRECISION: 0,
CONF_SCALE: 1,
CONF_REVERSE_ORDER: False,
CONF_OFFSET: 0,
CONF_INPUT_TYPE: CALL_TYPE_REGISTER_INPUT,
CONF_DEVICE_CLASS: "battery",
},
),
(
True,
{
CONF_ADDRESS: 51,
CONF_COUNT: 1,
CONF_SWAP: CONF_SWAP_NONE,
},
),
(
True,
{
CONF_ADDRESS: 51,
CONF_COUNT: 1,
CONF_SWAP: CONF_SWAP_BYTE,
},
),
(
True,
{
CONF_ADDRESS: 51,
CONF_COUNT: 2,
CONF_SWAP: CONF_SWAP_WORD,
},
),
(
True,
{
CONF_ADDRESS: 51,
CONF_COUNT: 2,
CONF_SWAP: CONF_SWAP_WORD_BYTE,
},
),
{
CONF_ADDRESS: 51,
},
{
CONF_ADDRESS: 51,
CONF_SLAVE: 10,
CONF_COUNT: 1,
CONF_DATA_TYPE: "int",
CONF_PRECISION: 0,
CONF_SCALE: 1,
CONF_REVERSE_ORDER: False,
CONF_OFFSET: 0,
CONF_INPUT_TYPE: CALL_TYPE_REGISTER_HOLDING,
CONF_DEVICE_CLASS: "battery",
},
{
CONF_ADDRESS: 51,
CONF_SLAVE: 10,
CONF_COUNT: 1,
CONF_DATA_TYPE: "int",
CONF_PRECISION: 0,
CONF_SCALE: 1,
CONF_REVERSE_ORDER: False,
CONF_OFFSET: 0,
CONF_INPUT_TYPE: CALL_TYPE_REGISTER_INPUT,
CONF_DEVICE_CLASS: "battery",
},
{
CONF_ADDRESS: 51,
CONF_COUNT: 1,
CONF_SWAP: CONF_SWAP_NONE,
},
{
CONF_ADDRESS: 51,
CONF_COUNT: 1,
CONF_SWAP: CONF_SWAP_BYTE,
},
{
CONF_ADDRESS: 51,
CONF_COUNT: 2,
CONF_SWAP: CONF_SWAP_WORD,
},
{
CONF_ADDRESS: 51,
CONF_COUNT: 2,
CONF_SWAP: CONF_SWAP_WORD_BYTE,
},
],
)
async def test_config_sensor(hass, do_discovery, do_config):
async def test_config_sensor(hass, do_config):
"""Run test for sensor."""
sensor_name = "test_sensor"
config_sensor = {
@ -167,36 +108,87 @@ async def test_config_sensor(hass, do_discovery, do_config):
SENSOR_DOMAIN,
CONF_SENSORS,
CONF_REGISTERS,
method_discovery=do_discovery,
method_discovery=True,
)
@pytest.mark.parametrize(
"do_config",
"do_config,error_message",
[
{
CONF_ADDRESS: 1234,
CONF_COUNT: 8,
CONF_PRECISION: 2,
CONF_DATA_TYPE: DATA_TYPE_INT,
},
{
CONF_ADDRESS: 1234,
CONF_COUNT: 8,
CONF_PRECISION: 2,
CONF_DATA_TYPE: DATA_TYPE_CUSTOM,
CONF_STRUCTURE: ">no struct",
},
{
CONF_ADDRESS: 1234,
CONF_COUNT: 2,
CONF_PRECISION: 2,
CONF_DATA_TYPE: DATA_TYPE_CUSTOM,
CONF_STRUCTURE: ">4f",
},
(
{
CONF_ADDRESS: 1234,
CONF_COUNT: 8,
CONF_PRECISION: 2,
CONF_DATA_TYPE: DATA_TYPE_INT,
},
"Unable to detect data type for test_sensor sensor, try a custom type",
),
(
{
CONF_ADDRESS: 1234,
CONF_COUNT: 8,
CONF_PRECISION: 2,
CONF_DATA_TYPE: DATA_TYPE_CUSTOM,
CONF_STRUCTURE: ">no struct",
},
"Error in sensor test_sensor structure: bad char in struct format",
),
(
{
CONF_ADDRESS: 1234,
CONF_COUNT: 2,
CONF_PRECISION: 2,
CONF_DATA_TYPE: DATA_TYPE_CUSTOM,
CONF_STRUCTURE: ">4f",
},
"Structure request 16 bytes, but 2 registers have a size of 4 bytes",
),
(
{
CONF_ADDRESS: 1234,
CONF_DATA_TYPE: DATA_TYPE_CUSTOM,
CONF_COUNT: 4,
CONF_SWAP: CONF_SWAP_NONE,
CONF_STRUCTURE: "invalid",
},
"Error in sensor test_sensor structure: bad char in struct format",
),
(
{
CONF_ADDRESS: 1234,
CONF_DATA_TYPE: DATA_TYPE_CUSTOM,
CONF_COUNT: 4,
CONF_SWAP: CONF_SWAP_NONE,
CONF_STRUCTURE: "",
},
"Error in sensor test_sensor. The `structure` field can not be empty if the parameter `data_type` is set to the `custom`",
),
(
{
CONF_ADDRESS: 1234,
CONF_DATA_TYPE: DATA_TYPE_CUSTOM,
CONF_COUNT: 4,
CONF_SWAP: CONF_SWAP_NONE,
CONF_STRUCTURE: "1s",
},
"Structure request 1 bytes, but 4 registers have a size of 8 bytes",
),
(
{
CONF_ADDRESS: 1234,
CONF_DATA_TYPE: DATA_TYPE_CUSTOM,
CONF_COUNT: 1,
CONF_STRUCTURE: "2s",
CONF_SWAP: CONF_SWAP_WORD,
},
"Error in sensor test_sensor swap(word) not possible due to the registers count: 1, needed: 2",
),
],
)
async def test_config_wrong_struct_sensor(hass, do_config):
async def test_config_wrong_struct_sensor(
hass, caplog, do_config, error_message, mock_pymodbus
):
"""Run test for sensor with wrong struct."""
sensor_name = "test_sensor"
@ -204,6 +196,9 @@ async def test_config_wrong_struct_sensor(hass, do_config):
CONF_NAME: sensor_name,
**do_config,
}
caplog.set_level(logging.WARNING)
caplog.clear()
await base_config_test(
hass,
config_sensor,
@ -212,8 +207,11 @@ async def test_config_wrong_struct_sensor(hass, do_config):
CONF_SENSORS,
None,
method_discovery=True,
expect_setup_to_fail=True,
)
assert error_message in "".join(caplog.messages)
@pytest.mark.parametrize(
"cfg,regs,expected",
@ -592,10 +590,21 @@ async def test_restore_state_sensor(hass):
@pytest.mark.parametrize(
"swap_type",
[CONF_SWAP_WORD, CONF_SWAP_WORD_BYTE],
"swap_type, error_message",
[
(
CONF_SWAP_WORD,
"Error in sensor modbus_test_sensor swap(word) not possible due to the registers count: 1, needed: 2",
),
(
CONF_SWAP_WORD_BYTE,
"Error in sensor modbus_test_sensor swap(word_byte) not possible due to the registers count: 1, needed: 2",
),
],
)
async def test_swap_sensor_wrong_config(hass, caplog, swap_type):
async def test_swap_sensor_wrong_config(
hass, caplog, swap_type, error_message, mock_pymodbus
):
"""Run test for sensor swap."""
sensor_name = "modbus_test_sensor"
config = {
@ -616,9 +625,9 @@ async def test_swap_sensor_wrong_config(hass, caplog, swap_type):
CONF_SENSORS,
None,
method_discovery=True,
expect_init_to_fail=True,
expect_setup_to_fail=True,
)
assert caplog.messages[-1].startswith("Error in sensor " + sensor_name + " swap")
assert error_message in "".join(caplog.messages)