Migrate Fronius to new entity naming style (#74974)

This commit is contained in:
Matthias Alphart 2022-07-11 18:16:29 +02:00 committed by GitHub
parent 4a39087fe7
commit 75abf87611
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
2 changed files with 234 additions and 339 deletions

View File

@ -4,7 +4,6 @@ from __future__ import annotations
from typing import TYPE_CHECKING, Any, Final
from homeassistant.components.sensor import (
DOMAIN as SENSOR_DOMAIN,
SensorDeviceClass,
SensorEntity,
SensorEntityDescription,
@ -109,14 +108,14 @@ INVERTER_ENTITY_DESCRIPTIONS: list[SensorEntityDescription] = [
),
SensorEntityDescription(
key="current_ac",
name="AC current",
name="Current AC",
native_unit_of_measurement=ELECTRIC_CURRENT_AMPERE,
device_class=SensorDeviceClass.CURRENT,
state_class=SensorStateClass.MEASUREMENT,
),
SensorEntityDescription(
key="current_dc",
name="DC current",
name="Current DC",
native_unit_of_measurement=ELECTRIC_CURRENT_AMPERE,
device_class=SensorDeviceClass.CURRENT,
state_class=SensorStateClass.MEASUREMENT,
@ -124,7 +123,7 @@ INVERTER_ENTITY_DESCRIPTIONS: list[SensorEntityDescription] = [
),
SensorEntityDescription(
key="current_dc_2",
name="DC current 2",
name="Current DC 2",
native_unit_of_measurement=ELECTRIC_CURRENT_AMPERE,
device_class=SensorDeviceClass.CURRENT,
state_class=SensorStateClass.MEASUREMENT,
@ -132,14 +131,14 @@ INVERTER_ENTITY_DESCRIPTIONS: list[SensorEntityDescription] = [
),
SensorEntityDescription(
key="power_ac",
name="AC power",
name="Power AC",
native_unit_of_measurement=POWER_WATT,
device_class=SensorDeviceClass.POWER,
state_class=SensorStateClass.MEASUREMENT,
),
SensorEntityDescription(
key="voltage_ac",
name="AC voltage",
name="Voltage AC",
native_unit_of_measurement=ELECTRIC_POTENTIAL_VOLT,
device_class=SensorDeviceClass.VOLTAGE,
state_class=SensorStateClass.MEASUREMENT,
@ -147,7 +146,7 @@ INVERTER_ENTITY_DESCRIPTIONS: list[SensorEntityDescription] = [
),
SensorEntityDescription(
key="voltage_dc",
name="DC voltage",
name="Voltage DC",
native_unit_of_measurement=ELECTRIC_POTENTIAL_VOLT,
device_class=SensorDeviceClass.VOLTAGE,
state_class=SensorStateClass.MEASUREMENT,
@ -155,7 +154,7 @@ INVERTER_ENTITY_DESCRIPTIONS: list[SensorEntityDescription] = [
),
SensorEntityDescription(
key="voltage_dc_2",
name="DC voltage 2",
name="Voltage DC 2",
native_unit_of_measurement=ELECTRIC_POTENTIAL_VOLT,
device_class=SensorDeviceClass.VOLTAGE,
state_class=SensorStateClass.MEASUREMENT,
@ -492,7 +491,7 @@ OHMPILOT_ENTITY_DESCRIPTIONS: list[SensorEntityDescription] = [
),
SensorEntityDescription(
key="temperature_channel_1",
name="Temperature Channel 1",
name="Temperature channel 1",
native_unit_of_measurement=TEMP_CELSIUS,
device_class=SensorDeviceClass.TEMPERATURE,
state_class=SensorStateClass.MEASUREMENT,
@ -541,7 +540,7 @@ POWER_FLOW_ENTITY_DESCRIPTIONS: list[SensorEntityDescription] = [
),
SensorEntityDescription(
key="meter_mode",
name="Mode",
name="Meter mode",
entity_category=EntityCategory.DIAGNOSTIC,
),
SensorEntityDescription(
@ -656,7 +655,8 @@ class _FroniusSensorEntity(CoordinatorEntity["FroniusCoordinatorBase"], SensorEn
"""Defines a Fronius coordinator entity."""
entity_descriptions: list[SensorEntityDescription]
_entity_id_prefix: str
_attr_has_entity_name = True
def __init__(
self,
@ -669,10 +669,6 @@ class _FroniusSensorEntity(CoordinatorEntity["FroniusCoordinatorBase"], SensorEn
self.entity_description = next(
desc for desc in self.entity_descriptions if desc.key == key
)
# default entity_id added 2021.12
# used for migration from non-unique_id entities of previous integration implementation
# when removed after migration period `_entity_id_prefix` will also no longer be needed
self.entity_id = f"{SENSOR_DOMAIN}.{key}_{DOMAIN}_{self._entity_id_prefix}_{coordinator.solar_net.host}"
self.solar_net_id = solar_net_id
self._attr_native_value = self._get_entity_value()
@ -709,7 +705,6 @@ class InverterSensor(_FroniusSensorEntity):
solar_net_id: str,
) -> None:
"""Set up an individual Fronius inverter sensor."""
self._entity_id_prefix = f"inverter_{solar_net_id}"
super().__init__(coordinator, key, solar_net_id)
# device_info created in __init__ from a `GetInverterInfo` request
self._attr_device_info = coordinator.inverter_info.device_info
@ -720,7 +715,6 @@ class LoggerSensor(_FroniusSensorEntity):
"""Defines a Fronius logger device sensor entity."""
entity_descriptions = LOGGER_ENTITY_DESCRIPTIONS
_entity_id_prefix = "logger_info_0"
def __init__(
self,
@ -749,7 +743,6 @@ class MeterSensor(_FroniusSensorEntity):
solar_net_id: str,
) -> None:
"""Set up an individual Fronius meter sensor."""
self._entity_id_prefix = f"meter_{solar_net_id}"
super().__init__(coordinator, key, solar_net_id)
meter_data = self._device_data()
# S0 meters connected directly to inverters respond "n.a." as serial number
@ -782,7 +775,6 @@ class OhmpilotSensor(_FroniusSensorEntity):
solar_net_id: str,
) -> None:
"""Set up an individual Fronius meter sensor."""
self._entity_id_prefix = f"ohmpilot_{solar_net_id}"
super().__init__(coordinator, key, solar_net_id)
device_data = self._device_data()
@ -801,7 +793,6 @@ class PowerFlowSensor(_FroniusSensorEntity):
"""Defines a Fronius power flow sensor entity."""
entity_descriptions = POWER_FLOW_ENTITY_DESCRIPTIONS
_entity_id_prefix = "power_flow_0"
def __init__(
self,
@ -830,7 +821,6 @@ class StorageSensor(_FroniusSensorEntity):
solar_net_id: str,
) -> None:
"""Set up an individual Fronius storage sensor."""
self._entity_id_prefix = f"storage_{solar_net_id}"
super().__init__(coordinator, key, solar_net_id)
storage_data = self._device_data()

View File

@ -30,11 +30,11 @@ async def test_symo_inverter(hass, aioclient_mock):
hass, config_entry.entry_id, FroniusInverterUpdateCoordinator.default_interval
)
assert len(hass.states.async_all(domain_filter=SENSOR_DOMAIN)) == 52
assert_state("sensor.current_dc_fronius_inverter_1_http_fronius", 0)
assert_state("sensor.energy_day_fronius_inverter_1_http_fronius", 10828)
assert_state("sensor.energy_total_fronius_inverter_1_http_fronius", 44186900)
assert_state("sensor.energy_year_fronius_inverter_1_http_fronius", 25507686)
assert_state("sensor.voltage_dc_fronius_inverter_1_http_fronius", 16)
assert_state("sensor.symo_20_current_dc", 0)
assert_state("sensor.symo_20_energy_day", 10828)
assert_state("sensor.symo_20_energy_total", 44186900)
assert_state("sensor.symo_20_energy_year", 25507686)
assert_state("sensor.symo_20_voltage_dc", 16)
# Second test at daytime when inverter is producing
mock_responses(aioclient_mock, night=False)
@ -48,15 +48,15 @@ async def test_symo_inverter(hass, aioclient_mock):
)
assert len(hass.states.async_all(domain_filter=SENSOR_DOMAIN)) == 58
# 4 additional AC entities
assert_state("sensor.current_dc_fronius_inverter_1_http_fronius", 2.19)
assert_state("sensor.energy_day_fronius_inverter_1_http_fronius", 1113)
assert_state("sensor.energy_total_fronius_inverter_1_http_fronius", 44188000)
assert_state("sensor.energy_year_fronius_inverter_1_http_fronius", 25508798)
assert_state("sensor.voltage_dc_fronius_inverter_1_http_fronius", 518)
assert_state("sensor.current_ac_fronius_inverter_1_http_fronius", 5.19)
assert_state("sensor.frequency_ac_fronius_inverter_1_http_fronius", 49.94)
assert_state("sensor.power_ac_fronius_inverter_1_http_fronius", 1190)
assert_state("sensor.voltage_ac_fronius_inverter_1_http_fronius", 227.90)
assert_state("sensor.symo_20_current_dc", 2.19)
assert_state("sensor.symo_20_energy_day", 1113)
assert_state("sensor.symo_20_energy_total", 44188000)
assert_state("sensor.symo_20_energy_year", 25508798)
assert_state("sensor.symo_20_voltage_dc", 518)
assert_state("sensor.symo_20_current_ac", 5.19)
assert_state("sensor.symo_20_frequency_ac", 49.94)
assert_state("sensor.symo_20_power_ac", 1190)
assert_state("sensor.symo_20_voltage_ac", 227.90)
# Third test at nighttime - additional AC entities aren't changed
mock_responses(aioclient_mock, night=True)
@ -64,10 +64,10 @@ async def test_symo_inverter(hass, aioclient_mock):
hass, dt.utcnow() + FroniusInverterUpdateCoordinator.default_interval
)
await hass.async_block_till_done()
assert_state("sensor.current_ac_fronius_inverter_1_http_fronius", 5.19)
assert_state("sensor.frequency_ac_fronius_inverter_1_http_fronius", 49.94)
assert_state("sensor.power_ac_fronius_inverter_1_http_fronius", 1190)
assert_state("sensor.voltage_ac_fronius_inverter_1_http_fronius", 227.90)
assert_state("sensor.symo_20_current_ac", 5.19)
assert_state("sensor.symo_20_frequency_ac", 49.94)
assert_state("sensor.symo_20_power_ac", 1190)
assert_state("sensor.symo_20_voltage_ac", 227.90)
async def test_symo_logger(hass, aioclient_mock):
@ -82,18 +82,9 @@ async def test_symo_logger(hass, aioclient_mock):
await setup_fronius_integration(hass)
assert len(hass.states.async_all(domain_filter=SENSOR_DOMAIN)) == 24
# states are rounded to 4 decimals
assert_state(
"sensor.cash_factor_fronius_logger_info_0_http_fronius",
0.078,
)
assert_state(
"sensor.co2_factor_fronius_logger_info_0_http_fronius",
0.53,
)
assert_state(
"sensor.delivery_factor_fronius_logger_info_0_http_fronius",
0.15,
)
assert_state("sensor.solarnet_grid_export_tariff", 0.078)
assert_state("sensor.solarnet_co2_factor", 0.53)
assert_state("sensor.solarnet_grid_import_tariff", 0.15)
async def test_symo_meter(hass, aioclient_mock):
@ -113,48 +104,38 @@ async def test_symo_meter(hass, aioclient_mock):
)
assert len(hass.states.async_all(domain_filter=SENSOR_DOMAIN)) == 58
# states are rounded to 4 decimals
assert_state("sensor.current_ac_phase_1_fronius_meter_0_http_fronius", 7.755)
assert_state("sensor.current_ac_phase_2_fronius_meter_0_http_fronius", 6.68)
assert_state("sensor.current_ac_phase_3_fronius_meter_0_http_fronius", 10.102)
assert_state(
"sensor.energy_reactive_ac_consumed_fronius_meter_0_http_fronius", 59960790
)
assert_state(
"sensor.energy_reactive_ac_produced_fronius_meter_0_http_fronius", 723160
)
assert_state("sensor.energy_real_ac_minus_fronius_meter_0_http_fronius", 35623065)
assert_state("sensor.energy_real_ac_plus_fronius_meter_0_http_fronius", 15303334)
assert_state("sensor.energy_real_consumed_fronius_meter_0_http_fronius", 15303334)
assert_state("sensor.energy_real_produced_fronius_meter_0_http_fronius", 35623065)
assert_state("sensor.frequency_phase_average_fronius_meter_0_http_fronius", 50)
assert_state("sensor.power_apparent_phase_1_fronius_meter_0_http_fronius", 1772.793)
assert_state("sensor.power_apparent_phase_2_fronius_meter_0_http_fronius", 1527.048)
assert_state("sensor.power_apparent_phase_3_fronius_meter_0_http_fronius", 2333.562)
assert_state("sensor.power_apparent_fronius_meter_0_http_fronius", 5592.57)
assert_state("sensor.power_factor_phase_1_fronius_meter_0_http_fronius", -0.99)
assert_state("sensor.power_factor_phase_2_fronius_meter_0_http_fronius", -0.99)
assert_state("sensor.power_factor_phase_3_fronius_meter_0_http_fronius", 0.99)
assert_state("sensor.power_factor_fronius_meter_0_http_fronius", 1)
assert_state("sensor.power_reactive_phase_1_fronius_meter_0_http_fronius", 51.48)
assert_state("sensor.power_reactive_phase_2_fronius_meter_0_http_fronius", 115.63)
assert_state("sensor.power_reactive_phase_3_fronius_meter_0_http_fronius", -164.24)
assert_state("sensor.power_reactive_fronius_meter_0_http_fronius", 2.87)
assert_state("sensor.power_real_phase_1_fronius_meter_0_http_fronius", 1765.55)
assert_state("sensor.power_real_phase_2_fronius_meter_0_http_fronius", 1515.8)
assert_state("sensor.power_real_phase_3_fronius_meter_0_http_fronius", 2311.22)
assert_state("sensor.power_real_fronius_meter_0_http_fronius", 5592.57)
assert_state("sensor.voltage_ac_phase_1_fronius_meter_0_http_fronius", 228.6)
assert_state("sensor.voltage_ac_phase_2_fronius_meter_0_http_fronius", 228.6)
assert_state("sensor.voltage_ac_phase_3_fronius_meter_0_http_fronius", 231)
assert_state(
"sensor.voltage_ac_phase_to_phase_12_fronius_meter_0_http_fronius", 395.9
)
assert_state(
"sensor.voltage_ac_phase_to_phase_23_fronius_meter_0_http_fronius", 398
)
assert_state(
"sensor.voltage_ac_phase_to_phase_31_fronius_meter_0_http_fronius", 398
)
assert_state("sensor.smart_meter_63a_current_ac_phase_1", 7.755)
assert_state("sensor.smart_meter_63a_current_ac_phase_2", 6.68)
assert_state("sensor.smart_meter_63a_current_ac_phase_3", 10.102)
assert_state("sensor.smart_meter_63a_energy_reactive_ac_consumed", 59960790)
assert_state("sensor.smart_meter_63a_energy_reactive_ac_produced", 723160)
assert_state("sensor.smart_meter_63a_energy_real_ac_minus", 35623065)
assert_state("sensor.smart_meter_63a_energy_real_ac_plus", 15303334)
assert_state("sensor.smart_meter_63a_energy_real_consumed", 15303334)
assert_state("sensor.smart_meter_63a_energy_real_produced", 35623065)
assert_state("sensor.smart_meter_63a_frequency_phase_average", 50)
assert_state("sensor.smart_meter_63a_power_apparent_phase_1", 1772.793)
assert_state("sensor.smart_meter_63a_power_apparent_phase_2", 1527.048)
assert_state("sensor.smart_meter_63a_power_apparent_phase_3", 2333.562)
assert_state("sensor.smart_meter_63a_power_apparent", 5592.57)
assert_state("sensor.smart_meter_63a_power_factor_phase_1", -0.99)
assert_state("sensor.smart_meter_63a_power_factor_phase_2", -0.99)
assert_state("sensor.smart_meter_63a_power_factor_phase_3", 0.99)
assert_state("sensor.smart_meter_63a_power_factor", 1)
assert_state("sensor.smart_meter_63a_power_reactive_phase_1", 51.48)
assert_state("sensor.smart_meter_63a_power_reactive_phase_2", 115.63)
assert_state("sensor.smart_meter_63a_power_reactive_phase_3", -164.24)
assert_state("sensor.smart_meter_63a_power_reactive", 2.87)
assert_state("sensor.smart_meter_63a_power_real_phase_1", 1765.55)
assert_state("sensor.smart_meter_63a_power_real_phase_2", 1515.8)
assert_state("sensor.smart_meter_63a_power_real_phase_3", 2311.22)
assert_state("sensor.smart_meter_63a_power_real", 5592.57)
assert_state("sensor.smart_meter_63a_voltage_ac_phase_1", 228.6)
assert_state("sensor.smart_meter_63a_voltage_ac_phase_2", 228.6)
assert_state("sensor.smart_meter_63a_voltage_ac_phase_3", 231)
assert_state("sensor.smart_meter_63a_voltage_ac_phase_1_2", 395.9)
assert_state("sensor.smart_meter_63a_voltage_ac_phase_2_3", 398)
assert_state("sensor.smart_meter_63a_voltage_ac_phase_3_1", 398)
async def test_symo_power_flow(hass, aioclient_mock):
@ -175,30 +156,12 @@ async def test_symo_power_flow(hass, aioclient_mock):
)
assert len(hass.states.async_all(domain_filter=SENSOR_DOMAIN)) == 52
# states are rounded to 4 decimals
assert_state(
"sensor.energy_day_fronius_power_flow_0_http_fronius",
10828,
)
assert_state(
"sensor.energy_total_fronius_power_flow_0_http_fronius",
44186900,
)
assert_state(
"sensor.energy_year_fronius_power_flow_0_http_fronius",
25507686,
)
assert_state(
"sensor.power_grid_fronius_power_flow_0_http_fronius",
975.31,
)
assert_state(
"sensor.power_load_fronius_power_flow_0_http_fronius",
-975.31,
)
assert_state(
"sensor.relative_autonomy_fronius_power_flow_0_http_fronius",
0,
)
assert_state("sensor.solarnet_energy_day", 10828)
assert_state("sensor.solarnet_energy_total", 44186900)
assert_state("sensor.solarnet_energy_year", 25507686)
assert_state("sensor.solarnet_power_grid", 975.31)
assert_state("sensor.solarnet_power_load", -975.31)
assert_state("sensor.solarnet_relative_autonomy", 0)
# Second test at daytime when inverter is producing
mock_responses(aioclient_mock, night=False)
@ -208,38 +171,14 @@ async def test_symo_power_flow(hass, aioclient_mock):
await hass.async_block_till_done()
# 54 because power_flow `rel_SelfConsumption` and `P_PV` is not `null` anymore
assert len(hass.states.async_all(domain_filter=SENSOR_DOMAIN)) == 54
assert_state(
"sensor.energy_day_fronius_power_flow_0_http_fronius",
1101.7001,
)
assert_state(
"sensor.energy_total_fronius_power_flow_0_http_fronius",
44188000,
)
assert_state(
"sensor.energy_year_fronius_power_flow_0_http_fronius",
25508788,
)
assert_state(
"sensor.power_grid_fronius_power_flow_0_http_fronius",
1703.74,
)
assert_state(
"sensor.power_load_fronius_power_flow_0_http_fronius",
-2814.74,
)
assert_state(
"sensor.power_photovoltaics_fronius_power_flow_0_http_fronius",
1111,
)
assert_state(
"sensor.relative_autonomy_fronius_power_flow_0_http_fronius",
39.4708,
)
assert_state(
"sensor.relative_self_consumption_fronius_power_flow_0_http_fronius",
100,
)
assert_state("sensor.solarnet_energy_day", 1101.7001)
assert_state("sensor.solarnet_energy_total", 44188000)
assert_state("sensor.solarnet_energy_year", 25508788)
assert_state("sensor.solarnet_power_grid", 1703.74)
assert_state("sensor.solarnet_power_load", -2814.74)
assert_state("sensor.solarnet_power_photovoltaics", 1111)
assert_state("sensor.solarnet_relative_autonomy", 39.4708)
assert_state("sensor.solarnet_relative_self_consumption", 100)
async def test_gen24(hass, aioclient_mock):
@ -259,74 +198,60 @@ async def test_gen24(hass, aioclient_mock):
)
assert len(hass.states.async_all(domain_filter=SENSOR_DOMAIN)) == 52
# inverter 1
assert_state("sensor.current_ac_fronius_inverter_1_http_fronius", 0.1589)
assert_state("sensor.current_dc_2_fronius_inverter_1_http_fronius", 0.0754)
assert_state("sensor.status_code_fronius_inverter_1_http_fronius", 7)
assert_state("sensor.current_dc_fronius_inverter_1_http_fronius", 0.0783)
assert_state("sensor.voltage_dc_2_fronius_inverter_1_http_fronius", 403.4312)
assert_state("sensor.power_ac_fronius_inverter_1_http_fronius", 37.3204)
assert_state("sensor.error_code_fronius_inverter_1_http_fronius", 0)
assert_state("sensor.voltage_dc_fronius_inverter_1_http_fronius", 411.3811)
assert_state("sensor.energy_total_fronius_inverter_1_http_fronius", 1530193.42)
assert_state("sensor.inverter_state_fronius_inverter_1_http_fronius", "Running")
assert_state("sensor.voltage_ac_fronius_inverter_1_http_fronius", 234.9168)
assert_state("sensor.frequency_ac_fronius_inverter_1_http_fronius", 49.9917)
assert_state("sensor.inverter_name_current_ac", 0.1589)
assert_state("sensor.inverter_name_current_dc_2", 0.0754)
assert_state("sensor.inverter_name_status_code", 7)
assert_state("sensor.inverter_name_current_dc", 0.0783)
assert_state("sensor.inverter_name_voltage_dc_2", 403.4312)
assert_state("sensor.inverter_name_power_ac", 37.3204)
assert_state("sensor.inverter_name_error_code", 0)
assert_state("sensor.inverter_name_voltage_dc", 411.3811)
assert_state("sensor.inverter_name_energy_total", 1530193.42)
assert_state("sensor.inverter_name_inverter_state", "Running")
assert_state("sensor.inverter_name_voltage_ac", 234.9168)
assert_state("sensor.inverter_name_frequency_ac", 49.9917)
# meter
assert_state("sensor.energy_real_produced_fronius_meter_0_http_fronius", 3863340.0)
assert_state("sensor.energy_real_consumed_fronius_meter_0_http_fronius", 2013105.0)
assert_state("sensor.power_real_fronius_meter_0_http_fronius", 653.1)
assert_state("sensor.frequency_phase_average_fronius_meter_0_http_fronius", 49.9)
assert_state("sensor.meter_location_fronius_meter_0_http_fronius", 0.0)
assert_state("sensor.power_factor_fronius_meter_0_http_fronius", 0.828)
assert_state(
"sensor.energy_reactive_ac_consumed_fronius_meter_0_http_fronius", 88221.0
)
assert_state("sensor.energy_real_ac_minus_fronius_meter_0_http_fronius", 3863340.0)
assert_state("sensor.current_ac_phase_2_fronius_meter_0_http_fronius", 2.33)
assert_state("sensor.voltage_ac_phase_1_fronius_meter_0_http_fronius", 235.9)
assert_state(
"sensor.voltage_ac_phase_to_phase_12_fronius_meter_0_http_fronius", 408.7
)
assert_state("sensor.power_real_phase_2_fronius_meter_0_http_fronius", 294.9)
assert_state("sensor.energy_real_ac_plus_fronius_meter_0_http_fronius", 2013105.0)
assert_state("sensor.voltage_ac_phase_2_fronius_meter_0_http_fronius", 236.1)
assert_state(
"sensor.energy_reactive_ac_produced_fronius_meter_0_http_fronius", 1989125.0
)
assert_state("sensor.voltage_ac_phase_3_fronius_meter_0_http_fronius", 236.9)
assert_state("sensor.power_factor_phase_1_fronius_meter_0_http_fronius", 0.441)
assert_state(
"sensor.voltage_ac_phase_to_phase_23_fronius_meter_0_http_fronius", 409.6
)
assert_state("sensor.current_ac_phase_3_fronius_meter_0_http_fronius", 1.825)
assert_state("sensor.power_factor_phase_3_fronius_meter_0_http_fronius", 0.832)
assert_state("sensor.power_apparent_phase_1_fronius_meter_0_http_fronius", 243.3)
assert_state(
"sensor.voltage_ac_phase_to_phase_31_fronius_meter_0_http_fronius", 409.4
)
assert_state("sensor.power_apparent_phase_2_fronius_meter_0_http_fronius", 323.4)
assert_state("sensor.power_apparent_phase_3_fronius_meter_0_http_fronius", 301.2)
assert_state("sensor.power_real_phase_1_fronius_meter_0_http_fronius", 106.8)
assert_state("sensor.power_factor_phase_2_fronius_meter_0_http_fronius", 0.934)
assert_state("sensor.power_real_phase_3_fronius_meter_0_http_fronius", 251.3)
assert_state("sensor.power_reactive_phase_1_fronius_meter_0_http_fronius", -218.6)
assert_state("sensor.power_reactive_phase_2_fronius_meter_0_http_fronius", -132.8)
assert_state("sensor.power_reactive_phase_3_fronius_meter_0_http_fronius", -166.0)
assert_state("sensor.power_apparent_fronius_meter_0_http_fronius", 868.0)
assert_state("sensor.power_reactive_fronius_meter_0_http_fronius", -517.4)
assert_state("sensor.current_ac_phase_1_fronius_meter_0_http_fronius", 1.145)
assert_state("sensor.smart_meter_ts_65a_3_energy_real_produced", 3863340.0)
assert_state("sensor.smart_meter_ts_65a_3_energy_real_consumed", 2013105.0)
assert_state("sensor.smart_meter_ts_65a_3_power_real", 653.1)
assert_state("sensor.smart_meter_ts_65a_3_frequency_phase_average", 49.9)
assert_state("sensor.smart_meter_ts_65a_3_meter_location", 0.0)
assert_state("sensor.smart_meter_ts_65a_3_power_factor", 0.828)
assert_state("sensor.smart_meter_ts_65a_3_energy_reactive_ac_consumed", 88221.0)
assert_state("sensor.smart_meter_ts_65a_3_energy_real_ac_minus", 3863340.0)
assert_state("sensor.smart_meter_ts_65a_3_current_ac_phase_2", 2.33)
assert_state("sensor.smart_meter_ts_65a_3_voltage_ac_phase_1", 235.9)
assert_state("sensor.smart_meter_ts_65a_3_voltage_ac_phase_1_2", 408.7)
assert_state("sensor.smart_meter_ts_65a_3_power_real_phase_2", 294.9)
assert_state("sensor.smart_meter_ts_65a_3_energy_real_ac_plus", 2013105.0)
assert_state("sensor.smart_meter_ts_65a_3_voltage_ac_phase_2", 236.1)
assert_state("sensor.smart_meter_ts_65a_3_energy_reactive_ac_produced", 1989125.0)
assert_state("sensor.smart_meter_ts_65a_3_voltage_ac_phase_3", 236.9)
assert_state("sensor.smart_meter_ts_65a_3_power_factor_phase_1", 0.441)
assert_state("sensor.smart_meter_ts_65a_3_voltage_ac_phase_2_3", 409.6)
assert_state("sensor.smart_meter_ts_65a_3_current_ac_phase_3", 1.825)
assert_state("sensor.smart_meter_ts_65a_3_power_factor_phase_3", 0.832)
assert_state("sensor.smart_meter_ts_65a_3_power_apparent_phase_1", 243.3)
assert_state("sensor.smart_meter_ts_65a_3_voltage_ac_phase_3_1", 409.4)
assert_state("sensor.smart_meter_ts_65a_3_power_apparent_phase_2", 323.4)
assert_state("sensor.smart_meter_ts_65a_3_power_apparent_phase_3", 301.2)
assert_state("sensor.smart_meter_ts_65a_3_power_real_phase_1", 106.8)
assert_state("sensor.smart_meter_ts_65a_3_power_factor_phase_2", 0.934)
assert_state("sensor.smart_meter_ts_65a_3_power_real_phase_3", 251.3)
assert_state("sensor.smart_meter_ts_65a_3_power_reactive_phase_1", -218.6)
assert_state("sensor.smart_meter_ts_65a_3_power_reactive_phase_2", -132.8)
assert_state("sensor.smart_meter_ts_65a_3_power_reactive_phase_3", -166.0)
assert_state("sensor.smart_meter_ts_65a_3_power_apparent", 868.0)
assert_state("sensor.smart_meter_ts_65a_3_power_reactive", -517.4)
assert_state("sensor.smart_meter_ts_65a_3_current_ac_phase_1", 1.145)
# power_flow
assert_state("sensor.power_grid_fronius_power_flow_0_http_fronius", 658.4)
assert_state(
"sensor.relative_self_consumption_fronius_power_flow_0_http_fronius", 100.0
)
assert_state(
"sensor.power_photovoltaics_fronius_power_flow_0_http_fronius", 62.9481
)
assert_state("sensor.power_load_fronius_power_flow_0_http_fronius", -695.6827)
assert_state("sensor.meter_mode_fronius_power_flow_0_http_fronius", "meter")
assert_state("sensor.relative_autonomy_fronius_power_flow_0_http_fronius", 5.3592)
assert_state("sensor.energy_total_fronius_power_flow_0_http_fronius", 1530193.42)
assert_state("sensor.solarnet_power_grid", 658.4)
assert_state("sensor.solarnet_relative_self_consumption", 100.0)
assert_state("sensor.solarnet_power_photovoltaics", 62.9481)
assert_state("sensor.solarnet_power_load", -695.6827)
assert_state("sensor.solarnet_meter_mode", "meter")
assert_state("sensor.solarnet_relative_autonomy", 5.3592)
assert_state("sensor.solarnet_energy_total", 1530193.42)
async def test_gen24_storage(hass, aioclient_mock):
@ -348,92 +273,74 @@ async def test_gen24_storage(hass, aioclient_mock):
)
assert len(hass.states.async_all(domain_filter=SENSOR_DOMAIN)) == 64
# inverter 1
assert_state("sensor.current_dc_fronius_inverter_1_http_fronius", 0.3952)
assert_state("sensor.voltage_dc_2_fronius_inverter_1_http_fronius", 318.8103)
assert_state("sensor.current_dc_2_fronius_inverter_1_http_fronius", 0.3564)
assert_state("sensor.current_ac_fronius_inverter_1_http_fronius", 1.1087)
assert_state("sensor.power_ac_fronius_inverter_1_http_fronius", 250.9093)
assert_state("sensor.error_code_fronius_inverter_1_http_fronius", 0)
assert_state("sensor.status_code_fronius_inverter_1_http_fronius", 7)
assert_state("sensor.energy_total_fronius_inverter_1_http_fronius", 7512794.0117)
assert_state("sensor.inverter_state_fronius_inverter_1_http_fronius", "Running")
assert_state("sensor.voltage_dc_fronius_inverter_1_http_fronius", 419.1009)
assert_state("sensor.voltage_ac_fronius_inverter_1_http_fronius", 227.354)
assert_state("sensor.frequency_ac_fronius_inverter_1_http_fronius", 49.9816)
assert_state("sensor.gen24_storage_current_dc", 0.3952)
assert_state("sensor.gen24_storage_voltage_dc_2", 318.8103)
assert_state("sensor.gen24_storage_current_dc_2", 0.3564)
assert_state("sensor.gen24_storage_current_ac", 1.1087)
assert_state("sensor.gen24_storage_power_ac", 250.9093)
assert_state("sensor.gen24_storage_error_code", 0)
assert_state("sensor.gen24_storage_status_code", 7)
assert_state("sensor.gen24_storage_energy_total", 7512794.0117)
assert_state("sensor.gen24_storage_inverter_state", "Running")
assert_state("sensor.gen24_storage_voltage_dc", 419.1009)
assert_state("sensor.gen24_storage_voltage_ac", 227.354)
assert_state("sensor.gen24_storage_frequency_ac", 49.9816)
# meter
assert_state("sensor.energy_real_produced_fronius_meter_0_http_fronius", 1705128.0)
assert_state("sensor.power_real_fronius_meter_0_http_fronius", 487.7)
assert_state("sensor.power_factor_fronius_meter_0_http_fronius", 0.698)
assert_state("sensor.energy_real_consumed_fronius_meter_0_http_fronius", 1247204.0)
assert_state("sensor.frequency_phase_average_fronius_meter_0_http_fronius", 49.9)
assert_state("sensor.meter_location_fronius_meter_0_http_fronius", 0.0)
assert_state("sensor.power_reactive_fronius_meter_0_http_fronius", -501.5)
assert_state(
"sensor.energy_reactive_ac_produced_fronius_meter_0_http_fronius", 3266105.0
)
assert_state("sensor.power_real_phase_3_fronius_meter_0_http_fronius", 19.6)
assert_state("sensor.current_ac_phase_3_fronius_meter_0_http_fronius", 0.645)
assert_state("sensor.energy_real_ac_minus_fronius_meter_0_http_fronius", 1705128.0)
assert_state("sensor.power_apparent_phase_2_fronius_meter_0_http_fronius", 383.9)
assert_state("sensor.current_ac_phase_1_fronius_meter_0_http_fronius", 1.701)
assert_state("sensor.current_ac_phase_2_fronius_meter_0_http_fronius", 1.832)
assert_state("sensor.power_apparent_phase_1_fronius_meter_0_http_fronius", 319.5)
assert_state("sensor.voltage_ac_phase_1_fronius_meter_0_http_fronius", 229.4)
assert_state("sensor.power_real_phase_2_fronius_meter_0_http_fronius", 150.0)
assert_state(
"sensor.voltage_ac_phase_to_phase_31_fronius_meter_0_http_fronius", 394.3
)
assert_state("sensor.voltage_ac_phase_2_fronius_meter_0_http_fronius", 225.6)
assert_state(
"sensor.energy_reactive_ac_consumed_fronius_meter_0_http_fronius", 5482.0
)
assert_state("sensor.energy_real_ac_plus_fronius_meter_0_http_fronius", 1247204.0)
assert_state("sensor.power_factor_phase_1_fronius_meter_0_http_fronius", 0.995)
assert_state("sensor.power_factor_phase_3_fronius_meter_0_http_fronius", 0.163)
assert_state("sensor.power_factor_phase_2_fronius_meter_0_http_fronius", 0.389)
assert_state("sensor.power_reactive_phase_1_fronius_meter_0_http_fronius", -31.3)
assert_state("sensor.power_reactive_phase_3_fronius_meter_0_http_fronius", -116.7)
assert_state(
"sensor.voltage_ac_phase_to_phase_12_fronius_meter_0_http_fronius", 396.0
)
assert_state(
"sensor.voltage_ac_phase_to_phase_23_fronius_meter_0_http_fronius", 393.0
)
assert_state("sensor.power_reactive_phase_2_fronius_meter_0_http_fronius", -353.4)
assert_state("sensor.power_real_phase_1_fronius_meter_0_http_fronius", 317.9)
assert_state("sensor.voltage_ac_phase_3_fronius_meter_0_http_fronius", 228.3)
assert_state("sensor.power_apparent_fronius_meter_0_http_fronius", 821.9)
assert_state("sensor.power_apparent_phase_3_fronius_meter_0_http_fronius", 118.4)
assert_state("sensor.smart_meter_ts_65a_3_energy_real_produced", 1705128.0)
assert_state("sensor.smart_meter_ts_65a_3_power_real", 487.7)
assert_state("sensor.smart_meter_ts_65a_3_power_factor", 0.698)
assert_state("sensor.smart_meter_ts_65a_3_energy_real_consumed", 1247204.0)
assert_state("sensor.smart_meter_ts_65a_3_frequency_phase_average", 49.9)
assert_state("sensor.smart_meter_ts_65a_3_meter_location", 0.0)
assert_state("sensor.smart_meter_ts_65a_3_power_reactive", -501.5)
assert_state("sensor.smart_meter_ts_65a_3_energy_reactive_ac_produced", 3266105.0)
assert_state("sensor.smart_meter_ts_65a_3_power_real_phase_3", 19.6)
assert_state("sensor.smart_meter_ts_65a_3_current_ac_phase_3", 0.645)
assert_state("sensor.smart_meter_ts_65a_3_energy_real_ac_minus", 1705128.0)
assert_state("sensor.smart_meter_ts_65a_3_power_apparent_phase_2", 383.9)
assert_state("sensor.smart_meter_ts_65a_3_current_ac_phase_1", 1.701)
assert_state("sensor.smart_meter_ts_65a_3_current_ac_phase_2", 1.832)
assert_state("sensor.smart_meter_ts_65a_3_power_apparent_phase_1", 319.5)
assert_state("sensor.smart_meter_ts_65a_3_voltage_ac_phase_1", 229.4)
assert_state("sensor.smart_meter_ts_65a_3_power_real_phase_2", 150.0)
assert_state("sensor.smart_meter_ts_65a_3_voltage_ac_phase_3_1", 394.3)
assert_state("sensor.smart_meter_ts_65a_3_voltage_ac_phase_2", 225.6)
assert_state("sensor.smart_meter_ts_65a_3_energy_reactive_ac_consumed", 5482.0)
assert_state("sensor.smart_meter_ts_65a_3_energy_real_ac_plus", 1247204.0)
assert_state("sensor.smart_meter_ts_65a_3_power_factor_phase_1", 0.995)
assert_state("sensor.smart_meter_ts_65a_3_power_factor_phase_3", 0.163)
assert_state("sensor.smart_meter_ts_65a_3_power_factor_phase_2", 0.389)
assert_state("sensor.smart_meter_ts_65a_3_power_reactive_phase_1", -31.3)
assert_state("sensor.smart_meter_ts_65a_3_power_reactive_phase_3", -116.7)
assert_state("sensor.smart_meter_ts_65a_3_voltage_ac_phase_1_2", 396.0)
assert_state("sensor.smart_meter_ts_65a_3_voltage_ac_phase_2_3", 393.0)
assert_state("sensor.smart_meter_ts_65a_3_power_reactive_phase_2", -353.4)
assert_state("sensor.smart_meter_ts_65a_3_power_real_phase_1", 317.9)
assert_state("sensor.smart_meter_ts_65a_3_voltage_ac_phase_3", 228.3)
assert_state("sensor.smart_meter_ts_65a_3_power_apparent", 821.9)
assert_state("sensor.smart_meter_ts_65a_3_power_apparent_phase_3", 118.4)
# ohmpilot
assert_state(
"sensor.energy_real_ac_consumed_fronius_ohmpilot_0_http_fronius", 1233295.0
)
assert_state("sensor.power_real_ac_fronius_ohmpilot_0_http_fronius", 0.0)
assert_state("sensor.temperature_channel_1_fronius_ohmpilot_0_http_fronius", 38.9)
assert_state("sensor.state_code_fronius_ohmpilot_0_http_fronius", 0.0)
assert_state(
"sensor.state_message_fronius_ohmpilot_0_http_fronius", "Up and running"
)
assert_state("sensor.ohmpilot_energy_consumed", 1233295.0)
assert_state("sensor.ohmpilot_power", 0.0)
assert_state("sensor.ohmpilot_temperature_channel_1", 38.9)
assert_state("sensor.ohmpilot_state_code", 0.0)
assert_state("sensor.ohmpilot_state_message", "Up and running")
# power_flow
assert_state("sensor.power_grid_fronius_power_flow_0_http_fronius", 2274.9)
assert_state("sensor.power_battery_fronius_power_flow_0_http_fronius", 0.1591)
assert_state("sensor.power_load_fronius_power_flow_0_http_fronius", -2459.3092)
assert_state(
"sensor.relative_self_consumption_fronius_power_flow_0_http_fronius", 100.0
)
assert_state(
"sensor.power_photovoltaics_fronius_power_flow_0_http_fronius", 216.4328
)
assert_state("sensor.relative_autonomy_fronius_power_flow_0_http_fronius", 7.4984)
assert_state("sensor.meter_mode_fronius_power_flow_0_http_fronius", "bidirectional")
assert_state("sensor.energy_total_fronius_power_flow_0_http_fronius", 7512664.4042)
assert_state("sensor.solarnet_power_grid", 2274.9)
assert_state("sensor.solarnet_power_battery", 0.1591)
assert_state("sensor.solarnet_power_load", -2459.3092)
assert_state("sensor.solarnet_relative_self_consumption", 100.0)
assert_state("sensor.solarnet_power_photovoltaics", 216.4328)
assert_state("sensor.solarnet_relative_autonomy", 7.4984)
assert_state("sensor.solarnet_meter_mode", "bidirectional")
assert_state("sensor.solarnet_energy_total", 7512664.4042)
# storage
assert_state("sensor.current_dc_fronius_storage_0_http_fronius", 0.0)
assert_state("sensor.state_of_charge_fronius_storage_0_http_fronius", 4.6)
assert_state("sensor.capacity_maximum_fronius_storage_0_http_fronius", 16588)
assert_state("sensor.temperature_cell_fronius_storage_0_http_fronius", 21.5)
assert_state("sensor.capacity_designed_fronius_storage_0_http_fronius", 16588)
assert_state("sensor.voltage_dc_fronius_storage_0_http_fronius", 0.0)
assert_state("sensor.byd_battery_box_premium_hv_current_dc", 0.0)
assert_state("sensor.byd_battery_box_premium_hv_state_of_charge", 4.6)
assert_state("sensor.byd_battery_box_premium_hv_capacity_maximum", 16588)
assert_state("sensor.byd_battery_box_premium_hv_temperature_cell", 21.5)
assert_state("sensor.byd_battery_box_premium_hv_capacity_designed", 16588)
assert_state("sensor.byd_battery_box_premium_hv_voltage_dc", 0.0)
# Devices
device_registry = dr.async_get(hass)
@ -486,52 +393,50 @@ async def test_primo_s0(hass, aioclient_mock):
)
assert len(hass.states.async_all(domain_filter=SENSOR_DOMAIN)) == 40
# logger
assert_state("sensor.cash_factor_fronius_logger_info_0_http_fronius", 1)
assert_state("sensor.co2_factor_fronius_logger_info_0_http_fronius", 0.53)
assert_state("sensor.delivery_factor_fronius_logger_info_0_http_fronius", 1)
assert_state("sensor.solarnet_grid_export_tariff", 1)
assert_state("sensor.solarnet_co2_factor", 0.53)
assert_state("sensor.solarnet_grid_import_tariff", 1)
# inverter 1
assert_state("sensor.energy_total_fronius_inverter_1_http_fronius", 17114940)
assert_state("sensor.energy_day_fronius_inverter_1_http_fronius", 22504)
assert_state("sensor.voltage_dc_fronius_inverter_1_http_fronius", 452.3)
assert_state("sensor.power_ac_fronius_inverter_1_http_fronius", 862)
assert_state("sensor.error_code_fronius_inverter_1_http_fronius", 0)
assert_state("sensor.current_dc_fronius_inverter_1_http_fronius", 4.23)
assert_state("sensor.status_code_fronius_inverter_1_http_fronius", 7)
assert_state("sensor.energy_year_fronius_inverter_1_http_fronius", 7532755.5)
assert_state("sensor.current_ac_fronius_inverter_1_http_fronius", 3.85)
assert_state("sensor.voltage_ac_fronius_inverter_1_http_fronius", 223.9)
assert_state("sensor.frequency_ac_fronius_inverter_1_http_fronius", 60)
assert_state("sensor.led_color_fronius_inverter_1_http_fronius", 2)
assert_state("sensor.led_state_fronius_inverter_1_http_fronius", 0)
assert_state("sensor.primo_5_0_1_energy_total", 17114940)
assert_state("sensor.primo_5_0_1_energy_day", 22504)
assert_state("sensor.primo_5_0_1_voltage_dc", 452.3)
assert_state("sensor.primo_5_0_1_power_ac", 862)
assert_state("sensor.primo_5_0_1_error_code", 0)
assert_state("sensor.primo_5_0_1_current_dc", 4.23)
assert_state("sensor.primo_5_0_1_status_code", 7)
assert_state("sensor.primo_5_0_1_energy_year", 7532755.5)
assert_state("sensor.primo_5_0_1_current_ac", 3.85)
assert_state("sensor.primo_5_0_1_voltage_ac", 223.9)
assert_state("sensor.primo_5_0_1_frequency_ac", 60)
assert_state("sensor.primo_5_0_1_led_color", 2)
assert_state("sensor.primo_5_0_1_led_state", 0)
# inverter 2
assert_state("sensor.energy_total_fronius_inverter_2_http_fronius", 5796010)
assert_state("sensor.energy_day_fronius_inverter_2_http_fronius", 14237)
assert_state("sensor.voltage_dc_fronius_inverter_2_http_fronius", 329.5)
assert_state("sensor.power_ac_fronius_inverter_2_http_fronius", 296)
assert_state("sensor.error_code_fronius_inverter_2_http_fronius", 0)
assert_state("sensor.current_dc_fronius_inverter_2_http_fronius", 0.97)
assert_state("sensor.status_code_fronius_inverter_2_http_fronius", 7)
assert_state("sensor.energy_year_fronius_inverter_2_http_fronius", 3596193.25)
assert_state("sensor.current_ac_fronius_inverter_2_http_fronius", 1.32)
assert_state("sensor.voltage_ac_fronius_inverter_2_http_fronius", 223.6)
assert_state("sensor.frequency_ac_fronius_inverter_2_http_fronius", 60.01)
assert_state("sensor.led_color_fronius_inverter_2_http_fronius", 2)
assert_state("sensor.led_state_fronius_inverter_2_http_fronius", 0)
assert_state("sensor.primo_3_0_1_energy_total", 5796010)
assert_state("sensor.primo_3_0_1_energy_day", 14237)
assert_state("sensor.primo_3_0_1_voltage_dc", 329.5)
assert_state("sensor.primo_3_0_1_power_ac", 296)
assert_state("sensor.primo_3_0_1_error_code", 0)
assert_state("sensor.primo_3_0_1_current_dc", 0.97)
assert_state("sensor.primo_3_0_1_status_code", 7)
assert_state("sensor.primo_3_0_1_energy_year", 3596193.25)
assert_state("sensor.primo_3_0_1_current_ac", 1.32)
assert_state("sensor.primo_3_0_1_voltage_ac", 223.6)
assert_state("sensor.primo_3_0_1_frequency_ac", 60.01)
assert_state("sensor.primo_3_0_1_led_color", 2)
assert_state("sensor.primo_3_0_1_led_state", 0)
# meter
assert_state("sensor.meter_location_fronius_meter_0_http_fronius", 1)
assert_state("sensor.power_real_fronius_meter_0_http_fronius", -2216.7487)
assert_state("sensor.s0_meter_at_inverter_1_meter_location", 1)
assert_state("sensor.s0_meter_at_inverter_1_power_real", -2216.7487)
# power_flow
assert_state("sensor.power_load_fronius_power_flow_0_http_fronius", -2218.9349)
assert_state("sensor.meter_mode_fronius_power_flow_0_http_fronius", "vague-meter")
assert_state("sensor.power_photovoltaics_fronius_power_flow_0_http_fronius", 1834)
assert_state("sensor.power_grid_fronius_power_flow_0_http_fronius", 384.9349)
assert_state(
"sensor.relative_self_consumption_fronius_power_flow_0_http_fronius", 100
)
assert_state("sensor.relative_autonomy_fronius_power_flow_0_http_fronius", 82.6523)
assert_state("sensor.energy_total_fronius_power_flow_0_http_fronius", 22910919.5)
assert_state("sensor.energy_day_fronius_power_flow_0_http_fronius", 36724)
assert_state("sensor.energy_year_fronius_power_flow_0_http_fronius", 11128933.25)
assert_state("sensor.solarnet_power_load", -2218.9349)
assert_state("sensor.solarnet_meter_mode", "vague-meter")
assert_state("sensor.solarnet_power_photovoltaics", 1834)
assert_state("sensor.solarnet_power_grid", 384.9349)
assert_state("sensor.solarnet_relative_self_consumption", 100)
assert_state("sensor.solarnet_relative_autonomy", 82.6523)
assert_state("sensor.solarnet_energy_total", 22910919.5)
assert_state("sensor.solarnet_energy_day", 36724)
assert_state("sensor.solarnet_energy_year", 11128933.25)
# Devices
device_registry = dr.async_get(hass)