Support HitachiAirToAirHeatPump (ovp:HLinkMainController) in Overkiz integration (#102159)
* Support OVP devices Support OVP devices * Fix coding style * Fix coding style and unnecessary constants * Move fanmodes inside class * Apply suggestions from code review Co-authored-by: Joost Lekkerkerker <joostlek@outlook.com> * Remove duplicate widget * Update homeassistant/components/overkiz/climate_entities/hitachi_air_to_air_heat_pump_ovp.py Co-authored-by: Joost Lekkerkerker <joostlek@outlook.com> * Format ruff * Fix mypy --------- Co-authored-by: Mick Vleeshouwer <mick@imick.nl> Co-authored-by: Joost Lekkerkerker <joostlek@outlook.com>
This commit is contained in:
parent
cac2c46a42
commit
af625a6696
@ -14,6 +14,7 @@ from .atlantic_pass_apc_heating_zone import AtlanticPassAPCHeatingZone
|
||||
from .atlantic_pass_apc_zone_control import AtlanticPassAPCZoneControl
|
||||
from .atlantic_pass_apc_zone_control_zone import AtlanticPassAPCZoneControlZone
|
||||
from .hitachi_air_to_air_heat_pump_hlrrwifi import HitachiAirToAirHeatPumpHLRRWIFI
|
||||
from .hitachi_air_to_air_heat_pump_ovp import HitachiAirToAirHeatPumpOVP
|
||||
from .somfy_heating_temperature_interface import SomfyHeatingTemperatureInterface
|
||||
from .somfy_thermostat import SomfyThermostat
|
||||
from .valve_heating_temperature_interface import ValveHeatingTemperatureInterface
|
||||
@ -56,5 +57,6 @@ WIDGET_AND_CONTROLLABLE_TO_CLIMATE_ENTITY = {
|
||||
WIDGET_AND_PROTOCOL_TO_CLIMATE_ENTITY = {
|
||||
UIWidget.HITACHI_AIR_TO_AIR_HEAT_PUMP: {
|
||||
Protocol.HLRR_WIFI: HitachiAirToAirHeatPumpHLRRWIFI,
|
||||
Protocol.OVP: HitachiAirToAirHeatPumpOVP,
|
||||
},
|
||||
}
|
||||
|
@ -0,0 +1,357 @@
|
||||
"""Support for HitachiAirToAirHeatPump."""
|
||||
from __future__ import annotations
|
||||
|
||||
from typing import Any
|
||||
|
||||
from pyoverkiz.enums import OverkizCommand, OverkizCommandParam, OverkizState
|
||||
|
||||
from homeassistant.components.climate import (
|
||||
FAN_AUTO,
|
||||
FAN_HIGH,
|
||||
FAN_LOW,
|
||||
FAN_MEDIUM,
|
||||
PRESET_NONE,
|
||||
SWING_BOTH,
|
||||
SWING_HORIZONTAL,
|
||||
SWING_OFF,
|
||||
SWING_VERTICAL,
|
||||
ClimateEntity,
|
||||
ClimateEntityFeature,
|
||||
HVACMode,
|
||||
)
|
||||
from homeassistant.const import ATTR_TEMPERATURE, UnitOfTemperature
|
||||
|
||||
from ..const import DOMAIN
|
||||
from ..coordinator import OverkizDataUpdateCoordinator
|
||||
from ..entity import OverkizEntity
|
||||
|
||||
PRESET_HOLIDAY_MODE = "holiday_mode"
|
||||
FAN_SILENT = "silent"
|
||||
TEMP_MIN = 16
|
||||
TEMP_MAX = 32
|
||||
TEMP_AUTO_MIN = 22
|
||||
TEMP_AUTO_MAX = 28
|
||||
AUTO_PIVOT_TEMPERATURE = 25
|
||||
AUTO_TEMPERATURE_CHANGE_MIN = TEMP_AUTO_MIN - AUTO_PIVOT_TEMPERATURE
|
||||
AUTO_TEMPERATURE_CHANGE_MAX = TEMP_AUTO_MAX - AUTO_PIVOT_TEMPERATURE
|
||||
|
||||
OVERKIZ_TO_HVAC_MODES: dict[str, HVACMode] = {
|
||||
OverkizCommandParam.AUTOHEATING: HVACMode.AUTO,
|
||||
OverkizCommandParam.AUTOCOOLING: HVACMode.AUTO,
|
||||
OverkizCommandParam.ON: HVACMode.HEAT,
|
||||
OverkizCommandParam.OFF: HVACMode.OFF,
|
||||
OverkizCommandParam.HEATING: HVACMode.HEAT,
|
||||
OverkizCommandParam.FAN: HVACMode.FAN_ONLY,
|
||||
OverkizCommandParam.DEHUMIDIFY: HVACMode.DRY,
|
||||
OverkizCommandParam.COOLING: HVACMode.COOL,
|
||||
}
|
||||
|
||||
HVAC_MODES_TO_OVERKIZ: dict[HVACMode, str] = {
|
||||
HVACMode.AUTO: OverkizCommandParam.AUTO,
|
||||
HVACMode.HEAT: OverkizCommandParam.HEATING,
|
||||
HVACMode.OFF: OverkizCommandParam.HEATING,
|
||||
HVACMode.FAN_ONLY: OverkizCommandParam.FAN,
|
||||
HVACMode.DRY: OverkizCommandParam.DEHUMIDIFY,
|
||||
HVACMode.COOL: OverkizCommandParam.COOLING,
|
||||
}
|
||||
|
||||
OVERKIZ_TO_SWING_MODES: dict[str, str] = {
|
||||
OverkizCommandParam.BOTH: SWING_BOTH,
|
||||
OverkizCommandParam.HORIZONTAL: SWING_HORIZONTAL,
|
||||
OverkizCommandParam.STOP: SWING_OFF,
|
||||
OverkizCommandParam.VERTICAL: SWING_VERTICAL,
|
||||
}
|
||||
|
||||
SWING_MODES_TO_OVERKIZ = {v: k for k, v in OVERKIZ_TO_SWING_MODES.items()}
|
||||
|
||||
OVERKIZ_TO_FAN_MODES: dict[str, str] = {
|
||||
OverkizCommandParam.AUTO: FAN_AUTO,
|
||||
OverkizCommandParam.HIGH: FAN_HIGH, # fallback, state can be exposed as HIGH, new state = hi
|
||||
OverkizCommandParam.HI: FAN_HIGH,
|
||||
OverkizCommandParam.LOW: FAN_LOW,
|
||||
OverkizCommandParam.LO: FAN_LOW,
|
||||
OverkizCommandParam.MEDIUM: FAN_MEDIUM, # fallback, state can be exposed as MEDIUM, new state = med
|
||||
OverkizCommandParam.MED: FAN_MEDIUM,
|
||||
OverkizCommandParam.SILENT: OverkizCommandParam.SILENT,
|
||||
}
|
||||
|
||||
FAN_MODES_TO_OVERKIZ: dict[str, str] = {
|
||||
FAN_AUTO: OverkizCommandParam.AUTO,
|
||||
FAN_HIGH: OverkizCommandParam.HI,
|
||||
FAN_LOW: OverkizCommandParam.LO,
|
||||
FAN_MEDIUM: OverkizCommandParam.MED,
|
||||
FAN_SILENT: OverkizCommandParam.SILENT,
|
||||
}
|
||||
|
||||
|
||||
class HitachiAirToAirHeatPumpOVP(OverkizEntity, ClimateEntity):
|
||||
"""Representation of Hitachi Air To Air HeatPump."""
|
||||
|
||||
_attr_hvac_modes = [*HVAC_MODES_TO_OVERKIZ]
|
||||
_attr_fan_modes = [*FAN_MODES_TO_OVERKIZ]
|
||||
_attr_preset_modes = [PRESET_NONE, PRESET_HOLIDAY_MODE]
|
||||
_attr_swing_modes = [*SWING_MODES_TO_OVERKIZ]
|
||||
_attr_target_temperature_step = 1.0
|
||||
_attr_temperature_unit = UnitOfTemperature.CELSIUS
|
||||
_attr_translation_key = DOMAIN
|
||||
|
||||
def __init__(
|
||||
self, device_url: str, coordinator: OverkizDataUpdateCoordinator
|
||||
) -> None:
|
||||
"""Init method."""
|
||||
super().__init__(device_url, coordinator)
|
||||
|
||||
self._attr_supported_features = (
|
||||
ClimateEntityFeature.TARGET_TEMPERATURE
|
||||
| ClimateEntityFeature.FAN_MODE
|
||||
| ClimateEntityFeature.PRESET_MODE
|
||||
)
|
||||
|
||||
if self.device.states.get(OverkizState.OVP_SWING):
|
||||
self._attr_supported_features |= ClimateEntityFeature.SWING_MODE
|
||||
|
||||
if self._attr_device_info:
|
||||
self._attr_device_info["manufacturer"] = "Hitachi"
|
||||
|
||||
@property
|
||||
def hvac_mode(self) -> HVACMode:
|
||||
"""Return hvac operation ie. heat, cool mode."""
|
||||
if (
|
||||
main_op_state := self.device.states[OverkizState.OVP_MAIN_OPERATION]
|
||||
) and main_op_state.value_as_str:
|
||||
if main_op_state.value_as_str.lower() == OverkizCommandParam.OFF:
|
||||
return HVACMode.OFF
|
||||
|
||||
if (
|
||||
mode_change_state := self.device.states[OverkizState.OVP_MODE_CHANGE]
|
||||
) and mode_change_state.value_as_str:
|
||||
# The OVP protocol has 'auto cooling' and 'auto heating' values
|
||||
# that are equivalent to the HLRRWIFI protocol without spaces
|
||||
sanitized_value = mode_change_state.value_as_str.replace(" ", "").lower()
|
||||
return OVERKIZ_TO_HVAC_MODES[sanitized_value]
|
||||
|
||||
return HVACMode.OFF
|
||||
|
||||
async def async_set_hvac_mode(self, hvac_mode: HVACMode) -> None:
|
||||
"""Set new target hvac mode."""
|
||||
if hvac_mode == HVACMode.OFF:
|
||||
await self._global_control(main_operation=OverkizCommandParam.OFF)
|
||||
else:
|
||||
await self._global_control(
|
||||
main_operation=OverkizCommandParam.ON,
|
||||
hvac_mode=HVAC_MODES_TO_OVERKIZ[hvac_mode],
|
||||
)
|
||||
|
||||
@property
|
||||
def fan_mode(self) -> str | None:
|
||||
"""Return the fan setting."""
|
||||
if (
|
||||
state := self.device.states[OverkizState.OVP_FAN_SPEED]
|
||||
) and state.value_as_str:
|
||||
return OVERKIZ_TO_FAN_MODES[state.value_as_str]
|
||||
|
||||
return None
|
||||
|
||||
async def async_set_fan_mode(self, fan_mode: str) -> None:
|
||||
"""Set new target fan mode."""
|
||||
await self._global_control(fan_mode=FAN_MODES_TO_OVERKIZ[fan_mode])
|
||||
|
||||
@property
|
||||
def swing_mode(self) -> str | None:
|
||||
"""Return the swing setting."""
|
||||
if (state := self.device.states[OverkizState.OVP_SWING]) and state.value_as_str:
|
||||
return OVERKIZ_TO_SWING_MODES[state.value_as_str]
|
||||
|
||||
return None
|
||||
|
||||
async def async_set_swing_mode(self, swing_mode: str) -> None:
|
||||
"""Set new target swing operation."""
|
||||
await self._global_control(swing_mode=SWING_MODES_TO_OVERKIZ[swing_mode])
|
||||
|
||||
@property
|
||||
def target_temperature(self) -> int | None:
|
||||
"""Return the target temperature."""
|
||||
if (
|
||||
temperature := self.device.states[OverkizState.CORE_TARGET_TEMPERATURE]
|
||||
) and temperature.value_as_int:
|
||||
return temperature.value_as_int
|
||||
|
||||
return None
|
||||
|
||||
@property
|
||||
def current_temperature(self) -> int | None:
|
||||
"""Return current temperature."""
|
||||
if (
|
||||
state := self.device.states[OverkizState.OVP_ROOM_TEMPERATURE]
|
||||
) and state.value_as_int:
|
||||
return state.value_as_int
|
||||
|
||||
return None
|
||||
|
||||
async def async_set_temperature(self, **kwargs: Any) -> None:
|
||||
"""Set new temperature."""
|
||||
await self._global_control(target_temperature=int(kwargs[ATTR_TEMPERATURE]))
|
||||
|
||||
@property
|
||||
def preset_mode(self) -> str | None:
|
||||
"""Return the current preset mode, e.g., home, away, temp."""
|
||||
if (
|
||||
state := self.device.states[OverkizState.CORE_HOLIDAYS_MODE]
|
||||
) and state.value_as_str:
|
||||
if state.value_as_str == OverkizCommandParam.ON:
|
||||
return PRESET_HOLIDAY_MODE
|
||||
|
||||
if state.value_as_str == OverkizCommandParam.OFF:
|
||||
return PRESET_NONE
|
||||
|
||||
return None
|
||||
|
||||
async def async_set_preset_mode(self, preset_mode: str) -> None:
|
||||
"""Set new preset mode."""
|
||||
if preset_mode == PRESET_HOLIDAY_MODE:
|
||||
await self.executor.async_execute_command(
|
||||
OverkizCommand.SET_HOLIDAYS,
|
||||
OverkizCommandParam.ON,
|
||||
)
|
||||
if preset_mode == PRESET_NONE:
|
||||
await self.executor.async_execute_command(
|
||||
OverkizCommand.SET_HOLIDAYS,
|
||||
OverkizCommandParam.OFF,
|
||||
)
|
||||
|
||||
# OVP has this property to control the unit's timer mode
|
||||
@property
|
||||
def auto_manu_mode(self) -> str | None:
|
||||
"""Return auto/manu mode."""
|
||||
if (
|
||||
state := self.device.states[OverkizState.CORE_AUTO_MANU_MODE]
|
||||
) and state.value_as_str:
|
||||
return state.value_as_str
|
||||
return None
|
||||
|
||||
# OVP has this property to control the target temperature delta in auto mode
|
||||
@property
|
||||
def temperature_change(self) -> int | None:
|
||||
"""Return temperature change state."""
|
||||
if (
|
||||
state := self.device.states[OverkizState.OVP_TEMPERATURE_CHANGE]
|
||||
) and state.value_as_int:
|
||||
return state.value_as_int
|
||||
|
||||
return None
|
||||
|
||||
@property
|
||||
def min_temp(self) -> float:
|
||||
"""Return the minimum temperature."""
|
||||
if self.hvac_mode == HVACMode.AUTO:
|
||||
return TEMP_AUTO_MIN
|
||||
return TEMP_MIN
|
||||
|
||||
@property
|
||||
def max_temp(self) -> float:
|
||||
"""Return the maximum temperature."""
|
||||
if self.hvac_mode == HVACMode.AUTO:
|
||||
return TEMP_AUTO_MAX
|
||||
return TEMP_MAX
|
||||
|
||||
def _control_backfill(
|
||||
self, value: str | None, state_name: str, fallback_value: str
|
||||
) -> str:
|
||||
"""Return a parameter value which will be accepted in a command by Overkiz.
|
||||
|
||||
Overkiz doesn't accept commands with undefined parameters. This function
|
||||
is guaranteed to return a `str` which is the provided `value` if set, or
|
||||
the current device state if set, or the provided `fallback_value` otherwise.
|
||||
"""
|
||||
if value:
|
||||
return value
|
||||
if (state := self.device.states[state_name]) is not None and (
|
||||
value := state.value_as_str
|
||||
) is not None:
|
||||
return value
|
||||
return fallback_value
|
||||
|
||||
async def _global_control(
|
||||
self,
|
||||
main_operation: str | None = None,
|
||||
target_temperature: int | None = None,
|
||||
fan_mode: str | None = None,
|
||||
hvac_mode: str | None = None,
|
||||
swing_mode: str | None = None,
|
||||
leave_home: str | None = None,
|
||||
) -> None:
|
||||
"""Execute globalControl command with all parameters.
|
||||
|
||||
There is no option to only set a single parameter, without passing
|
||||
all other values.
|
||||
"""
|
||||
|
||||
main_operation = self._control_backfill(
|
||||
main_operation, OverkizState.OVP_MAIN_OPERATION, OverkizCommandParam.ON
|
||||
)
|
||||
fan_mode = self._control_backfill(
|
||||
fan_mode,
|
||||
OverkizState.OVP_FAN_SPEED,
|
||||
OverkizCommandParam.AUTO,
|
||||
)
|
||||
hvac_mode = self._control_backfill(
|
||||
hvac_mode,
|
||||
OverkizState.OVP_MODE_CHANGE,
|
||||
OverkizCommandParam.AUTO,
|
||||
).lower() # Overkiz returns uppercase states that are not acceptable commands
|
||||
if hvac_mode.replace(" ", "") in [
|
||||
# Overkiz returns compound states like 'auto cooling' or 'autoHeating'
|
||||
# that are not valid commands and need to be mapped to 'auto'
|
||||
OverkizCommandParam.AUTOCOOLING,
|
||||
OverkizCommandParam.AUTOHEATING,
|
||||
]:
|
||||
hvac_mode = OverkizCommandParam.AUTO
|
||||
|
||||
swing_mode = self._control_backfill(
|
||||
swing_mode,
|
||||
OverkizState.OVP_SWING,
|
||||
OverkizCommandParam.STOP,
|
||||
)
|
||||
|
||||
# AUTO_MANU parameter is not controlled by HA and is turned "off" when the device is on Holiday mode
|
||||
auto_manu_mode = self._control_backfill(
|
||||
None, OverkizState.CORE_AUTO_MANU_MODE, OverkizCommandParam.MANU
|
||||
)
|
||||
if self.preset_mode == PRESET_HOLIDAY_MODE:
|
||||
auto_manu_mode = OverkizCommandParam.OFF
|
||||
|
||||
# In all the hvac modes except AUTO, the temperature command parameter is the target temperature
|
||||
temperature_command = None
|
||||
target_temperature = target_temperature or self.target_temperature
|
||||
if hvac_mode == OverkizCommandParam.AUTO:
|
||||
# In hvac mode AUTO, the temperature command parameter is a temperature_change
|
||||
# which is the delta between a pivot temperature (25) and the target temperature
|
||||
temperature_change = 0
|
||||
|
||||
if target_temperature:
|
||||
temperature_change = target_temperature - AUTO_PIVOT_TEMPERATURE
|
||||
elif self.temperature_change:
|
||||
temperature_change = self.temperature_change
|
||||
|
||||
# Keep temperature_change in the API accepted range
|
||||
temperature_change = min(
|
||||
max(temperature_change, AUTO_TEMPERATURE_CHANGE_MIN),
|
||||
AUTO_TEMPERATURE_CHANGE_MAX,
|
||||
)
|
||||
|
||||
temperature_command = temperature_change
|
||||
else:
|
||||
# In other modes, the temperature command is the target temperature
|
||||
temperature_command = target_temperature
|
||||
|
||||
command_data = [
|
||||
main_operation, # Main Operation
|
||||
temperature_command, # Temperature Command
|
||||
fan_mode, # Fan Mode
|
||||
hvac_mode, # Mode
|
||||
auto_manu_mode, # Auto Manu Mode
|
||||
]
|
||||
|
||||
await self.executor.async_execute_command(
|
||||
OverkizCommand.GLOBAL_CONTROL, command_data
|
||||
)
|
Loading…