mirror of
https://github.com/home-assistant/core.git
synced 2025-07-16 09:47:13 +00:00
Read Modbus climate current temp from input register (#31944)
This commit is contained in:
parent
b73531b2fc
commit
af67bb0df3
@ -27,6 +27,7 @@ _LOGGER = logging.getLogger(__name__)
|
||||
|
||||
CONF_TARGET_TEMP = "target_temp_register"
|
||||
CONF_CURRENT_TEMP = "current_temp_register"
|
||||
CONF_CURRENT_TEMP_REGISTER_TYPE = "current_temp_register_type"
|
||||
CONF_DATA_TYPE = "data_type"
|
||||
CONF_COUNT = "data_count"
|
||||
CONF_PRECISION = "precision"
|
||||
@ -42,6 +43,9 @@ CONF_STEP = "temp_step"
|
||||
SUPPORT_FLAGS = SUPPORT_TARGET_TEMPERATURE
|
||||
HVAC_MODES = [HVAC_MODE_AUTO]
|
||||
|
||||
DEFAULT_REGISTER_TYPE_HOLDING = "holding"
|
||||
DEFAULT_REGISTER_TYPE_INPUT = "input"
|
||||
|
||||
PLATFORM_SCHEMA = PLATFORM_SCHEMA.extend(
|
||||
{
|
||||
vol.Required(CONF_CURRENT_TEMP): cv.positive_int,
|
||||
@ -49,6 +53,9 @@ PLATFORM_SCHEMA = PLATFORM_SCHEMA.extend(
|
||||
vol.Required(CONF_SLAVE): cv.positive_int,
|
||||
vol.Required(CONF_TARGET_TEMP): cv.positive_int,
|
||||
vol.Optional(CONF_COUNT, default=2): cv.positive_int,
|
||||
vol.Optional(
|
||||
CONF_CURRENT_TEMP_REGISTER_TYPE, default=DEFAULT_REGISTER_TYPE_HOLDING
|
||||
): vol.In([DEFAULT_REGISTER_TYPE_HOLDING, DEFAULT_REGISTER_TYPE_INPUT]),
|
||||
vol.Optional(CONF_DATA_TYPE, default=DATA_TYPE_FLOAT): vol.In(
|
||||
[DATA_TYPE_INT, DATA_TYPE_UINT, DATA_TYPE_FLOAT]
|
||||
),
|
||||
@ -66,20 +73,21 @@ PLATFORM_SCHEMA = PLATFORM_SCHEMA.extend(
|
||||
|
||||
def setup_platform(hass, config, add_entities, discovery_info=None):
|
||||
"""Set up the Modbus Thermostat Platform."""
|
||||
name = config.get(CONF_NAME)
|
||||
modbus_slave = config.get(CONF_SLAVE)
|
||||
target_temp_register = config.get(CONF_TARGET_TEMP)
|
||||
current_temp_register = config.get(CONF_CURRENT_TEMP)
|
||||
data_type = config.get(CONF_DATA_TYPE)
|
||||
count = config.get(CONF_COUNT)
|
||||
precision = config.get(CONF_PRECISION)
|
||||
scale = config.get(CONF_SCALE)
|
||||
offset = config.get(CONF_OFFSET)
|
||||
unit = config.get(CONF_UNIT)
|
||||
max_temp = config.get(CONF_MAX_TEMP)
|
||||
min_temp = config.get(CONF_MIN_TEMP)
|
||||
temp_step = config.get(CONF_STEP)
|
||||
hub_name = config.get(CONF_HUB)
|
||||
name = config[CONF_NAME]
|
||||
modbus_slave = config[CONF_SLAVE]
|
||||
target_temp_register = config[CONF_TARGET_TEMP]
|
||||
current_temp_register = config[CONF_CURRENT_TEMP]
|
||||
current_temp_register_type = config[CONF_CURRENT_TEMP_REGISTER_TYPE]
|
||||
data_type = config[CONF_DATA_TYPE]
|
||||
count = config[CONF_COUNT]
|
||||
precision = config[CONF_PRECISION]
|
||||
scale = config[CONF_SCALE]
|
||||
offset = config[CONF_OFFSET]
|
||||
unit = config[CONF_UNIT]
|
||||
max_temp = config[CONF_MAX_TEMP]
|
||||
min_temp = config[CONF_MIN_TEMP]
|
||||
temp_step = config[CONF_STEP]
|
||||
hub_name = config[CONF_HUB]
|
||||
hub = hass.data[MODBUS_DOMAIN][hub_name]
|
||||
|
||||
add_entities(
|
||||
@ -90,6 +98,7 @@ def setup_platform(hass, config, add_entities, discovery_info=None):
|
||||
modbus_slave,
|
||||
target_temp_register,
|
||||
current_temp_register,
|
||||
current_temp_register_type,
|
||||
data_type,
|
||||
count,
|
||||
precision,
|
||||
@ -115,6 +124,7 @@ class ModbusThermostat(ClimateDevice):
|
||||
modbus_slave,
|
||||
target_temp_register,
|
||||
current_temp_register,
|
||||
current_temp_register_type,
|
||||
data_type,
|
||||
count,
|
||||
precision,
|
||||
@ -131,6 +141,7 @@ class ModbusThermostat(ClimateDevice):
|
||||
self._slave = modbus_slave
|
||||
self._target_temperature_register = target_temp_register
|
||||
self._current_temperature_register = current_temp_register
|
||||
self._current_temperature_register_type = current_temp_register_type
|
||||
self._target_temperature = None
|
||||
self._current_temperature = None
|
||||
self._data_type = data_type
|
||||
@ -161,10 +172,10 @@ class ModbusThermostat(ClimateDevice):
|
||||
def update(self):
|
||||
"""Update Target & Current Temperature."""
|
||||
self._target_temperature = self._read_register(
|
||||
self._target_temperature_register
|
||||
DEFAULT_REGISTER_TYPE_HOLDING, self._target_temperature_register
|
||||
)
|
||||
self._current_temperature = self._read_register(
|
||||
self._current_temperature_register
|
||||
self._current_temperature_register_type, self._current_temperature_register
|
||||
)
|
||||
|
||||
@property
|
||||
@ -228,9 +239,14 @@ class ModbusThermostat(ClimateDevice):
|
||||
"""Return True if entity is available."""
|
||||
return self._available
|
||||
|
||||
def _read_register(self, register) -> Optional[float]:
|
||||
"""Read holding register using the Modbus hub slave."""
|
||||
def _read_register(self, register_type, register) -> Optional[float]:
|
||||
"""Read register using the Modbus hub slave."""
|
||||
try:
|
||||
if register_type == DEFAULT_REGISTER_TYPE_INPUT:
|
||||
result = self._hub.read_input_registers(
|
||||
self._slave, register, self._count
|
||||
)
|
||||
else:
|
||||
result = self._hub.read_holding_registers(
|
||||
self._slave, register, self._count
|
||||
)
|
||||
|
Loading…