From f6d2f6117a0a4067fd3ff707a34c7dea0a63c84b Mon Sep 17 00:00:00 2001 From: G Johansson Date: Sat, 3 Feb 2024 21:52:33 -0500 Subject: [PATCH] Fix overkiz climate feature flags for valve heating (#109582) * Fix overkiz climate feature flags for valve heating * Update homeassistant/components/overkiz/climate_entities/valve_heating_temperature_interface.py --- .../climate_entities/valve_heating_temperature_interface.py | 5 +---- 1 file changed, 1 insertion(+), 4 deletions(-) diff --git a/homeassistant/components/overkiz/climate_entities/valve_heating_temperature_interface.py b/homeassistant/components/overkiz/climate_entities/valve_heating_temperature_interface.py index 79c360a5f93..7b7493a37bb 100644 --- a/homeassistant/components/overkiz/climate_entities/valve_heating_temperature_interface.py +++ b/homeassistant/components/overkiz/climate_entities/valve_heating_temperature_interface.py @@ -51,10 +51,7 @@ class ValveHeatingTemperatureInterface(OverkizEntity, ClimateEntity): _attr_hvac_modes = [HVACMode.HEAT] _attr_preset_modes = [*PRESET_MODE_TO_OVERKIZ] _attr_supported_features = ( - ClimateEntityFeature.PRESET_MODE - | ClimateEntityFeature.TARGET_TEMPERATURE - | ClimateEntityFeature.TURN_OFF - | ClimateEntityFeature.TURN_ON + ClimateEntityFeature.PRESET_MODE | ClimateEntityFeature.TARGET_TEMPERATURE ) _attr_temperature_unit = UnitOfTemperature.CELSIUS _attr_translation_key = DOMAIN