mirror of
https://github.com/home-assistant/core.git
synced 2025-07-12 15:57:06 +00:00
Pilight receive match fix for bug 4637 (#4639)
* Pilight: dont protocol as list in COMMAND_SCHEMA As described in bug #4637 the protocol should not be wrapped in a list in the spec of COMMAND_SCHEMA because this causes the component to never successfully match any received rf code. As pointed ot in PR #4639 the easiest way to do this, is to not derive COMMAND_SCHEMA from RF_CODE_SCHEMA and specify protocol as simple string there. This fixes bug #4637. Signed-off-by: Jan Losinski <losinski@wh2.tu-dresden.de> * Pilight: Add "unitcode" to command schema. This adds "unitcode" to the COMMAND_SCHEMA. It is used for example in the brennenstuhl protocol of pilight. Signed-off-by: Jan Losinski <losinski@wh2.tu-dresden.de>
This commit is contained in:
parent
c90a1b9760
commit
f78246e686
@ -11,7 +11,8 @@ import voluptuous as vol
|
|||||||
import homeassistant.helpers.config_validation as cv
|
import homeassistant.helpers.config_validation as cv
|
||||||
import homeassistant.components.pilight as pilight
|
import homeassistant.components.pilight as pilight
|
||||||
from homeassistant.components.switch import (SwitchDevice, PLATFORM_SCHEMA)
|
from homeassistant.components.switch import (SwitchDevice, PLATFORM_SCHEMA)
|
||||||
from homeassistant.const import (CONF_NAME, CONF_ID, CONF_SWITCHES, CONF_STATE)
|
from homeassistant.const import (CONF_NAME, CONF_ID, CONF_SWITCHES, CONF_STATE,
|
||||||
|
CONF_PROTOCOL)
|
||||||
|
|
||||||
_LOGGER = logging.getLogger(__name__)
|
_LOGGER = logging.getLogger(__name__)
|
||||||
|
|
||||||
@ -21,13 +22,16 @@ CONF_ON_CODE = 'on_code'
|
|||||||
CONF_ON_CODE_RECIEVE = 'on_code_receive'
|
CONF_ON_CODE_RECIEVE = 'on_code_receive'
|
||||||
CONF_SYSTEMCODE = 'systemcode'
|
CONF_SYSTEMCODE = 'systemcode'
|
||||||
CONF_UNIT = 'unit'
|
CONF_UNIT = 'unit'
|
||||||
|
CONF_UNITCODE = 'unitcode'
|
||||||
|
|
||||||
DEPENDENCIES = ['pilight']
|
DEPENDENCIES = ['pilight']
|
||||||
|
|
||||||
COMMAND_SCHEMA = pilight.RF_CODE_SCHEMA.extend({
|
COMMAND_SCHEMA = vol.Schema({
|
||||||
|
vol.Optional(CONF_PROTOCOL): cv.string,
|
||||||
vol.Optional('on'): cv.positive_int,
|
vol.Optional('on'): cv.positive_int,
|
||||||
vol.Optional('off'): cv.positive_int,
|
vol.Optional('off'): cv.positive_int,
|
||||||
vol.Optional(CONF_UNIT): cv.positive_int,
|
vol.Optional(CONF_UNIT): cv.positive_int,
|
||||||
|
vol.Optional(CONF_UNITCODE): cv.positive_int,
|
||||||
vol.Optional(CONF_ID): cv.positive_int,
|
vol.Optional(CONF_ID): cv.positive_int,
|
||||||
vol.Optional(CONF_STATE): cv.string,
|
vol.Optional(CONF_STATE): cv.string,
|
||||||
vol.Optional(CONF_SYSTEMCODE): cv.positive_int,
|
vol.Optional(CONF_SYSTEMCODE): cv.positive_int,
|
||||||
|