mirror of
https://github.com/home-assistant/core.git
synced 2025-05-07 15:39:18 +00:00

current_average_demand and maximum_demand_current_month are missing a state class, which gives errors in the statistics tab in HA. So adding them to the sensor.
827 lines
30 KiB
Python
827 lines
30 KiB
Python
"""Support for Dutch Smart Meter (also known as Smartmeter or P1 port)."""
|
|
from __future__ import annotations
|
|
|
|
import asyncio
|
|
from asyncio import CancelledError
|
|
from collections.abc import Callable
|
|
from contextlib import suppress
|
|
from dataclasses import dataclass
|
|
from datetime import timedelta
|
|
from functools import partial
|
|
|
|
from dsmr_parser import obis_references
|
|
from dsmr_parser.clients.protocol import create_dsmr_reader, create_tcp_dsmr_reader
|
|
from dsmr_parser.clients.rfxtrx_protocol import (
|
|
create_rfxtrx_dsmr_reader,
|
|
create_rfxtrx_tcp_dsmr_reader,
|
|
)
|
|
from dsmr_parser.objects import DSMRObject
|
|
import serial
|
|
|
|
from homeassistant.components.sensor import (
|
|
SensorDeviceClass,
|
|
SensorEntity,
|
|
SensorEntityDescription,
|
|
SensorStateClass,
|
|
)
|
|
from homeassistant.config_entries import ConfigEntry
|
|
from homeassistant.const import (
|
|
CONF_HOST,
|
|
CONF_PORT,
|
|
CONF_PROTOCOL,
|
|
EVENT_HOMEASSISTANT_STOP,
|
|
EntityCategory,
|
|
UnitOfEnergy,
|
|
UnitOfVolume,
|
|
)
|
|
from homeassistant.core import CoreState, Event, HomeAssistant, callback
|
|
from homeassistant.helpers import device_registry as dr, entity_registry as er
|
|
from homeassistant.helpers.device_registry import DeviceInfo
|
|
from homeassistant.helpers.dispatcher import (
|
|
async_dispatcher_connect,
|
|
async_dispatcher_send,
|
|
)
|
|
from homeassistant.helpers.entity_platform import AddEntitiesCallback
|
|
from homeassistant.helpers.typing import StateType
|
|
from homeassistant.util import Throttle
|
|
|
|
from .const import (
|
|
CONF_DSMR_VERSION,
|
|
CONF_SERIAL_ID,
|
|
CONF_SERIAL_ID_GAS,
|
|
CONF_TIME_BETWEEN_UPDATE,
|
|
DATA_TASK,
|
|
DEFAULT_PRECISION,
|
|
DEFAULT_RECONNECT_INTERVAL,
|
|
DEFAULT_TIME_BETWEEN_UPDATE,
|
|
DEVICE_NAME_ELECTRICITY,
|
|
DEVICE_NAME_GAS,
|
|
DEVICE_NAME_WATER,
|
|
DOMAIN,
|
|
DSMR_PROTOCOL,
|
|
LOGGER,
|
|
)
|
|
|
|
EVENT_FIRST_TELEGRAM = "dsmr_first_telegram_{}"
|
|
|
|
UNIT_CONVERSION = {"m3": UnitOfVolume.CUBIC_METERS}
|
|
|
|
|
|
@dataclass(frozen=True, kw_only=True)
|
|
class DSMRSensorEntityDescription(SensorEntityDescription):
|
|
"""Represents an DSMR Sensor."""
|
|
|
|
dsmr_versions: set[str] | None = None
|
|
is_gas: bool = False
|
|
is_water: bool = False
|
|
obis_reference: str
|
|
|
|
|
|
SENSORS: tuple[DSMRSensorEntityDescription, ...] = (
|
|
DSMRSensorEntityDescription(
|
|
key="timestamp",
|
|
obis_reference=obis_references.P1_MESSAGE_TIMESTAMP,
|
|
device_class=SensorDeviceClass.TIMESTAMP,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
entity_registry_enabled_default=False,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="current_electricity_usage",
|
|
translation_key="current_electricity_usage",
|
|
obis_reference=obis_references.CURRENT_ELECTRICITY_USAGE,
|
|
device_class=SensorDeviceClass.POWER,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="current_electricity_delivery",
|
|
translation_key="current_electricity_delivery",
|
|
obis_reference=obis_references.CURRENT_ELECTRICITY_DELIVERY,
|
|
device_class=SensorDeviceClass.POWER,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="electricity_active_tariff",
|
|
translation_key="electricity_active_tariff",
|
|
obis_reference=obis_references.ELECTRICITY_ACTIVE_TARIFF,
|
|
dsmr_versions={"2.2", "4", "5", "5B", "5L"},
|
|
device_class=SensorDeviceClass.ENUM,
|
|
options=["low", "normal"],
|
|
icon="mdi:flash",
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="electricity_used_tariff_1",
|
|
translation_key="electricity_used_tariff_1",
|
|
obis_reference=obis_references.ELECTRICITY_USED_TARIFF_1,
|
|
dsmr_versions={"2.2", "4", "5", "5B", "5L"},
|
|
device_class=SensorDeviceClass.ENERGY,
|
|
state_class=SensorStateClass.TOTAL_INCREASING,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="electricity_used_tariff_2",
|
|
translation_key="electricity_used_tariff_2",
|
|
obis_reference=obis_references.ELECTRICITY_USED_TARIFF_2,
|
|
dsmr_versions={"2.2", "4", "5", "5B", "5L"},
|
|
device_class=SensorDeviceClass.ENERGY,
|
|
state_class=SensorStateClass.TOTAL_INCREASING,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="electricity_delivered_tariff_1",
|
|
translation_key="electricity_delivered_tariff_1",
|
|
obis_reference=obis_references.ELECTRICITY_DELIVERED_TARIFF_1,
|
|
dsmr_versions={"2.2", "4", "5", "5B", "5L"},
|
|
device_class=SensorDeviceClass.ENERGY,
|
|
state_class=SensorStateClass.TOTAL_INCREASING,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="electricity_delivered_tariff_2",
|
|
translation_key="electricity_delivered_tariff_2",
|
|
obis_reference=obis_references.ELECTRICITY_DELIVERED_TARIFF_2,
|
|
dsmr_versions={"2.2", "4", "5", "5B", "5L"},
|
|
device_class=SensorDeviceClass.ENERGY,
|
|
state_class=SensorStateClass.TOTAL_INCREASING,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="instantaneous_active_power_l1_positive",
|
|
translation_key="instantaneous_active_power_l1_positive",
|
|
obis_reference=obis_references.INSTANTANEOUS_ACTIVE_POWER_L1_POSITIVE,
|
|
device_class=SensorDeviceClass.POWER,
|
|
entity_registry_enabled_default=False,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="instantaneous_active_power_l2_positive",
|
|
translation_key="instantaneous_active_power_l2_positive",
|
|
obis_reference=obis_references.INSTANTANEOUS_ACTIVE_POWER_L2_POSITIVE,
|
|
device_class=SensorDeviceClass.POWER,
|
|
entity_registry_enabled_default=False,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="instantaneous_active_power_l3_positive",
|
|
translation_key="instantaneous_active_power_l3_positive",
|
|
obis_reference=obis_references.INSTANTANEOUS_ACTIVE_POWER_L3_POSITIVE,
|
|
device_class=SensorDeviceClass.POWER,
|
|
entity_registry_enabled_default=False,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="instantaneous_active_power_l1_negative",
|
|
translation_key="instantaneous_active_power_l1_negative",
|
|
obis_reference=obis_references.INSTANTANEOUS_ACTIVE_POWER_L1_NEGATIVE,
|
|
device_class=SensorDeviceClass.POWER,
|
|
entity_registry_enabled_default=False,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="instantaneous_active_power_l2_negative",
|
|
translation_key="instantaneous_active_power_l2_negative",
|
|
obis_reference=obis_references.INSTANTANEOUS_ACTIVE_POWER_L2_NEGATIVE,
|
|
device_class=SensorDeviceClass.POWER,
|
|
entity_registry_enabled_default=False,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="instantaneous_active_power_l3_negative",
|
|
translation_key="instantaneous_active_power_l3_negative",
|
|
obis_reference=obis_references.INSTANTANEOUS_ACTIVE_POWER_L3_NEGATIVE,
|
|
device_class=SensorDeviceClass.POWER,
|
|
entity_registry_enabled_default=False,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="short_power_failure_count",
|
|
translation_key="short_power_failure_count",
|
|
obis_reference=obis_references.SHORT_POWER_FAILURE_COUNT,
|
|
dsmr_versions={"2.2", "4", "5", "5L"},
|
|
entity_registry_enabled_default=False,
|
|
icon="mdi:flash-off",
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="long_power_failure_count",
|
|
translation_key="long_power_failure_count",
|
|
obis_reference=obis_references.LONG_POWER_FAILURE_COUNT,
|
|
dsmr_versions={"2.2", "4", "5", "5L"},
|
|
entity_registry_enabled_default=False,
|
|
icon="mdi:flash-off",
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="voltage_sag_l1_count",
|
|
translation_key="voltage_sag_l1_count",
|
|
obis_reference=obis_references.VOLTAGE_SAG_L1_COUNT,
|
|
dsmr_versions={"2.2", "4", "5", "5L"},
|
|
entity_registry_enabled_default=False,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="voltage_sag_l2_count",
|
|
translation_key="voltage_sag_l2_count",
|
|
obis_reference=obis_references.VOLTAGE_SAG_L2_COUNT,
|
|
dsmr_versions={"2.2", "4", "5", "5L"},
|
|
entity_registry_enabled_default=False,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="voltage_sag_l3_count",
|
|
translation_key="voltage_sag_l3_count",
|
|
obis_reference=obis_references.VOLTAGE_SAG_L3_COUNT,
|
|
dsmr_versions={"2.2", "4", "5", "5L"},
|
|
entity_registry_enabled_default=False,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="voltage_swell_l1_count",
|
|
translation_key="voltage_swell_l1_count",
|
|
obis_reference=obis_references.VOLTAGE_SWELL_L1_COUNT,
|
|
dsmr_versions={"2.2", "4", "5", "5L"},
|
|
entity_registry_enabled_default=False,
|
|
icon="mdi:pulse",
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="voltage_swell_l2_count",
|
|
translation_key="voltage_swell_l2_count",
|
|
obis_reference=obis_references.VOLTAGE_SWELL_L2_COUNT,
|
|
dsmr_versions={"2.2", "4", "5", "5L"},
|
|
entity_registry_enabled_default=False,
|
|
icon="mdi:pulse",
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="voltage_swell_l3_count",
|
|
translation_key="voltage_swell_l3_count",
|
|
obis_reference=obis_references.VOLTAGE_SWELL_L3_COUNT,
|
|
dsmr_versions={"2.2", "4", "5", "5L"},
|
|
entity_registry_enabled_default=False,
|
|
icon="mdi:pulse",
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="instantaneous_voltage_l1",
|
|
translation_key="instantaneous_voltage_l1",
|
|
obis_reference=obis_references.INSTANTANEOUS_VOLTAGE_L1,
|
|
device_class=SensorDeviceClass.VOLTAGE,
|
|
entity_registry_enabled_default=False,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="instantaneous_voltage_l2",
|
|
translation_key="instantaneous_voltage_l2",
|
|
obis_reference=obis_references.INSTANTANEOUS_VOLTAGE_L2,
|
|
device_class=SensorDeviceClass.VOLTAGE,
|
|
entity_registry_enabled_default=False,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="instantaneous_voltage_l3",
|
|
translation_key="instantaneous_voltage_l3",
|
|
obis_reference=obis_references.INSTANTANEOUS_VOLTAGE_L3,
|
|
device_class=SensorDeviceClass.VOLTAGE,
|
|
entity_registry_enabled_default=False,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="instantaneous_current_l1",
|
|
translation_key="instantaneous_current_l1",
|
|
obis_reference=obis_references.INSTANTANEOUS_CURRENT_L1,
|
|
device_class=SensorDeviceClass.CURRENT,
|
|
entity_registry_enabled_default=False,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="instantaneous_current_l2",
|
|
translation_key="instantaneous_current_l2",
|
|
obis_reference=obis_references.INSTANTANEOUS_CURRENT_L2,
|
|
device_class=SensorDeviceClass.CURRENT,
|
|
entity_registry_enabled_default=False,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="instantaneous_current_l3",
|
|
translation_key="instantaneous_current_l3",
|
|
obis_reference=obis_references.INSTANTANEOUS_CURRENT_L3,
|
|
device_class=SensorDeviceClass.CURRENT,
|
|
entity_registry_enabled_default=False,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="belgium_max_power_per_phase",
|
|
translation_key="max_power_per_phase",
|
|
obis_reference=obis_references.BELGIUM_MAX_POWER_PER_PHASE,
|
|
dsmr_versions={"5B"},
|
|
device_class=SensorDeviceClass.POWER,
|
|
entity_registry_enabled_default=False,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="belgium_max_current_per_phase",
|
|
translation_key="max_current_per_phase",
|
|
obis_reference=obis_references.BELGIUM_MAX_CURRENT_PER_PHASE,
|
|
dsmr_versions={"5B"},
|
|
device_class=SensorDeviceClass.CURRENT,
|
|
entity_registry_enabled_default=False,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
entity_category=EntityCategory.DIAGNOSTIC,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="electricity_imported_total",
|
|
translation_key="electricity_imported_total",
|
|
obis_reference=obis_references.ELECTRICITY_IMPORTED_TOTAL,
|
|
dsmr_versions={"5L", "5S", "Q3D"},
|
|
device_class=SensorDeviceClass.ENERGY,
|
|
state_class=SensorStateClass.TOTAL_INCREASING,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="electricity_exported_total",
|
|
translation_key="electricity_exported_total",
|
|
obis_reference=obis_references.ELECTRICITY_EXPORTED_TOTAL,
|
|
dsmr_versions={"5L", "5S", "Q3D"},
|
|
device_class=SensorDeviceClass.ENERGY,
|
|
state_class=SensorStateClass.TOTAL_INCREASING,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="belgium_current_average_demand",
|
|
translation_key="current_average_demand",
|
|
obis_reference=obis_references.BELGIUM_CURRENT_AVERAGE_DEMAND,
|
|
dsmr_versions={"5B"},
|
|
device_class=SensorDeviceClass.POWER,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="belgium_maximum_demand_current_month",
|
|
translation_key="maximum_demand_current_month",
|
|
obis_reference=obis_references.BELGIUM_MAXIMUM_DEMAND_MONTH,
|
|
dsmr_versions={"5B"},
|
|
device_class=SensorDeviceClass.POWER,
|
|
state_class=SensorStateClass.MEASUREMENT,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="hourly_gas_meter_reading",
|
|
translation_key="gas_meter_reading",
|
|
obis_reference=obis_references.HOURLY_GAS_METER_READING,
|
|
dsmr_versions={"4", "5", "5L"},
|
|
is_gas=True,
|
|
device_class=SensorDeviceClass.GAS,
|
|
state_class=SensorStateClass.TOTAL_INCREASING,
|
|
),
|
|
DSMRSensorEntityDescription(
|
|
key="gas_meter_reading",
|
|
translation_key="gas_meter_reading",
|
|
obis_reference=obis_references.GAS_METER_READING,
|
|
dsmr_versions={"2.2"},
|
|
is_gas=True,
|
|
device_class=SensorDeviceClass.GAS,
|
|
state_class=SensorStateClass.TOTAL_INCREASING,
|
|
),
|
|
)
|
|
|
|
|
|
def create_mbus_entity(
|
|
mbus: int, mtype: int, telegram: dict[str, DSMRObject]
|
|
) -> DSMRSensorEntityDescription | None:
|
|
"""Create a new MBUS Entity."""
|
|
if (
|
|
mtype == 3
|
|
and (
|
|
obis_reference := getattr(
|
|
obis_references, f"BELGIUM_MBUS{mbus}_METER_READING2"
|
|
)
|
|
)
|
|
in telegram
|
|
):
|
|
return DSMRSensorEntityDescription(
|
|
key=f"mbus{mbus}_gas_reading",
|
|
translation_key="gas_meter_reading",
|
|
obis_reference=obis_reference,
|
|
is_gas=True,
|
|
device_class=SensorDeviceClass.GAS,
|
|
state_class=SensorStateClass.TOTAL_INCREASING,
|
|
)
|
|
if (
|
|
mtype == 7
|
|
and (
|
|
obis_reference := getattr(
|
|
obis_references, f"BELGIUM_MBUS{mbus}_METER_READING1"
|
|
)
|
|
)
|
|
in telegram
|
|
):
|
|
return DSMRSensorEntityDescription(
|
|
key=f"mbus{mbus}_water_reading",
|
|
translation_key="water_meter_reading",
|
|
obis_reference=obis_reference,
|
|
is_water=True,
|
|
device_class=SensorDeviceClass.WATER,
|
|
state_class=SensorStateClass.TOTAL_INCREASING,
|
|
)
|
|
return None
|
|
|
|
|
|
def device_class_and_uom(
|
|
telegram: dict[str, DSMRObject],
|
|
entity_description: DSMRSensorEntityDescription,
|
|
) -> tuple[SensorDeviceClass | None, str | None]:
|
|
"""Get native unit of measurement from telegram,."""
|
|
dsmr_object = telegram[entity_description.obis_reference]
|
|
uom: str | None = getattr(dsmr_object, "unit") or None
|
|
with suppress(ValueError):
|
|
if entity_description.device_class == SensorDeviceClass.GAS and (
|
|
enery_uom := UnitOfEnergy(str(uom))
|
|
):
|
|
return (SensorDeviceClass.ENERGY, enery_uom)
|
|
if uom in UNIT_CONVERSION:
|
|
return (entity_description.device_class, UNIT_CONVERSION[uom])
|
|
return (entity_description.device_class, uom)
|
|
|
|
|
|
def rename_old_gas_to_mbus(
|
|
hass: HomeAssistant, entry: ConfigEntry, mbus_device_id: str
|
|
) -> None:
|
|
"""Rename old gas sensor to mbus variant."""
|
|
dev_reg = dr.async_get(hass)
|
|
device_entry_v1 = dev_reg.async_get_device(identifiers={(DOMAIN, entry.entry_id)})
|
|
if device_entry_v1 is not None:
|
|
device_id = device_entry_v1.id
|
|
|
|
ent_reg = er.async_get(hass)
|
|
entries = er.async_entries_for_device(ent_reg, device_id)
|
|
|
|
for entity in entries:
|
|
if entity.unique_id.endswith("belgium_5min_gas_meter_reading"):
|
|
try:
|
|
ent_reg.async_update_entity(
|
|
entity.entity_id,
|
|
new_unique_id=mbus_device_id,
|
|
device_id=mbus_device_id,
|
|
)
|
|
except ValueError:
|
|
LOGGER.debug(
|
|
"Skip migration of %s because it already exists",
|
|
entity.entity_id,
|
|
)
|
|
else:
|
|
LOGGER.debug(
|
|
"Migrated entity %s from unique id %s to %s",
|
|
entity.entity_id,
|
|
entity.unique_id,
|
|
mbus_device_id,
|
|
)
|
|
# Cleanup old device
|
|
dev_entities = er.async_entries_for_device(
|
|
ent_reg, device_id, include_disabled_entities=True
|
|
)
|
|
if not dev_entities:
|
|
dev_reg.async_remove_device(device_id)
|
|
|
|
|
|
def create_mbus_entities(
|
|
hass: HomeAssistant, telegram: dict[str, DSMRObject], entry: ConfigEntry
|
|
) -> list[DSMREntity]:
|
|
"""Create MBUS Entities."""
|
|
entities = []
|
|
for idx in range(1, 5):
|
|
if (
|
|
device_type := getattr(obis_references, f"BELGIUM_MBUS{idx}_DEVICE_TYPE")
|
|
) not in telegram:
|
|
continue
|
|
if (type_ := int(telegram[device_type].value)) not in (3, 7):
|
|
continue
|
|
if (
|
|
identifier := getattr(
|
|
obis_references,
|
|
f"BELGIUM_MBUS{idx}_EQUIPMENT_IDENTIFIER",
|
|
)
|
|
) in telegram:
|
|
serial_ = telegram[identifier].value
|
|
rename_old_gas_to_mbus(hass, entry, serial_)
|
|
else:
|
|
serial_ = ""
|
|
if description := create_mbus_entity(idx, type_, telegram):
|
|
entities.append(
|
|
DSMREntity(
|
|
description,
|
|
entry,
|
|
telegram,
|
|
*device_class_and_uom(telegram, description), # type: ignore[arg-type]
|
|
serial_,
|
|
idx,
|
|
)
|
|
)
|
|
return entities
|
|
|
|
|
|
async def async_setup_entry(
|
|
hass: HomeAssistant, entry: ConfigEntry, async_add_entities: AddEntitiesCallback
|
|
) -> None:
|
|
"""Set up the DSMR sensor."""
|
|
dsmr_version = entry.data[CONF_DSMR_VERSION]
|
|
entities: list[DSMREntity] = []
|
|
initialized: bool = False
|
|
add_entities_handler: Callable[..., None] | None
|
|
|
|
@callback
|
|
def init_async_add_entities(telegram: dict[str, DSMRObject]) -> None:
|
|
"""Add the sensor entities after the first telegram was received."""
|
|
nonlocal add_entities_handler
|
|
assert add_entities_handler is not None
|
|
add_entities_handler()
|
|
add_entities_handler = None
|
|
|
|
if dsmr_version == "5B":
|
|
mbus_entities = create_mbus_entities(hass, telegram, entry)
|
|
for mbus_entity in mbus_entities:
|
|
entities.append(mbus_entity)
|
|
|
|
entities.extend(
|
|
[
|
|
DSMREntity(
|
|
description,
|
|
entry,
|
|
telegram,
|
|
*device_class_and_uom(telegram, description), # type: ignore[arg-type]
|
|
)
|
|
for description in SENSORS
|
|
if (
|
|
description.dsmr_versions is None
|
|
or dsmr_version in description.dsmr_versions
|
|
)
|
|
and (not description.is_gas or CONF_SERIAL_ID_GAS in entry.data)
|
|
and description.obis_reference in telegram
|
|
]
|
|
)
|
|
async_add_entities(entities)
|
|
|
|
add_entities_handler = async_dispatcher_connect(
|
|
hass, EVENT_FIRST_TELEGRAM.format(entry.entry_id), init_async_add_entities
|
|
)
|
|
min_time_between_updates = timedelta(
|
|
seconds=entry.options.get(CONF_TIME_BETWEEN_UPDATE, DEFAULT_TIME_BETWEEN_UPDATE)
|
|
)
|
|
|
|
@Throttle(min_time_between_updates)
|
|
def update_entities_telegram(telegram: dict[str, DSMRObject] | None) -> None:
|
|
"""Update entities with latest telegram and trigger state update."""
|
|
nonlocal initialized
|
|
# Make all device entities aware of new telegram
|
|
for entity in entities:
|
|
entity.update_data(telegram)
|
|
|
|
if not initialized and telegram:
|
|
initialized = True
|
|
async_dispatcher_send(
|
|
hass, EVENT_FIRST_TELEGRAM.format(entry.entry_id), telegram
|
|
)
|
|
|
|
# Creates an asyncio.Protocol factory for reading DSMR telegrams from
|
|
# serial and calls update_entities_telegram to update entities on arrival
|
|
protocol = entry.data.get(CONF_PROTOCOL, DSMR_PROTOCOL)
|
|
if CONF_HOST in entry.data:
|
|
if protocol == DSMR_PROTOCOL:
|
|
create_reader = create_tcp_dsmr_reader
|
|
else:
|
|
create_reader = create_rfxtrx_tcp_dsmr_reader
|
|
reader_factory = partial(
|
|
create_reader,
|
|
entry.data[CONF_HOST],
|
|
entry.data[CONF_PORT],
|
|
dsmr_version,
|
|
update_entities_telegram,
|
|
loop=hass.loop,
|
|
keep_alive_interval=60,
|
|
)
|
|
else:
|
|
if protocol == DSMR_PROTOCOL:
|
|
create_reader = create_dsmr_reader
|
|
else:
|
|
create_reader = create_rfxtrx_dsmr_reader
|
|
reader_factory = partial(
|
|
create_reader,
|
|
entry.data[CONF_PORT],
|
|
dsmr_version,
|
|
update_entities_telegram,
|
|
loop=hass.loop,
|
|
)
|
|
|
|
async def connect_and_reconnect() -> None:
|
|
"""Connect to DSMR and keep reconnecting until Home Assistant stops."""
|
|
stop_listener = None
|
|
transport = None
|
|
protocol = None
|
|
|
|
while hass.state is CoreState.not_running or hass.is_running:
|
|
# Start DSMR asyncio.Protocol reader
|
|
|
|
# Reflect connected state in devices state by setting an
|
|
# empty telegram resulting in `unknown` states
|
|
update_entities_telegram({})
|
|
|
|
try:
|
|
transport, protocol = await hass.loop.create_task(reader_factory())
|
|
|
|
if transport:
|
|
# Register listener to close transport on HA shutdown
|
|
@callback
|
|
def close_transport(_event: Event) -> None:
|
|
"""Close the transport on HA shutdown."""
|
|
if not transport: # noqa: B023
|
|
return
|
|
transport.close() # noqa: B023
|
|
|
|
stop_listener = hass.bus.async_listen_once(
|
|
EVENT_HOMEASSISTANT_STOP, close_transport
|
|
)
|
|
|
|
# Wait for reader to close
|
|
await protocol.wait_closed()
|
|
|
|
# Unexpected disconnect
|
|
if hass.state is CoreState.not_running or hass.is_running:
|
|
stop_listener()
|
|
|
|
transport = None
|
|
protocol = None
|
|
|
|
# Reflect disconnect state in devices state by setting an
|
|
# None telegram resulting in `unavailable` states
|
|
update_entities_telegram(None)
|
|
|
|
# throttle reconnect attempts
|
|
await asyncio.sleep(DEFAULT_RECONNECT_INTERVAL)
|
|
|
|
except (serial.SerialException, OSError):
|
|
# Log any error while establishing connection and drop to retry
|
|
# connection wait
|
|
LOGGER.exception("Error connecting to DSMR")
|
|
transport = None
|
|
protocol = None
|
|
|
|
# Reflect disconnect state in devices state by setting an
|
|
# None telegram resulting in `unavailable` states
|
|
update_entities_telegram(None)
|
|
|
|
# throttle reconnect attempts
|
|
await asyncio.sleep(DEFAULT_RECONNECT_INTERVAL)
|
|
except CancelledError:
|
|
# Reflect disconnect state in devices state by setting an
|
|
# None telegram resulting in `unavailable` states
|
|
update_entities_telegram(None)
|
|
|
|
if stop_listener and (
|
|
hass.state is CoreState.not_running or hass.is_running
|
|
):
|
|
stop_listener()
|
|
|
|
if transport:
|
|
transport.close()
|
|
|
|
if protocol:
|
|
await protocol.wait_closed()
|
|
|
|
return
|
|
|
|
# Can't be hass.async_add_job because job runs forever
|
|
task = asyncio.create_task(connect_and_reconnect())
|
|
|
|
@callback
|
|
async def _async_stop(_: Event) -> None:
|
|
if add_entities_handler is not None:
|
|
add_entities_handler()
|
|
task.cancel()
|
|
|
|
# Make sure task is cancelled on shutdown (or tests complete)
|
|
entry.async_on_unload(
|
|
hass.bus.async_listen_once(EVENT_HOMEASSISTANT_STOP, _async_stop)
|
|
)
|
|
|
|
# Save the task to be able to cancel it when unloading
|
|
hass.data[DOMAIN][entry.entry_id][DATA_TASK] = task
|
|
|
|
|
|
class DSMREntity(SensorEntity):
|
|
"""Entity reading values from DSMR telegram."""
|
|
|
|
entity_description: DSMRSensorEntityDescription
|
|
_attr_has_entity_name = True
|
|
_attr_should_poll = False
|
|
|
|
def __init__(
|
|
self,
|
|
entity_description: DSMRSensorEntityDescription,
|
|
entry: ConfigEntry,
|
|
telegram: dict[str, DSMRObject],
|
|
device_class: SensorDeviceClass,
|
|
native_unit_of_measurement: str | None,
|
|
serial_id: str = "",
|
|
mbus_id: int = 0,
|
|
) -> None:
|
|
"""Initialize entity."""
|
|
self.entity_description = entity_description
|
|
self._attr_device_class = device_class
|
|
self._attr_native_unit_of_measurement = native_unit_of_measurement
|
|
self._entry = entry
|
|
self.telegram: dict[str, DSMRObject] | None = telegram
|
|
|
|
device_serial = entry.data[CONF_SERIAL_ID]
|
|
device_name = DEVICE_NAME_ELECTRICITY
|
|
if entity_description.is_gas:
|
|
if serial_id:
|
|
device_serial = serial_id
|
|
else:
|
|
device_serial = entry.data[CONF_SERIAL_ID_GAS]
|
|
device_name = DEVICE_NAME_GAS
|
|
if entity_description.is_water:
|
|
if serial_id:
|
|
device_serial = serial_id
|
|
device_name = DEVICE_NAME_WATER
|
|
if device_serial is None:
|
|
device_serial = entry.entry_id
|
|
|
|
self._attr_device_info = DeviceInfo(
|
|
identifiers={(DOMAIN, device_serial)},
|
|
name=device_name,
|
|
)
|
|
if mbus_id != 0:
|
|
if serial_id:
|
|
self._attr_unique_id = f"{device_serial}"
|
|
else:
|
|
self._attr_unique_id = f"{device_serial}_{mbus_id}"
|
|
else:
|
|
self._attr_unique_id = f"{device_serial}_{entity_description.key}"
|
|
|
|
@callback
|
|
def update_data(self, telegram: dict[str, DSMRObject] | None) -> None:
|
|
"""Update data."""
|
|
self.telegram = telegram
|
|
if self.hass and (
|
|
telegram is None or self.entity_description.obis_reference in telegram
|
|
):
|
|
self.async_write_ha_state()
|
|
|
|
def get_dsmr_object_attr(self, attribute: str) -> str | None:
|
|
"""Read attribute from last received telegram for this DSMR object."""
|
|
# Make sure telegram contains an object for this entities obis
|
|
if (
|
|
self.telegram is None
|
|
or self.entity_description.obis_reference not in self.telegram
|
|
):
|
|
return None
|
|
|
|
# Get the attribute value if the object has it
|
|
dsmr_object = self.telegram[self.entity_description.obis_reference]
|
|
attr: str | None = getattr(dsmr_object, attribute)
|
|
return attr
|
|
|
|
@property
|
|
def available(self) -> bool:
|
|
"""Entity is only available if there is a telegram."""
|
|
return self.telegram is not None
|
|
|
|
@property
|
|
def native_value(self) -> StateType:
|
|
"""Return the state of sensor, if available, translate if needed."""
|
|
value: StateType
|
|
if (value := self.get_dsmr_object_attr("value")) is None:
|
|
return None
|
|
|
|
if (
|
|
self.entity_description.obis_reference
|
|
== obis_references.ELECTRICITY_ACTIVE_TARIFF
|
|
):
|
|
return self.translate_tariff(value, self._entry.data[CONF_DSMR_VERSION])
|
|
|
|
with suppress(TypeError):
|
|
value = round(float(value), DEFAULT_PRECISION)
|
|
|
|
# Make sure we do not return a zero value for an energy sensor
|
|
if not value and self.state_class == SensorStateClass.TOTAL_INCREASING:
|
|
return None
|
|
|
|
return value
|
|
|
|
@staticmethod
|
|
def translate_tariff(value: str, dsmr_version: str) -> str | None:
|
|
"""Convert 2/1 to normal/low depending on DSMR version."""
|
|
# DSMR V5B: Note: In Belgium values are swapped:
|
|
# Rate code 2 is used for low rate and rate code 1 is used for normal rate.
|
|
if dsmr_version == "5B":
|
|
if value == "0001":
|
|
value = "0002"
|
|
elif value == "0002":
|
|
value = "0001"
|
|
# DSMR V2.2: Note: Rate code 1 is used for low rate and rate code 2 is
|
|
# used for normal rate.
|
|
if value == "0002":
|
|
return "normal"
|
|
if value == "0001":
|
|
return "low"
|
|
|
|
return None
|