@ -11,32 +11,31 @@ A climate entity controls temperature, humidity, or fans, such as A/C systems an
|
||||
Properties should always only return information from memory and not do I/O (like network requests). Implement `update()` or `async_update()` to fetch data.
|
||||
:::
|
||||
|
||||
| Name | Type | Default | Description |
|
||||
| ----------------------- | ------ | ------------------------------------ | ------------------------------------------------------------------------------------------------------------ |
|
||||
| temperature_unit | string | `NotImplementedError` | The unit of temperature measurement for the system (`TEMP_CELSIUS` or `TEMP_FAHRENHEIT`). |
|
||||
| precision | float | Based on `temperature_unit` | The precision of the temperature in the system. Defaults to tenths for TEMP_CELSIUS, whole number otherwise. |
|
||||
| current_temperature | float | None | The current temperature. |
|
||||
| current_humidity | int | None | The current humidity. |
|
||||
| target_temperature | float | None | The temperature currently set to be reached. |
|
||||
| target_temperature_high | float | None | The upper bound target temperature |
|
||||
| target_temperature_low | float | None | The lower bound target temperature |
|
||||
| target_temperature_step | float | None | The supported step size a target temperature can be increased/decreased |
|
||||
| target_humidity | float | None | The target humidity the device is trying to reach. Requires `SUPPORT_TARGET_HUMIDITY`. |
|
||||
| max_temp | float | `DEFAULT_MAX_TEMP` (value == 35) | Returns the maximum temperature. |
|
||||
| min_temp | float | `DEFAULT_MIN_TEMP` (value == 7) | Returns the minimum temperature. |
|
||||
| max_humidity | int | `DEFAULT_MAX_HUMIDITY` (value == 99) | Returns the maximum humidity. Requires `SUPPORT_TARGET_HUMIDITY`. |
|
||||
| min_humidity | int | `DEFAULT_MIN_HUMIDITY` (value == 30) | Returns the minimum humidity. Requires `SUPPORT_TARGET_HUMIDITY`. |
|
||||
| hvac_mode | HVACMode | `NotImplementedError()` | The current operation (e.g. heat, cool, idle). Used to determine `state`. |
|
||||
| hvac_action | string | None | The current HVAC action (heating, cooling) |
|
||||
| hvac_modes | list | `NotImplementedError()` | List of available operation modes. See below. |
|
||||
| preset_mode | string | `NotImplementedError()` | The current active preset. Requires `SUPPORT_PRESET_MODE`. |
|
||||
| preset_modes | list | `NotImplementedError()` | The available presets. Requires `SUPPORT_PRESET_MODE`. |
|
||||
| fan_mode | string | `NotImplementedError()` | Returns the current fan mode. Requires `SUPPORT_FAN_MODE`. |
|
||||
| fan_modes | list | `NotImplementedError()` | Returns the list of available fan modes. Requires `SUPPORT_FAN_MODE`. |
|
||||
| swing_mode | string | `NotImplementedError()` | Returns the swing setting. Requires `SUPPORT_SWING_MODE`. |
|
||||
| swing_modes | list | `NotImplementedError()` | Returns the list of available swing modes. Requires `SUPPORT_SWING_MODE`. |
|
||||
| is_aux_heat | bool | None | Returns True if an auxiliary heater is on. Requires `SUPPORT_AUX_HEAT`. |
|
||||
| supported_features | int | `NotImplementedError()` | Bitmap of supported features. See below. |
|
||||
| Name | Type | Default | Description |
|
||||
| ----------------------- | ----------------------------------- | ------------------------------------ | -------------------------------------------------------------------------- |
|
||||
| current_humidity | <code>int | None</code> | `None` | The current humidity. |
|
||||
| current_temperature | <code>float | None</code> | `None` | The current temperature. |
|
||||
| fan_mode | <code>str | None</code> | **Required by SUPPORT_FAN_MODE** | The current fan mode. |
|
||||
| fan_modes | <code>list[str] | None</code> | **Required by SUPPORT_FAN_MODE** | The list of available fan modes. |
|
||||
| hvac_action | <code>HVACAction | None</code> | `None` | The current HVAC action (heating, cooling) |
|
||||
| hvac_mode | <code>HVACMode | None</code> | **Required** | The current operation (e.g. heat, cool, idle). Used to determine `state`. |
|
||||
| hvac_modes | <code>list[HVACMode]</code> | **Required** | List of available operation modes. See below. |
|
||||
| is_aux_heat | <code>int | None</code> | **Required by SUPPORT_AUX_HEAT** | True if an auxiliary heater is on. |
|
||||
| max_humidity | `int` | `DEFAULT_MAX_HUMIDITY` (value == 99) | The maximum humidity. |
|
||||
| max_temp | `float` | `DEFAULT_MAX_TEMP` (value == 35 °C) | The maximum temperature in `temperature_unit`. |
|
||||
| min_humidity | `int` | `DEFAULT_MIN_HUMIDITY` (value == 30) | The minimum humidity. |
|
||||
| min_temp | `float` | `DEFAULT_MIN_TEMP` (value == 7 °C) | The minimum temperature in `temperature_unit`. |
|
||||
| precision | `float` | According to `temperature_unit` | The precision of the temperature in the system. Defaults to tenths for TEMP_CELSIUS, whole number otherwise. |
|
||||
| preset_mode | <code>str | None</code> | **Required by SUPPORT_PRESET_MODE** | The current active preset. |
|
||||
| preset_modes | <code>list[str] | None</code> | **Required by SUPPORT_PRESET_MODE** | The available presets. |
|
||||
| swing_mode | <code>str | None</code> | **Required by SUPPORT_SWING_MODE** | The swing setting. |
|
||||
| swing_modes | <code>list[str] | None</code> | **Required by SUPPORT_SWING_MODE** | Returns the list of available swing modes. |
|
||||
| target_humidity | <code>int | None</code> | `None` | The target humidity the device is trying to reach. |
|
||||
| target_temperature | <code>float | None</code> | `None` | The temperature currently set to be reached. |
|
||||
| target_temperature_high | <code>float | None</code> | **Required by TARGET_TEMPERATURE_RANGE** | The upper bound target temperature |
|
||||
| target_temperature_low | <code>float | None</code> | **Required by TARGET_TEMPERATURE_RANGE** | The lower bound target temperature |
|
||||
| target_temperature_step | <code>float | None</code> | `None` | The supported step size a target temperature can be increased or decreased |
|
||||
| temperature_unit | <code>str</code> | **Required** | The unit of temperature measurement for the system (`TEMP_CELSIUS` or `TEMP_FAHRENHEIT`). |
|
||||
|
||||
### HVAC modes
|
||||
|
||||
|