Add target temp range to water heater
This commit is contained in:
parent
8de9ba5404
commit
e86c6f96cb
@ -0,0 +1,33 @@
|
|||||||
|
---
|
||||||
|
author: G Johansson
|
||||||
|
authorURL: https://github.com/gjohansson-ST
|
||||||
|
authorImageURL: https://avatars.githubusercontent.com/u/62932417?v=4
|
||||||
|
authorTwitter: GJohansson
|
||||||
|
title: "Water heater now supports setting a temperature range"
|
||||||
|
---
|
||||||
|
|
||||||
|
As of Home Assistant Core 2025.8, the `WaterHeaterEntity` now also supports setting a temperature range in addition to only setting a temperature.
|
||||||
|
|
||||||
|
Entities needs to set the `TARGET_TEMPERATURE_RANGE` supported feature to enable use of setting a target temperature range.
|
||||||
|
|
||||||
|
```python
|
||||||
|
|
||||||
|
from homeassistant.components.water_heater import WaterHeaterEntity, WaterHeaterEntityFeature
|
||||||
|
|
||||||
|
class MyWaterHeater(WaterHeaterEntity):
|
||||||
|
"""My water heater."""
|
||||||
|
|
||||||
|
@property
|
||||||
|
def supported_features(self) -> WaterHeaterEntityFeature:
|
||||||
|
"""Return the supported features."""
|
||||||
|
return WaterHeaterEntityFeature.TARGET_TEMPERATURE_RANGE
|
||||||
|
|
||||||
|
async def async_set_temperature(self, **kwargs: Any) -> None:
|
||||||
|
"""Set new target temperature."""
|
||||||
|
min_temp = kwargs[ATTR_TARGET_TEMP_LOW]
|
||||||
|
max_temp = kwargs[ATTR_TARGET_TEMP_HIGH]
|
||||||
|
self.my_device.set_temperature(min_tenp, max_temp)
|
||||||
|
|
||||||
|
```
|
||||||
|
|
||||||
|
More details can be found in the [water_heater documentation](/docs/core/entity/water-heater#supported-features).
|
@ -47,18 +47,19 @@ Properties have to follow the units defined in the `temperature_unit`.
|
|||||||
Supported features are defined by using values in the `WaterHeaterEntityFeature` enum
|
Supported features are defined by using values in the `WaterHeaterEntityFeature` enum
|
||||||
and are combined using the bitwise or (`|`) operator.
|
and are combined using the bitwise or (`|`) operator.
|
||||||
|
|
||||||
| Value | Description |
|
| Value | Description |
|
||||||
| -------------------- | ------------------------- |
|
| --------------------------- | ------------------------------ |
|
||||||
| `TARGET_TEMPERATURE` | Temperature can be set |
|
| `TARGET_TEMPERATURE` | Temperature can be set |
|
||||||
| `OPERATION_MODE` | Operation mode can be set |
|
| `OPERATION_MODE` | Operation mode can be set |
|
||||||
| `AWAY_MODE` | Away mode can be set |
|
| `AWAY_MODE` | Away mode can be set |
|
||||||
| `ON_OFF` | Can be turned on or off |
|
| `ON_OFF` | Can be turned on or off |
|
||||||
|
| `TARGET_TEMPERATURE_RANGE` | Temperature range can be set |
|
||||||
|
|
||||||
## Methods
|
## Methods
|
||||||
|
|
||||||
### `set_temperature` or `async_set_temperature`
|
### `set_temperature` or `async_set_temperature`
|
||||||
|
|
||||||
Sets the temperature the water heater should heat water to.
|
Sets the temperature or temperature range the water heater should heat water to.
|
||||||
|
|
||||||
### `set_operation_mode`or `async_set_operation_mode`
|
### `set_operation_mode`or `async_set_operation_mode`
|
||||||
|
|
||||||
|