Improve water heater (#625)
* Update Water Heater Entity documentation to match WaterHeaterEntity * Remove IDE file * Add target_temperature_high/low * Fix typo * Fix another typo * Use temperature unit constants * Fix default for NotImplementedError properties * Update docs/core/entity/water-heater.md Co-authored-by: Martin Hjelmare <marhje52@gmail.com> * Update docs/core/entity/water-heater.md Co-authored-by: Martin Hjelmare <marhje52@gmail.com> * Update docs/core/entity/water-heater.md Co-authored-by: Martin Hjelmare <marhje52@gmail.com> Co-authored-by: Martin Hjelmare <marhje52@gmail.com>
This commit is contained in:
parent
063e3ffd48
commit
ff3af64cd6
@ -9,18 +9,23 @@ sidebar_label: Water Heater
|
||||
Properties should always only return information from memory and not do I/O (like network requests). Implement `update()` or `async_update()` to fetch data.
|
||||
:::
|
||||
|
||||
| Name | Type | Default | Description
|
||||
| ---- | ---- | ------- | -----------
|
||||
| min_temp | float | 110°F | The minimum temperature that can be set.
|
||||
| max_temp | float | 140°F | The maximum temperature that can be set.
|
||||
| temperature | float | none | The current temperature in °C or °F.
|
||||
| operation_mode | string | none | The current operation mode.
|
||||
| operation_list | list | none | List of possible operation modes.
|
||||
| away_mode | string | none | The current status of away mode. (on, off)
|
||||
| Name | Type | Default | Description
|
||||
| --------------------- | ----------- | --------- | -----------
|
||||
| `min_temp` | `float` | 110°F | The minimum temperature that can be set.
|
||||
| `max_temp` | `float` | 140°F | The maximum temperature that can be set.
|
||||
| `current_temperature` | `float` | `None` | The current temperature.
|
||||
| `target_temperature` | `float` | `None` | The temperature we are trying to reach.
|
||||
| `target_temperature_high` | `float` | `None` | Upper bound of the temperature we are trying to reach.
|
||||
| `target_temperature_low` | `float` | `None` | Lower bound of the temperature we are trying to reach.
|
||||
| `temperature_unit` | `str` | `NotImplementedError` | One of `TEMP_CELSIUS`, `TEMP_FAHRENHEIT`, or `TEMP_KELVIN`.
|
||||
| `current_operation` | `string` | `None` | The current operation mode.
|
||||
| `operation_list` | `List[str]` | `None` | List of possible operation modes.
|
||||
| `supported_features` | `List[str]` | `NotImplementedError` | List of supported features.
|
||||
| `is_away_mode_on` | `bool` | `None` | The current status of away mode.
|
||||
|
||||
The allowed operation modes are specified in the base component and implementations of the water_heater component cannot differ.
|
||||
The allowed operation modes are the states specified in the base component and implementations of the water_heater component cannot differ.
|
||||
|
||||
Properties have to follow the units defined in the `unit_system`.
|
||||
Properties have to follow the units defined in the `temperature_unit`.
|
||||
|
||||
## States
|
||||
|
||||
@ -34,6 +39,14 @@ Properties have to follow the units defined in the `unit_system`.
|
||||
| `STATE_GAS` | Gas only mode, uses the most energy.
|
||||
| `STATE_OFF` | The water heater is off.
|
||||
|
||||
## Supported Features
|
||||
|
||||
| Feature | Description
|
||||
| ---------------------------- | -----------
|
||||
| `SUPPORT_TARGET_TEMPERATURE` | Temperature can be set
|
||||
| `SUPPORT_OPERATION_MODE` | Operation mode can be set
|
||||
| `SUPPORT_AWAY_MODE` | Away mode can be set
|
||||
|
||||
## Methods
|
||||
|
||||
### `set_temperature` or `async_set_temperature`
|
||||
|