Create aurora_abb_powerone.markdown (#9703)

* Create aurora_abb_powerone.markdown

Supporting file to describe Aurora ABB Powerone inverter integration.

* Update summary of solar abb powerone.

* ✏️ Tweaks

* Update source/_components/aurora_abb_powerone.markdown

Co-Authored-By: Klaas Schoute <klaas_schoute@hotmail.com>

* Update source/_components/aurora_abb_powerone.markdown

Co-Authored-By: Klaas Schoute <klaas_schoute@hotmail.com>

* Corrected example configs based on comments

* Update source/_components/aurora_abb_powerone.markdown

Co-Authored-By: Franck Nijhof <frenck@frenck.nl>

* Update source/_components/aurora_abb_powerone.markdown

Co-Authored-By: Franck Nijhof <frenck@frenck.nl>

* Update source/_components/aurora_abb_powerone.markdown

Co-Authored-By: Franck Nijhof <frenck@frenck.nl>

* Added powerone logo for aurora_abb_powerone

* Reference specific logo for powerone.

* Made configuration info clearer.

* Updated config based on changes to parent PR

https://github.com/home-assistant/home-assistant.io/pull/9703

* ✏️ Tweak

* 🎉 Add name config variable
This commit is contained in:
Dave T 2019-07-10 00:01:44 +01:00 committed by Klaas Schoute
parent e04e6ca87c
commit 03e03fa226
2 changed files with 65 additions and 0 deletions

View File

@ -0,0 +1,65 @@
---
layout: page
title: "Aurora ABB Powerone PV Inverter Sensor"
description: "Instructions on how to integrate an Aurora ABB Powerone solar inverter within Home Assistant."
date: 2019-06-27 23:30
sidebar: true
comments: false
sharing: true
footer: true
logo: powerone.png
ha_category:
- Sensor
- Energy
ha_release: 0.96
ha_iot_class: Local Polling
---
This implements a direct RS485 connection to a solar inverter in the
PVI-3.0/3.6/4.2-TL-OUTD ABB series, and may work on others.
The inverter was formerly made by PowerOne who got taken over by ABB.
The TCP/IP method of communicating with inverters is supported by the
Python library, but not by this implementation in this integration.
This integration provides a single sensor which reports the live power output
in watts.
Note the PV inverter will be unresponsive to communications when in darkness,
so the value 'unknown' will be displayed during the night.
## Configuration
Add the following to your `configuration.yaml` file:
```yaml
# Example configuration.yaml entry
sensor:
- platform: aurora_abb_powerone
device: 'SERIAL_PORT'
```
{% configuration %}
device:
description: The serial port your RS485 adaptor is connected to.
required: true
type: string
address:
description: The address of the inverter - only need to set this if you have changed your inverter away from the default address of 2.
required: false
type: integer
default: 2
name:
description: Name of the sensor to use in the frontend.
required: false
default: Solar PV
type: string
{% endconfiguration %}
```yaml
# Example configuration.yaml entry for aurora_abb_powerone platform
sensor:
- platform: aurora_abb_powerone
address: 2
device: '/dev/serial/by-id/usb-FTDI_FT232R_USB_UART_A50285BI-if00-port0'
```

Binary file not shown.

After

Width:  |  Height:  |  Size: 31 KiB