@ -38,6 +38,7 @@ Configuration variables:
- **cold_tolerance** (*Optional*): Set a minimum amount of difference between the temperature read by the sensor specified in the *target_sensor* option and the target temperature that must change prior to being switched on. For example, if the target temperature is 25 and the tolerance is 0.5 the heater will start when the sensor equals or goes below 24.5.
- **hot_tolerance** (*Optional*): Set a minimum amount of difference between the temperature read by the sensor specified in the *target_sensor* option and the target temperature that must change prior to being switched off. For example, if the target temperature is 25 and the tolerance is 0.5 the heater will stop when the sensor equals or goes above 25.5.
- **keep_alive** (*Optional*): Set a keep-alive interval. If set, the switch specified in the *heater* option will be triggered every time the interval elapses. Use with heaters and A/C units that shut off if they don't receive a signal from their remote for a while.
- **initial_operation_mode** (*Optional*): Set the initial operation mode. Valid values are `off` or `auto`. Value has to be double quoted. If this parameter is not set, it is preferable to set a *keep_alive* value. This is helpful to align any discrepancies between *generic_thermostat* and *heater* state.
A full configuration example looks like the one below. `min_cycle_duration` and `keep_alive` must contain at least one of the following entries: `days:`, `hours:`, `minutes:`, `seconds:` or `milliseconds:`.
@ -57,4 +58,5 @@ climate:
seconds: 5
keep_alive:
minutes: 3
initial_operation_mode: "off"
```