mirror of
https://github.com/home-assistant/home-assistant.io.git
synced 2025-07-13 04:16:48 +00:00
update miflora component to resolve #1022
This commit is contained in:
parent
e67ff90ad3
commit
0f30f9c53e
@ -39,6 +39,9 @@ sensor
|
||||
3 (you can also use larger values) measurements. This filters out single spikes. Median: 5 will also filter double spikes.
|
||||
If you never have problems with spikes, median=1 will work fine.
|
||||
- **monitored_conditions** (*Required*): The paramaters that should be monitored.
|
||||
- **timeout** (*Optional*): Define the timeout value in seconds when polling (defaults to 10 if not defined)
|
||||
- **retries** (*Optional*): Define the number of retries when polling (defaults to 2 if not defined)
|
||||
- **cache** (*Optional*): Define cache expiration value in seconds (defaults to 1200 if not defined)
|
||||
|
||||
Note that by default the sensor is only polled once every 15 minutes. This means with the median=3 setting, it will take as least 30 minutes before the sensor will report a value after a Home Assistant restart. As the values usually change very slowly, this isn't a big problem.
|
||||
Reducing polling intervals will have a negative effect on the battery life.
|
||||
|
Loading…
x
Reference in New Issue
Block a user