Add documentation for binary sensors in the bosch alarm integration (#38345)
This commit is contained in:
parent
f6c2a7d7ee
commit
0f49eb7453
@ -3,8 +3,9 @@ title: Bosch Alarm
|
||||
description: Integrate Bosch Alarms.
|
||||
ha_category:
|
||||
- Alarm
|
||||
- Switch
|
||||
- Binary Sensor
|
||||
- Sensor
|
||||
- Switch
|
||||
ha_release: 2025.4
|
||||
ha_iot_class: Local Push
|
||||
ha_config_flow: true
|
||||
@ -14,9 +15,10 @@ ha_codeowners:
|
||||
ha_domain: bosch_alarm
|
||||
ha_platforms:
|
||||
- alarm_control_panel
|
||||
- switch
|
||||
- binary_sensor
|
||||
- diagnostics
|
||||
- sensor
|
||||
- switch
|
||||
ha_integration_type: device
|
||||
ha_quality_scale: bronze
|
||||
---
|
||||
@ -40,24 +42,31 @@ The **Bosch Alarm Panel** {% term integration %} allows you to connect your [Bos
|
||||
The following {% term entities %} are provided:
|
||||
|
||||
- [Alarm Control Panel](#alarm-control-panel)
|
||||
- [Switch](#switch)
|
||||
- [Binary Sensor](#binary-sensor)
|
||||
- [Sensor](#sensor)
|
||||
- [Switch](#switch)
|
||||
|
||||
### Alarm Control Panel
|
||||
|
||||
This integration adds an Alarm Control Panel device for each configured area, with the ability to issue arm/disarm commands.
|
||||
This entity reports state (_disarmed_, _armed_away_, etc.).
|
||||
|
||||
### Binary Sensor
|
||||
|
||||
A binary sensor is added for each point configured on your alarm.
|
||||
|
||||
Two binary sensors are added for each area to indicate whether it can be armed away or armed home.
|
||||
|
||||
### Sensor
|
||||
|
||||
A sensor is provided per area that lists how many points are currently in a faulted state.
|
||||
|
||||
### Switch
|
||||
|
||||
A switch is added for each output configured on the panel. Note that for some panels, only outputs with the type set to **remote output** can be controlled via _Mode 2_ API.
|
||||
|
||||
Three switches are added per door, which allow for locking, securing, or momentarily unlocking the door.
|
||||
|
||||
### Sensor
|
||||
|
||||
A sensor is provided per area that lists how many points are currently in a faulted state.
|
||||
|
||||
## Authentication
|
||||
|
||||
The primary means of authentication for the _Mode 2_ API is the _Automation_ passcode. It needs to be at least 10 characters long, and it is different from the _User_ code -- a shorter numeric pin used to arm/disarm the panel.
|
||||
@ -82,6 +91,34 @@ The **Bosch Alarm** {% term integration %} fetches data from the device every 30
|
||||
Newer devices and firmware revisions have the possibility to push data instead of needing to rely on {% term polling %}.
|
||||
At startup, the integration checks whether your panel supports push data updates and falls back to {% term polling %} if not.
|
||||
|
||||
## Examples
|
||||
|
||||
### Turning on lights when walking into a room
|
||||
|
||||
{% raw %}
|
||||
|
||||
```yaml
|
||||
automation:
|
||||
- alias: "Turn on light when walking into room"
|
||||
triggers:
|
||||
- platform: state
|
||||
entity_id:
|
||||
- binary_sensor.bosch_solution_3000_bedroom
|
||||
to: "on"
|
||||
actions:
|
||||
- action: light.turn_on
|
||||
target:
|
||||
entity_id: light.bedroom_light
|
||||
|
||||
|
||||
```
|
||||
|
||||
{% endraw %}
|
||||
|
||||
## Reconfiguration
|
||||
|
||||
This integration supports reconfiguration, so it is possible to change the configuration such as the IP Address after it is configured.
|
||||
|
||||
## Troubleshooting
|
||||
|
||||
### Issues with Bosch Solution 2000/3000/4000 panels
|
||||
|