diff --git a/source/_components/ebusd.markdown b/source/_components/ebusd.markdown index 7e430da574c..28c893f6a11 100644 --- a/source/_components/ebusd.markdown +++ b/source/_components/ebusd.markdown @@ -28,7 +28,7 @@ host: required: true type: string circuit: - description: The heating circuit name to monitor, e.g., 700. + description: The heating circuit name to monitor, e.g., '700', 'ehp' or 'bai'. required: true type: string port: @@ -42,7 +42,7 @@ name: required: false default: ebusd monitored_conditions: - description: List of condition to monitor. + description: List of conditions to monitor. Note that not all monitored_conditions listed here can be supported by your circuit. This integration maps limited set of keys to circuit specific ebusd values. type: list required: false keys: @@ -112,4 +112,24 @@ monitored_conditions: description: Power energy consumption from last month. PowerEnergyConsumptionThisMonth: description: Power energy consumption from the actual month. + HotWaterTemperature: + description: Hot water circuit temperature. + StorageTemperature: + description: Boiler temperature. + DesiredStorageTemperature: + description: Target boiler temperature. + OutdoorsTemperature: + description: Temperature used for weather dependent calculations. + AverageIgnitionTime: + description: Average flame ignition time (seconds). + MaximumIgnitionTime: + description: Maximum flame ignition time (seconds). + MinimumIgnitionTime: + description: Minimum flame ignition time (seconds). + ReturnTemperature: + description: Temperature returned into heater from water circuit. + DesiredFlowTemperature: + description: Target heat temperature. + FlowTemperature: + description: Out temperature. {% endconfiguration %}