Add documentation for HomeWizard Wifi Watermeter (#23328)
Co-authored-by: Franck Nijhof <frenck@frenck.nl>
This commit is contained in:
parent
bed89019b7
commit
1482a6bb88
@ -21,9 +21,16 @@ Integration for the [HomeWizard Energy](https://www.homewizard.nl/energy) platfo
|
||||
|
||||
**Supported devices**
|
||||
|
||||
- [Wifi P1 Meter](https://www.homewizard.nl/p1-meter): Depending on the connected DSMR meter: sensors for power import/export, energy consumption (single or three phases) and gas. (Model: `HWE-P1`)
|
||||
- [Wifi Energy Socket](https://www.homewizard.nl/energy-socket): Sensors for power import/export and energy consumption and switches for controlling the outlet (model: `HWE-SKT`)
|
||||
- [Wifi kWh Meter](https://www.homewizard.nl/kwh-meter): Sensors for power import/export and energy consumption. (Models: `SDM230-wifi`, `SDM630-wifi`)
|
||||
- [Wi-Fi P1 Meter](https://www.homewizard.nl/p1-meter): Depending on the connected DSMR meter: sensors for power import/export, energy consumption (single or three phases) and gas. (Model: `HWE-P1`)
|
||||
- [Wi-Fi Energy Socket](https://www.homewizard.nl/energy-socket): Sensors for power import/export and energy consumption and switches for controlling the outlet (model: `HWE-SKT`)
|
||||
- [Wi-Fi Watermeter](https://www.homewizard.com/watermeter): Sensors for active and total water usage (model: `HWE-WTR`)
|
||||
- [Wi-Fi kWh Meter](https://www.homewizard.nl/kwh-meter): Sensors for power import/export and energy consumption. (Models: `SDM230-wifi`, `SDM630-wifi`)
|
||||
|
||||
<div class='note'>
|
||||
|
||||
The Wi-Fi Watermeter can be powered via a USB-C cable and with batteries. When using batteries they only connect to Wi-Fi every couple of hours. Because of this, the API can only be used when powered via the USB-C cable. It is not possible to add use this integration when the water meter is powered by batteries.
|
||||
|
||||
</div>
|
||||
|
||||
## Enable the API
|
||||
|
||||
@ -42,19 +49,21 @@ The HomeWizard Energy API only exposes properties that are used within the HomeW
|
||||
|
||||
| Name | Unit | Availability | Description |
|
||||
| --- | --- | --- | --- |
|
||||
| Wifi SSID | | HWE-P1, SDM230-wifi, SDM630-wifi, HWE-SKT | The SSID of the connected network. |
|
||||
| Wifi Strength | % | HWE-P1, SDM230-wifi, SDM630-wifi, HWE-SKT | Percentage of the wifi connection. |
|
||||
| Total Energy Import_t1 | kWh | HWE-P1, SDM230-wifi, SDM630-wifi, HWE-SKT | Energy import reading. |
|
||||
| Wifi SSID | | HWE-P1, HWE-SKT, HWE-WTR, SDM230-wifi, SDM630-wifi | The SSID of the connected network. |
|
||||
| Wifi Strength | % | HWE-P1, HWE-SKT, HWE-WTR, SDM230-wifi, SDM630-wifi | Percentage of the Wi-Fi connection. |
|
||||
| Total Energy Import_t1 | kWh | HWE-P1, HWE-SKT, SDM230-wifi, SDM630-wifi | Energy import reading. |
|
||||
| Total Energy Import_t2 | kWh | HWE-P1 | Energy import reading for other tariff. |
|
||||
| Total Energy Export_t1 | kWh | HWE-P1, SDM230-wifi, SDM630-wifi, HWE-SKT | Energy export reading. |
|
||||
| Total Energy Export_t1 | kWh | HWE-P1, HWE-SKT, SDM230-wifi, SDM630-wifi | Energy export reading. |
|
||||
| Total Energy Export_t2 | kWh | HWE-P1 | Energy export reading for other tariff. |
|
||||
| Active Power | w | HWE-P1, SDM230-wifi, SDM630-wifi, HWE-SKT | Active power usage. |
|
||||
| Active Power_l1 | w | HWE-P1, SDM230-wifi, SDM630-wifi, HWE-SKT | Active power usage Line 1, for `SDM230-wifi` and`HWE-SKT` this value is the same as `Active Power`. |
|
||||
| Active Power | w | HWE-P1, HWE-SKT, SDM230-wifi, SDM630-wifi | Active power usage. |
|
||||
| Active Power_l1 | w | HWE-P1, HWE-SKT, SDM230-wifi, SDM630-wifi | Active power usage Line 1, for `SDM230-wifi` and`HWE-SKT` this value is the same as `Active Power`. |
|
||||
| Active Power_l2 | w | HWE-P1, SDM630-wifi | Active power usage Line 2. |
|
||||
| Active Power_l3 | w | HWE-P1, SDM630-wifi | Active power usage Line 3. |
|
||||
| Total Gas | m3 | HWE-P1 | Current gas import reading, only available when your smart meter is connected to a gas meter. |
|
||||
| DSMR Version | | HWE-P1 | The detected DSMR version. |
|
||||
| Smart Meter Model | | HWE-P1 | The detected smart meter model. |
|
||||
| Active Water Usage | liter per minute | HWE-WTR | The current usage of water. |
|
||||
| Total Water Usage | m3 | HWE-WTR | Total of water measured since installation. |
|
||||
|
||||