@ -141,6 +141,7 @@ The Wink hub, by default, can only be accessed via the cloud. This means it requ
- GoControl siren and strobe - GoControl siren and strobe
- Dome siren/chime/strobe - Dome siren/chime/strobe
- Quirky Nimbus (Legacy device) These can no longer be officialy added to your Wink account
### {% linkable_title Service `set_siren_auto_shutoff` %} ### {% linkable_title Service `set_siren_auto_shutoff` %}
@ -286,3 +287,55 @@ script:
data: data:
enabled: False enabled: False
``` ```
### {% linkable_title Service `set_nimbus_dial_state` %}
You can use the service wink/set_nimbus_dial_state to update an individual dial's value/position and it's labels
| Service data attribute | Optional | Description |
| ---------------------- | -------- | ----------- |
| `entity_id` | no | String or list of strings that point at `entity_id`s of chime/chime.
| `value` | no | A number, should be between the dials min and max value (See set_nimbus_dial_configuration below)
| `labels` | yes | A list of strings the first being the value set on the dial's face and the second being the value on the dial face when the Nimbus is pressed
Example:
```yaml
script:
set_dial_1_value:
sequence:
- service: wink.set_nimbus_dial_state
data:
entity_id: wink.nimbus_dial_1
value: 150
labels:
- "Dial 1"
- "150"
```
### {% linkable_title Service `set_nimbus_dial_configuration` %}
You can use the service wink/set_nimbus_dial_configuration to update an individual dial's configuration.
| Service data attribute | Optional | Description |
| ---------------------- | -------- | ----------- |
| `entity_id` | no | String or list of strings that point at `entity_id`s of chime/chime.
| `rotation` | yes | One of "cw" or "ccw" the direction the dial hand should rotate.
| `ticks` | yes | A positive number, the number of times the hand should move.
| `scale` | yes | One of "linear" or "log" How the dial should move in response to higher values.
| `min_value` | yes | A number, the minimum value that the dial can have.
| `max_value` | yes | A number, the maximum value that the dial can have.
| `min_position` | yes | A number generally [0-360], the minimum position for the dial's hand.
| `max_value` | yes | A number generally [0-360], the maximum position for the dial's hand.
Example:
```yaml
script:
set_dial_1_value:
sequence:
- service: wink.set_nimbus_dial_state
data:
entity_id: wink.nimbus_dial_1
rotation: 'ccw'
```