@ -50,15 +50,19 @@ Port:
|
||||
description: "The port of the APC UPS Daemon configured above."
|
||||
{% endconfiguration_basic %}
|
||||
|
||||
## Binary sensor
|
||||
## Supported functionality
|
||||
|
||||
This integration provides a binary sensor for the following information from apcupsd:
|
||||
### Entities
|
||||
|
||||
- UPS status
|
||||
The APC UPS Daemon integration provides the following entities.
|
||||
|
||||
## Sensors
|
||||
#### Binary sensors
|
||||
|
||||
This integration provides sensors for the following information from apcupsd based on their availability. Each sensor is listed here along with their corresponding resource name obtained from `apcaccess`.
|
||||
- **Online Status**
|
||||
- **Description**: Indicates whether the UPS is online, supplying power to connected devices from utility line, not the battery.
|
||||
- **Available for machines**: all
|
||||
|
||||
#### Sensors
|
||||
|
||||
{% note %}
|
||||
|
||||
@ -66,73 +70,297 @@ Some sensors are disabled by default, since they provide information that is onl
|
||||
|
||||
{% endnote %}
|
||||
|
||||
- UPS Alarm Delay (ALARMDEL)
|
||||
- UPS Ambient Temperature (AMBTEMP)
|
||||
- UPS Status Data (APC)
|
||||
- UPS Model (APCMODEL)
|
||||
- UPS Bad Batteries (BADBATTS)
|
||||
- UPS Battery Replaced (BATTDATE)
|
||||
- UPS Battery Status (BATTSTAT)
|
||||
- UPS Battery Voltage (BATTV)
|
||||
- UPS Battery (BCHARGE)
|
||||
- UPS Cable Type (CABLE)
|
||||
- UPS Total Time on Battery (CUMONBATT)
|
||||
- UPS Status Date (DATE)
|
||||
- UPS Dip Switch Settings (DIPSW)
|
||||
- UPS Low Battery Signal (DLOWBATT)
|
||||
- UPS Driver (DRIVER)
|
||||
- UPS Shutdown Delay (DSHUTD)
|
||||
- UPS Wake Delay (DWAKE)
|
||||
- UPS Date and Time (END APC)
|
||||
- UPS External Batteries (EXTBATTS)
|
||||
- UPS Firmware Version (FIRMWARE)
|
||||
- UPS Transfer High (HITRANS)
|
||||
- UPS Hostname (HOSTNAME)
|
||||
- UPS Ambient Humidity (HUMIDITY)
|
||||
- UPS Internal Temperature (ITEMP)
|
||||
- UPS Last Transfer (LASTXFER)
|
||||
- UPS Input Voltage Status (LINEFAIL)
|
||||
- UPS Line Frequency (LINEFREQ)
|
||||
- UPS Input Voltage (LINEV)
|
||||
- UPS Load (LOADPCT)
|
||||
- UPS Load Apparent Power (LOADAPNT)
|
||||
- UPS Transfer Low (LOTRANS)
|
||||
- UPS Manufacture Date (MANDATE)
|
||||
- UPS Master Update (MASTERUPD)
|
||||
- UPS Input Voltage High (MAXLINEV)
|
||||
- UPS Battery Timeout (MAXTIME)
|
||||
- UPS Battery Shutdown (MBATTCHG)
|
||||
- UPS Input Voltage Low (MINLINEV)
|
||||
- UPS Shutdown Time (MINTIMEL)
|
||||
- UPS Model (MODEL)
|
||||
- UPS Battery Nominal Voltage (NOMBATTV)
|
||||
- UPS Nominal Input Voltage (NOMINV)
|
||||
- UPS Nominal Output Voltage (NOMOUTV)
|
||||
- UPS Nominal Output Power (NOMPOWER)
|
||||
- UPS Nominal Apparent Power (NOMAPNT)
|
||||
- UPS Transfer Count (NUMXFERS)
|
||||
- UPS Output Current (OUTCURNT)
|
||||
- UPS Output Voltage (OUTPUTV)
|
||||
- UPS Register 1 Fault (REG1)
|
||||
- UPS Register 2 Fault (REG2)
|
||||
- UPS Register 3 Fault (REG3)
|
||||
- UPS Restore Requirement (RETPCT)
|
||||
- UPS Last Self Test (LASTSTEST)
|
||||
- UPS Self Test Result (SELFTEST)
|
||||
- UPS Sensitivity (SENSE)
|
||||
- UPS Serial Number (SERIALNO)
|
||||
- UPS Startup Time (STARTTIME)
|
||||
- UPS Status Flag (STATFLAG)
|
||||
- UPS Status (STATUS)
|
||||
- UPS Self Test Interval (STESTI)
|
||||
- UPS Time Left (TIMELEFT)
|
||||
- UPS Time on Battery (TONBATT)
|
||||
- UPS Mode (UPSMODE)
|
||||
- UPS Name (UPSNAME)
|
||||
- UPS Daemon Info (VERSION)
|
||||
- UPS Transfer from Battery (XOFFBAT)
|
||||
- UPS Transfer from Battery (XOFFBATT)
|
||||
- UPS Transfer to Battery (XONBATT)
|
||||
- **Alarm Delay**
|
||||
- **Description**: The delay period for the UPS alarm.
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Battery Replaced**
|
||||
- **Description**: The date that batteries were last replaced.
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Battery Voltage**
|
||||
- **Description**: Battery voltage as supplied by the UPS.
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Battery**
|
||||
- **Description**: The percentage charge on the batteries.
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Total Time on Battery**
|
||||
- **Description**: Total (cumulative) time on batteries in seconds since apcupsd startup.
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Date and Time**
|
||||
- **Description**: The time and date that the STATUS record was written.
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Transfer High**
|
||||
- **Description**: The line voltage above which the UPS will switch to batteries.
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Input Voltage**
|
||||
- **Description**: The current line voltage as returned by the UPS.
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Load**
|
||||
- **Description**: The percentage of load capacity as estimated by the UPS.
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Transfer Low**
|
||||
- **Description**: The line voltage below which the UPS will switch to batteries.
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Battery Timeout**
|
||||
- **Description**: apcupsd will shut down your system if the time on batteries exceeds this value. A value of zero disables the feature. Value is set in the configuration file (TIMEOUT).
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Battery Shutdown**
|
||||
- **Description**: If the battery charge percentage (BCHARGE) drops below this value, apcupsd will shut down your system. Value is set in the configuration file (BATTERYLEVEL).
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Shutdown Time**
|
||||
- **Description**: apcupsd will shut down your system if the remaining runtime equals or is below this point. Value is set in the configuration file (MINUTES).
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Battery Nominal Voltage**
|
||||
- **Description**: The nominal battery voltage.
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Nominal Input Voltage**
|
||||
- **Description**: The input voltage that the UPS is configured to expect.
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Nominal Output Power**
|
||||
- **Description**: The maximum power in Watts that the UPS is designed to supply.
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Transfer Count**
|
||||
- **Description**: The number of transfers to batteries since apcupsd startup.
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Last Self-test**
|
||||
- **Description**: The date and time of the last self-test performed by the UPS.
|
||||
- **Available for machines**: all
|
||||
- **Remarks**: This only becomes available when a self-test (either automatic or manual) is performed.
|
||||
|
||||
- **Self Test Result**
|
||||
- **Description**: The results of the last self test, and may have the following values:
|
||||
- OK: self test indicates good battery
|
||||
- BT: self test failed due to insufficient battery capacity
|
||||
- NG: self test failed due to overload
|
||||
- NO: No results
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Startup Time**
|
||||
- **Description**: The time/date that apcupsd was started.
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Status**
|
||||
- **Description**: The current status of the UPS (ONLINE, CHARGING, ONBATT, etc.)
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Time Left**
|
||||
- **Description**: The remaining runtime left on batteries as estimated by the UPS.
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Time on Battery**
|
||||
- **Description**: Time in seconds currently on batteries, or 0.
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Mode**
|
||||
- **Description**: The mode in which apcupsd is operating as specified in the configuration file (UPSMODE)
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Transfer from Battery**
|
||||
- **Description**: Time and date of last transfer from batteries.
|
||||
- **Available for machines**: all
|
||||
|
||||
- **Transfer to Battery**
|
||||
- **Description**: Time and date of last transfer to batteries.
|
||||
- **Available for machines**: all
|
||||
- **Remarks**: This entity only becomes available after a tranfer to battery event happens.
|
||||
|
||||
- **Battery Status**
|
||||
- **Description**: The status of the batteries.
|
||||
- **Available for machines**: Back-UPS Pro and Smart-UPS
|
||||
|
||||
- **Line Frequency**
|
||||
- **Description**: Line frequency in hertz as given by the UPS.
|
||||
- **Available for machines**: Back-UPS Pro and Smart-UPS
|
||||
|
||||
- **Load Apparent Power**
|
||||
- **Description**: An "apparent load" condition, indicating the calculated load on the UPS based on the voltage and current. This is a measure of how much power the UPS is supplying to connected devices, often reported as a percentage of its capacity.
|
||||
- **Available for machines**: Back-UPS Pro and Smart-UPS
|
||||
|
||||
- **Output Voltage**
|
||||
- **Description**: The voltage the UPS is supplying to your equipment
|
||||
- **Available for machines**: Back-UPS Pro and Smart-UPS
|
||||
|
||||
- **Bad Batteries**
|
||||
- **Description**: The number of bad battery packs.
|
||||
- **Available for machines**: Smart-UPS
|
||||
|
||||
- **Dip Switch Settings**
|
||||
- **Description**: The current dip switch settings on UPSes that have them.
|
||||
- **Available for machines**: Smart-UPS
|
||||
|
||||
- **Low Battery Signal**
|
||||
- **Description**: The remaining runtime below which the UPS sends the low battery signal. At this point apcupsd will force an immediate emergency shutdown.
|
||||
- **Available for machines**: Smart-UPS
|
||||
|
||||
- **Shutdown Delay**
|
||||
- **Description**: The grace delay that the UPS gives after receiving a power down command from apcupsd before it powers off your equipment.
|
||||
- **Available for machines**: Smart-UPS
|
||||
|
||||
- **Wake Delay**
|
||||
- **Description**: The amount of time the UPS will wait before restoring power to your equipment after a power off condition when the power is restored.
|
||||
- **Available for machines**: Smart-UPS
|
||||
|
||||
- **External Batteries**
|
||||
- **Description**: The number of external batteries as defined by the user. A correct number here helps the UPS compute the remaining runtime more accurately.
|
||||
- **Available for machines**: Smart-UPS
|
||||
|
||||
- **Internal Temperature**
|
||||
- **Description**: Internal UPS temperature as supplied by the UPS.
|
||||
- **Available for machines**: Smart-UPS
|
||||
|
||||
- **Input Voltage Status**
|
||||
- **Description**: The input line voltage status. "OK" indicates normal operation.
|
||||
- **Available for machines**: Smart-UPS
|
||||
|
||||
- **Master Update**
|
||||
- **Description**: The last time the master sent an update to the device.
|
||||
- **Available for machines**: Smart-UPS
|
||||
|
||||
- **Input Voltage High**
|
||||
- **Description**: The maximum line voltage since the UPS was started, as reported by the UPS.
|
||||
- **Available for machines**: Smart-UPS
|
||||
|
||||
- **Input Voltage Low**
|
||||
- **Description**: The minimum line voltage since the UPS was started, as returned by the UPS.
|
||||
- **Available for machines**: Smart-UPS
|
||||
|
||||
- **Nominal Output Voltage**
|
||||
- **Description**: The output voltage that the UPS will attempt to supply when on battery power.
|
||||
- **Available for machines**: Smart-UPS
|
||||
|
||||
- **Nominal Apparent Power**
|
||||
- **Description**: The rated apparent power capacity.
|
||||
- **Available for machines**: Smart-UPS
|
||||
|
||||
- **Output Current**
|
||||
- **Description**: The output current being supplied by the UPS to the connected devices
|
||||
- **Available for machines**: Smart-UPS
|
||||
|
||||
- **Restore Requirement**
|
||||
- **Description**: The percentage charge that the batteries must have after a power off condition before the UPS will restore power to your equipment.
|
||||
- **Available for machines**: Smart-UPS
|
||||
|
||||
- **Self Test Interval**
|
||||
- **Description**: The interval in hours between automatic self tests.
|
||||
- **Available for machines**: Smart-UPS
|
||||
|
||||
- **Transfer from Battery**
|
||||
- **Description**: The date and time of last transfer off battery since apcupsd startup.
|
||||
- **Available for machines**: Smart-UPS
|
||||
|
||||
- **Ambient Humidity**
|
||||
- **Description**: The humidity as measured by the UPS.
|
||||
- **Available for machines**: Smart-UPS with optional accessories (e.g., temperature/humidity sensors or SNMP network cards).
|
||||
|
||||
- **Ambient Temperature**
|
||||
- **Description**: The ambient temperature as measured by the UPS.
|
||||
- **Available for machines**: Smart-UPS with optional accessories (e.g., temperature/humidity sensors or SNMP network cards).
|
||||
|
||||
- **Status Data**
|
||||
- **Description**: Header record indicating the STATUS format revision level, the number of records that follow the APC statement, and the number of bytes that follow the record.
|
||||
- **Available for machines**: all
|
||||
- **Remarks**: Disabled by default for advanced uses.
|
||||
|
||||
- **Model**
|
||||
- **Description**: The old APC model identification code.
|
||||
- **Available for machines**: Smart-UPS
|
||||
- **Remarks**: Disabled by default for advanced uses.
|
||||
|
||||
- **Cable Type**
|
||||
- **Description**: The cable as specified in the configuration file (UPSCABLE).
|
||||
- **Available for machines**: all
|
||||
- **Remarks**: Disabled by default for advanced uses.
|
||||
|
||||
- **Status Date**
|
||||
- **Description**: The date and time that the information was last obtained from the UPS.
|
||||
- **Available for machines**: all
|
||||
- **Remarks**: Disabled by default for advanced uses.
|
||||
|
||||
- **Driver**
|
||||
- **Description**: The driver used to communicate with the UPS.
|
||||
- **Available for machines**: all
|
||||
- **Remarks**: Disabled by default for advanced uses.
|
||||
|
||||
- **Firmware Version**
|
||||
- **Description**: The firmware revision number as reported by the UPS.
|
||||
- **Available for machines**: all
|
||||
- **Remarks**: Disabled by default for advanced uses.
|
||||
|
||||
- **Hostname**
|
||||
- **Description**: The name of the machine that collected the UPS data.
|
||||
- **Available for machines**: all
|
||||
- **Remarks**: Disabled by default for advanced uses.
|
||||
|
||||
- **Last Transfer**
|
||||
- **Description**: The reason for the last transfer to batteries.
|
||||
- **Available for machines**: all
|
||||
- **Remarks**: Disabled by default for advanced uses.
|
||||
|
||||
- **Manufacture Date**
|
||||
- **Description**: The date the UPS was manufactured.
|
||||
- **Available for machines**: Smart-UPS
|
||||
- **Remarks**: Disabled by default for advanced uses.
|
||||
|
||||
- **Model**
|
||||
- **Description**: The UPS model as derived from information from the UPS.
|
||||
- **Available for machines**: all
|
||||
- **Remarks**: Disabled by default for advanced uses.
|
||||
|
||||
- **Register 1 Fault**
|
||||
- **Description**: The value from the UPS fault register 1.
|
||||
- **Available for machines**: Smart-UPS
|
||||
- **Remarks**: Disabled by default for advanced uses.
|
||||
|
||||
- **Register 2 Fault**
|
||||
- **Description**: The value from the UPS fault register 2.
|
||||
- **Available for machines**: Smart-UPS
|
||||
- **Remarks**: Disabled by default for advanced uses.
|
||||
|
||||
- **Register 3 Fault**
|
||||
- **Description**: The value from the UPS fault register 3.
|
||||
- **Available for machines**: Smart-UPS
|
||||
- **Remarks**: Disabled by default for advanced uses.
|
||||
|
||||
- **Sensitivity**
|
||||
- **Description**: The sensitivity level of the UPS to line voltage fluctuations.
|
||||
- **Available for machines**: all
|
||||
- **Remarks**: Disabled by default for advanced uses.
|
||||
|
||||
- **Serial Number**
|
||||
- **Description**: The UPS serial number.
|
||||
- **Available for machines**: all
|
||||
- **Remarks**: Disabled by default for advanced uses.
|
||||
|
||||
- **Status Flag**
|
||||
- **Description**: Status flag. English version is given by STATUS.
|
||||
- **Available for machines**: all
|
||||
- **Remarks**: Disabled by default for advanced uses.
|
||||
|
||||
- **Name**
|
||||
- **Description**: The name of the UPS as stored in the EEPROM or in the UPSNAME directive in the configuration file.
|
||||
- **Available for machines**: all
|
||||
- **Remarks**: Disabled by default for advanced uses.
|
||||
|
||||
- **Daemon Info**
|
||||
- **Description**: The apcupsd release number, build date, and platform.
|
||||
- **Available for machines**: all
|
||||
- **Remarks**: Disabled by default for advanced uses.
|
||||
|
||||
## Examples
|
||||
|
||||
|