@ -9,7 +9,7 @@ ha_iot_class: Local Polling
|
|||||||
ha_release: 0.96
|
ha_release: 0.96
|
||||||
---
|
---
|
||||||
|
|
||||||
The `fronius` sensor will poll a [Fronius](http://www.fronius.com/) solar inverter, battery system or smart meter and present the values as sensors (or attributes of sensors) in Home Assistant.
|
The `fronius` sensor polls a [Fronius](http://www.fronius.com/) solar inverter, battery system or smart meter and present the values as sensors in Home Assistant.
|
||||||
|
|
||||||
## Configuration
|
## Configuration
|
||||||
|
|
||||||
@ -33,7 +33,7 @@ monitored_conditions:
|
|||||||
required: true
|
required: true
|
||||||
type: list
|
type: list
|
||||||
keys:
|
keys:
|
||||||
type:
|
sensor_type:
|
||||||
description: "The kind of device, can be one of \"inverter\", \"storage\", \"meter\", or \"power_flow\""
|
description: "The kind of device, can be one of \"inverter\", \"storage\", \"meter\", or \"power_flow\""
|
||||||
required: true
|
required: true
|
||||||
type: string
|
type: string
|
||||||
@ -48,6 +48,44 @@ monitored_conditions:
|
|||||||
default: "\"1\" for inverters and \"0\" for other devices such as storages in compliance with Fronius Specs"
|
default: "\"1\" for inverters and \"0\" for other devices such as storages in compliance with Fronius Specs"
|
||||||
{% endconfiguration %}
|
{% endconfiguration %}
|
||||||
|
|
||||||
|
## Monitored data
|
||||||
|
|
||||||
|
Each sensor type chosen as monitored condition adds a set of sensors to Home Assistant.
|
||||||
|
|
||||||
|
- `power_flow`
|
||||||
|
|
||||||
|
Cumulative data such as the energy produced in the current day or year and overall produced energy.
|
||||||
|
Also, live values such as:
|
||||||
|
|
||||||
|
- Power fed to the grid (if positive) or taken from the grid (if negative).
|
||||||
|
- Power load as a generator (if positive) or consumer (if negative).
|
||||||
|
- Battery charging power (if positive) or discharging power (if negative) and information about backup or standby mode.
|
||||||
|
- Photovoltaic production.
|
||||||
|
- Current relative self-consumption of produced energy.
|
||||||
|
- Current relative autonomy.
|
||||||
|
|
||||||
|
- `inverter`
|
||||||
|
|
||||||
|
Cumulative data such as the energy produced in the current day or year and overall produced energy.
|
||||||
|
Also, live values about AC/DC power, current, voltage and frequency.
|
||||||
|
The data is only shown when choosing device scope.
|
||||||
|
|
||||||
|
- `meter`
|
||||||
|
|
||||||
|
Detailed information about power, current and voltage, if supported split among the phases.
|
||||||
|
The data is only shown when choosing device scope.
|
||||||
|
|
||||||
|
- `storage`
|
||||||
|
|
||||||
|
Detailed information about current, voltage, state, cycle count, capacity and more about installed batteries.
|
||||||
|
|
||||||
|
Note that some data (like photovoltaic production) is only provided by the Fronius device when non-zero.
|
||||||
|
The corresponding sensors are added to Home Assistant as entities as soon as they are available.
|
||||||
|
This means for example that when Home Assistant is started at night,
|
||||||
|
there might be no sensor providing photovoltaic related data.
|
||||||
|
This does not need to be problematic as the values will be added on sunrise,
|
||||||
|
when the Fronius devices begins providing the needed data.
|
||||||
|
|
||||||
## Examples
|
## Examples
|
||||||
|
|
||||||
When including more of the components that one Fronius device offers,
|
When including more of the components that one Fronius device offers,
|
||||||
@ -68,31 +106,3 @@ sensor:
|
|||||||
device: 0
|
device: 0
|
||||||
- sensor_type: power_flow
|
- sensor_type: power_flow
|
||||||
```
|
```
|
||||||
|
|
||||||
## Sensors configuration
|
|
||||||
|
|
||||||
To extract more detailed values from the state of each integrated sensor and to circumvent undefined values,
|
|
||||||
it is recommended to use template sensors as an interface:
|
|
||||||
|
|
||||||
{% raw %}
|
|
||||||
```yaml
|
|
||||||
- platform: template
|
|
||||||
sensors:
|
|
||||||
electricity_inverter1_power_netto:
|
|
||||||
unit_of_measurement: 'W'
|
|
||||||
value_template: >-
|
|
||||||
{% if states.sensor.fronius_1921684247_inverter_1.attributes.power_ac is defined -%}
|
|
||||||
{{ states_attr('sensor.fronius_1921684247_inverter_1', 'power_ac') | float | round(2) }}
|
|
||||||
{%- else -%}
|
|
||||||
0
|
|
||||||
{%- endif %}
|
|
||||||
electricity_autonomy:
|
|
||||||
unit_of_measurement: '%'
|
|
||||||
value_template: >-
|
|
||||||
{% if states.sensor.fronius_1921684247_power_flow.attributes.relative_autonomy is defined -%}
|
|
||||||
{{ states_attr('sensor.fronius_1921684247_power_flow', 'relative_autonomy') | float | round(2) }}
|
|
||||||
{%- else -%}
|
|
||||||
0
|
|
||||||
{%- endif %}
|
|
||||||
```
|
|
||||||
{% endraw %}
|
|
||||||
|