Fronius component documentation (#9283)

* Documentation for Fronius sensor component

* Update fronius description

* Fix templating error

* Update doc according to new implementation

* Update configuration description

* Fixes

* Update source/_components/fronius.markdown

Co-Authored-By: nielstron <n.muendler@web.de>

* Update source/_components/fronius.markdown

Co-Authored-By: nielstron <n.muendler@web.de>

* Remove last line

* Simplify example

* Escape yaml templates

* Remove "token" that cannot start any token according to deploy

* Rework description

* Fix configuration strings

* Fix configuration look

* ✏️ Tweaks

* ✏️ Tweak

* Correct documentation

* Change fronius ip to fronius url

* ✏️ Tweak

* ✏️ Use `state_attr()`
This commit is contained in:
Niels Mündler 2019-07-16 09:19:47 +02:00 committed by Franck Nijhof
parent 75aaa5341c
commit 39de364172
2 changed files with 98 additions and 0 deletions

View File

@ -0,0 +1,98 @@
---
title: "Fronius"
description: "Instructions on how to connect your Fronius Inverter to Home Assistant."
ha_category:
- Energy
- Sensor
logo: fronius.png
ha_iot_class: Local Polling
ha_release: 0.96
---
The `fronius` sensor will poll a [Fronius](http://www.fronius.com/) solar inverter, battery system or smart meter and present the values as sensors (or attributes of sensors) in Home Assistant.
## Configuration
To enable this sensor, add the following lines to your `configuration.yaml` file:
```yaml
sensor:
- platform: fronius
resource: FRONIUS_URL
monitored_conditions:
- sensor_type: inverter
```
{% configuration %}
resource:
description: "The IP address of the Fronius device"
required: true
type: string
monitored_conditions:
description: "Conditions to display in the frontend"
required: true
type: list
keys:
type:
description: "The kind of device, can be one of \"inverter\", \"storage\", \"meter\", or \"power_flow\""
required: true
type: string
scope:
description: "The device type for storage and inverter, can be either \"device\" or \"system\""
required: false
type: string
default: "device"
device:
description: "The id of the device to poll"
required: false
default: "\"1\" for inverters and \"0\" for other devices such as storages in compliance with Fronius Specs"
{% endconfiguration %}
## Examples
When including more of the components that one Fronius device offers,
a list of sensors that are to be integrated can be given like below.
```yaml
sensor:
- platform: fronius
resource: FRONIUS_IP_ADDRESS
monitored_conditions:
- sensor_type: inverter
device: 1
- sensor_type: meter
scope: system
- sensor_type: meter
device: 3
- sensor_type: storage
device: 0
- sensor_type: power_flow
```
## Sensors configuration
To extract more detailed values from the state of each integrated sensor and to circumvent undefined values,
it is recommended to use template sensors as an interface:
{% raw %}
```yaml
- platform: template
sensors:
electricity_inverter1_power_netto:
unit_of_measurement: 'W'
value_template: >-
{% if states.sensor.fronius_1921684247_inverter_1.attributes.power_ac is defined -%}
{{ states_attr('sensor.fronius_1921684247_inverter_1', 'power_ac') | float | round(2) }}
{%- else -%}
0
{%- endif %}
electricity_autonomy:
unit_of_measurement: '%'
value_template: >-
{% if states.sensor.fronius_1921684247_power_flow.attributes.relative_autonomy is defined -%}
{{ states_attr('sensor.fronius_1921684247_power_flow', 'relative_autonomy') | float | round(2) }}
{%- else -%}
0
{%- endif %}
```
{% endraw %}