@ -72,6 +72,11 @@ disarm_after_trigger:
required: false
type: boolean
default: false
arming_states:
description: Limit the supported arming states.
required: false
type: list
default: armed_away, armed_home, armed_night, armed_vacation, armed_custom_bypass
armed_custom_bypass/armed_home/armed_away/armed_night/armed_vacation/disarmed/triggered:
description: State specific settings
required: false
@ -132,6 +137,7 @@ be used for example to sound the siren for a shorter time during the night.
In the configuration example below:
- The only arming states allowed are `armed_away` and `armed_home`.
- The `disarmed` state never triggers the alarm.
- The `armed_home` state will leave no time to leave the building or disarm the alarm.
- The other states will give 30 seconds to leave the building before triggering the alarm, and 20 seconds to disarm the alarm when coming back.
@ -145,6 +151,9 @@ alarm_control_panel:
arming_time: 30
delay_time: 20
trigger_time: 4
arming_states:
- armed_away
- armed_home
disarmed:
trigger_time: 0
armed_home: