mirror of
https://github.com/home-assistant/home-assistant.io.git
synced 2025-07-09 18:36:51 +00:00
update nuheat docs for recent component changes (#4296)
This commit is contained in:
parent
4db836f80a
commit
3c43e0b45b
@ -62,24 +62,6 @@ not in auto operation mode.
|
||||
| ---------------| ----------- |
|
||||
| Integer | Target temperature
|
||||
|
||||
### {% linkable_title Attribute `target_temperature_low` %}
|
||||
|
||||
Returns the desired heating temperature set in the thermostat when in
|
||||
auto operation mode.
|
||||
|
||||
| Attribute type | Description |
|
||||
| ---------------| ----------- |
|
||||
| Integer | Target temperature
|
||||
|
||||
### {% linkable_title Attribute `target_temperature_high` %}
|
||||
|
||||
Returns the desired cooling temperature set in the thermostat when in
|
||||
auto operation mode.
|
||||
|
||||
| Attribute type | Description |
|
||||
| ---------------| ----------- |
|
||||
| Integer | Target temperature
|
||||
|
||||
### {% linkable_title Attribute `current_hold_mode` %}
|
||||
|
||||
Returns the current temperature hold, if any.
|
||||
@ -123,13 +105,13 @@ Returns the maximum supported temperature by the thermostat
|
||||
|
||||
## {% linkable_title Services %}
|
||||
|
||||
The following services are provided by the NuHeat Thermostat: `set_temperature`, `resume_program`.
|
||||
The following services are provided by the NuHeat Thermostat: `set_temperature`, `set_hold_mode`, `nuheat_resume_program`.
|
||||
|
||||
The services `fan_min_on_time`, `set_aux_heat`, `set_away_mode`, `set_hold_mode`, `set_humidity`, `set_fan_mode`, `set_operation_mode` and `set_swing_mode` offered by the [Climate component](/components/climate/) are not implemented for this thermostat.
|
||||
The services `fan_min_on_time`, `set_aux_heat`, `set_away_mode`, `set_humidity`, `set_fan_mode`, `set_operation_mode` and `set_swing_mode` offered by the [Climate component](/components/climate/) are not implemented for this thermostat.
|
||||
|
||||
### {% linkable_title Service `set_temperature` %}
|
||||
|
||||
Puts the thermostat into a temporary hold at the given temperature.
|
||||
Puts the thermostat into an indefinite hold at the given temperature.
|
||||
|
||||
| Service data attribute | Optional | Description |
|
||||
| ---------------------- | -------- | ----------- |
|
||||
@ -139,7 +121,16 @@ Puts the thermostat into a temporary hold at the given temperature.
|
||||
Only the target temperatures relevant for the current operation mode need to
|
||||
be provided.
|
||||
|
||||
### {% linkable_title Service `resume_program` %}
|
||||
### {% linkable_title Service `set_hold_mode` %}
|
||||
|
||||
Sets the thermostat's hold mode. The NuHeat thermostat supports "auto" (to run the thermostat's programmed schedule), "temperature" (to indefinitely hold the thermostat's current target temperature), or "temporary_temperature" (to hold the thermostat's current target temperature until the thermostat's next scheduled event).
|
||||
|
||||
| Service data attribute | Optional | Description |
|
||||
| ---------------------- | -------- | ----------- |
|
||||
| `entity_id` | yes | String or list of strings that point at `entity_id`'s of climate devices to control. Else targets all.
|
||||
| `hold_mode` | no | New value of hold mode.
|
||||
|
||||
### {% linkable_title Service `nuheat_resume_program` %}
|
||||
|
||||
Resumes the currently active schedule.
|
||||
|
||||
|
Loading…
x
Reference in New Issue
Block a user