diff --git a/source/_integrations/iammeter.markdown b/source/_integrations/iammeter.markdown new file mode 100644 index 00000000000..a799893f78e --- /dev/null +++ b/source/_integrations/iammeter.markdown @@ -0,0 +1,83 @@ +--- +title: "iammeter" +description: "Instructions on how to integrate IAMMETER sensor within Home Assistant." +logo: iammeter-logo.png +ha_category: + - Energy + - Sensor +ha_release: 0.107 +ha_iot_class: Local Polling +ha_domain: iammeter +--- + +`iammeter` provides real-time readings of single-phase (WEM3080, WEM3162) and three-phase (WEM3080T) meters from [IAMMETER](https://www.iammeter.com) over Wi-Fi. + +## Configuration + +To use this sensor in your installation, add the following to your `configuration.yaml` file: + +```yaml +# Example configuration.yaml entry +sensor: + - platform: iammeter + host: IP_ADDRESS_OF_HOST +``` + +{% configuration %} +host: + description: The IP address of your IAMMETER. + required: true + type: string +port: + description: port of your IAMMETER. + required: false + default: 80 + type: integer +name: + description: Name for the sensor entity. + required: false + type: string + default: IamMeter +{% endconfiguration %} + +## Sensors + +Sensors available in the library: + +### Single-phase energy meter (WEM3080/WEM3162) + +| name | Unit | Description | +|--------------------|------|:-----------------------------------------------------------------------------| +| wem3080_voltage | V | Voltage. | +| wem3080_current | A | current. | +| wem3080_power | W | active power. | +| wem3080_importenergy | kWh | Energy consumption from gird | +| wem3080_exportgrid | kWh | Energy export to grid | + +### Three-phase energy meter (WEM3080T) + +| name | Unit | Description | +|--------------------|------|:-----------------------------------------------------------------------------| +| wem3080t_voltage_a | V | A phase voltage | +| wem3080t_current_a | A | A phase current | +| wem3080t_power_a | W | A phase active power | +| wem3080t_importenergy_a | kWh | A phase import energy | +| wem3080t_exportgrid_a | kWh | A phase export energy | +| wem3080t_frequency_a | kWh | A phase frequency | +| wem3080t_pf_a | kWh | A phase power factor | +| | | | +| wem3080t_voltage_b | V | B phase voltage | +| wem3080t_current_b | A | B phase current | +| wem3080t_power_b | W | B phase active power | +| wem3080t_importenergy_b | kWh | B phase import energy | +| wem3080t_exportgrid_b | kWh | B phase export energy | +| wem3080t_frequency_b | kWh | B phase frequency | +| wem3080t_pf_b | kWh | B phase power factor | +| | | | +| wem3080t_voltage_c | V | C phase voltage | +| wem3080t_current_c | A | C phase current | +| wem3080t_power_c | W | C phase active power | +| wem3080t_importenergy_c | kWh | C phase import energy | +| wem3080t_exportgrid_c | kWh | C phase export energy | +| wem3080t_frequency_c | kWh | C phase frequency | +| wem3080t_pf_c | kWh | C phase power factor | diff --git a/source/images/supported_brands/iammeter-logo.png b/source/images/supported_brands/iammeter-logo.png new file mode 100644 index 00000000000..d178816c2e2 Binary files /dev/null and b/source/images/supported_brands/iammeter-logo.png differ