Document credentials update for Enphase Envoy (#31410)
Co-authored-by: J. Nick Koston <nick@koston.org>
This commit is contained in:
parent
b188c80266
commit
43f32aa00e
@ -60,10 +60,17 @@ For models running firmware 5 and older, use `installer` for the username. No pa
|
|||||||
The Enphase Enpower has 4 load shedding relays that can be used to control non-essential loads in your home. These have two main modes of operation:
|
The Enphase Enpower has 4 load shedding relays that can be used to control non-essential loads in your home. These have two main modes of operation:
|
||||||
|
|
||||||
### Standard
|
### Standard
|
||||||
|
|
||||||
When the mode entity is set to standard, you can simply set the state of the relay to be powered or not powered for each mode of operation: on grid, off grid, and on generator.
|
When the mode entity is set to standard, you can simply set the state of the relay to be powered or not powered for each mode of operation: on grid, off grid, and on generator.
|
||||||
|
|
||||||
### Battery level
|
### Battery level
|
||||||
|
|
||||||
When the relay mode is set to battery level, the relays will turn on and off based on the remaining battery level of your Encharge batteries. Two number entities are available to control the cutoff and restore levels for the relays. When the battery level drops below the cutoff level, the relays will turn off. When the battery level rises above the restore level, the relays will turn back on.
|
When the relay mode is set to battery level, the relays will turn on and off based on the remaining battery level of your Encharge batteries. Two number entities are available to control the cutoff and restore levels for the relays. When the battery level drops below the cutoff level, the relays will turn off. When the battery level rises above the restore level, the relays will turn back on.
|
||||||
|
|
||||||
## Polling interval
|
## Polling interval
|
||||||
The default polling interval is 60 seconds. To customize the polling interval, refer to [defining a custom polling interval](/common-tasks/general/#defining-a-custom-polling-interval). Specify the envoy device as a target of the service using the `+ choose device` button. Updating the envoy will also update the related devices like the inverters; there is no need to split them into separate entities or add all inverter devices. When using multiple Envoys, add them as targets or create separate custom polling intervals as needed.
|
|
||||||
|
The default polling interval is 60 seconds. To customize the polling interval, refer to [defining a custom polling interval](/common-tasks/general/#defining-a-custom-polling-interval). Specify one single entity from the envoy device as target of the service using the `+ choose entity` button. Updating one entity will update all entities of the Envoy and the related devices like the inverters; there is no need to specify multiple or all entities or add (all) inverter entities. When using multiple Envoys, add one entity for each envoy as targets or create separate custom polling intervals with a single entity as needed.
|
||||||
|
|
||||||
|
## Credentials update
|
||||||
|
|
||||||
|
This integration supports updating configuration by re-adding the integration and specifying the same or new IP address, username, and password. Use this method if your Enlighten credentials or the device's IP address has changed and needs to be updated.
|
||||||
|