@ -45,10 +45,16 @@ There are two generations of devices. Both generations are supported by this int
## Shelly device configuration (generation 1)
Shelly devices use the `CoIoT` protocol to communicate with integration. For Shelly firmware 1.10.0 or newer, `CoIoT` must be enabled in the device settings. Navigate to the local IP address of your Shelly device, **Internet & Security** >> **ADVANCED - DEVELOPER SETTINGS** and check the box **Enable CoIoT**.
Generation 1 devices use the `CoIoT` protocol to communicate with the integration. For Shelly firmware 1.10.0 or newer, `CoIoT` must be enabled in the device settings. Navigate to the local IP address of your Shelly device, **Internet & Security** >> **ADVANCED - DEVELOPER SETTINGS** and check the box **Enable CoIoT**.
We recommend using `unicast` for communication. To enable this, enter the local IP address of the Home Assistant server and port `5683` into the **CoIoT peer** field and push **SAVE** button. This is mandatory for Shelly Motion with firmware 1.1.0 or newer. After changing the **CoIoT peer**, the Shelly device needs to be manually restarted.
## Shelly device configuration (generation 2)
Generation 2 devices use the `RPC` protocol to communicate with the integration. Battery powered devices need manual outbound websocket configuration, Navigate to the local IP address of your Shelly device, **Networks** >> **Outbound websocket** and check the box **Enable**, under server enter the following address:
`ws://` + `Home_Assistant_local_address:Port` + `/api/shelly/ws` (for example: `ws://homeassistant.local:8123/api/shelly/ws`), click **Apply** to save the settings.
<div class="note">
Integration is communicating directly with the device; cloud connection is not needed.
</div>