mirror of
https://github.com/home-assistant/home-assistant.io.git
synced 2025-07-14 04:46:49 +00:00
Updating and correction example to avoid warnings in HA log (#13461)
This commit is contained in:
parent
bc0635cdc6
commit
503c3e71f6
@ -39,17 +39,79 @@ You can use V_TEMP to send the current temperature from the node to Home Assista
|
||||
For more information, visit the [serial API](https://www.mysensors.org/download) of MySensors.
|
||||
|
||||
## Example sketch for MySensors 2.x
|
||||
|
||||
{% raw %}
|
||||
```cpp
|
||||
/*
|
||||
* Documentation: https://www.mysensors.org
|
||||
* Support Forum: https://forum.mysensors.org
|
||||
*/
|
||||
/**
|
||||
* The MySensors Arduino library handles the wireless radio link and protocol
|
||||
* between your home built sensors/actuators and HA controller of choice.
|
||||
* The sensors forms a self healing radio network with optional repeaters. Each
|
||||
* repeater and gateway builds a routing tables in EEPROM which keeps track of the
|
||||
* network topology allowing messages to be routed to nodes.
|
||||
*
|
||||
* Created by Henrik Ekblad <henrik.ekblad@mysensors.org>
|
||||
* Copyright (C) 2013-2015 Sensnology AB
|
||||
* Full contributor list: https://github.com/mysensors/Arduino/graphs/contributors
|
||||
*
|
||||
* Documentation: http://www.mysensors.org
|
||||
* Support Forum: http://forum.mysensors.org
|
||||
*
|
||||
* This program is free software; you can redistribute it and/or
|
||||
* modify it under the terms of the GNU General Public License
|
||||
* version 2 as published by the Free Software Foundation.
|
||||
*
|
||||
*******************************
|
||||
*
|
||||
* REVISION HISTORY
|
||||
* Version 1.0 - Toni A - https://github.com/ToniA/arduino-heatpumpir
|
||||
* Version 2.1 - Author unknown - example script from the Home Assistant website : https://www.home-assistant.io/integrations/climate.mysensors
|
||||
* Version 2.2 - Eric Van Bocxlaer - based on the example script from the Home Assistant website : https://www.home-assistant.io/integrations/climate.mysensors
|
||||
* - https://community.home-assistant.io/t/mysensors-hvac-not-showing-up/22540
|
||||
* Version 2.3 - Eric Van Bocxlaer - correction states send back to home assistant, is expecting text values and not numeric values
|
||||
*
|
||||
* DESCRIPTION
|
||||
* Heatpump controller
|
||||
*/
|
||||
|
||||
#define MY_RADIO_NRF24
|
||||
#define CHILD_ID_HVAC 0
|
||||
// Enable debug prints to serial monitor
|
||||
//#define MY_DEBUG
|
||||
// Enable specific RFM69 debug prints to serial monitor
|
||||
//#define MY_DEBUG_VERBOSE_RFM69
|
||||
|
||||
#define MY_NODE_ID 3 // set the node ID manually because a MQTT gateway will not assign automatically a node Id - this must be set before the mysensors.h call
|
||||
|
||||
// Enable and select radio type attached. Replace the defines if you use other radio type hardware.
|
||||
#define MY_RADIO_RFM69
|
||||
#define MY_RFM69_FREQUENCY RFM69_868MHZ // Set your frequency here
|
||||
#define MY_IS_RFM69HW // Omit if your RFM is not "H"
|
||||
#define MY_RFM69_NEW_DRIVER // soft spi for rfm69 radio works only with new driver
|
||||
|
||||
//enable radio communication encryption
|
||||
// more information can be found on https://forum.mysensors.org/topic/10382/security-signing-messages-and-encryption-of-messages-a-guide-or-more-a-summary-of-my-tests?_=1588348189475
|
||||
//#define MY_ENCRYPTION_SIMPLE_PASSWD "your16bitpassword"
|
||||
//enable simple signing
|
||||
//#define MY_SIGNING_SIMPLE_PASSWD "your32bitpassword"
|
||||
//#define MY_SIGNING_SIMPLE_PASSWD "your16bitpassword"
|
||||
//enable simple signing and encryption
|
||||
//#define MY_SECURITY_SIMPLE_PASSWORD "your16bitpassword"
|
||||
//enable simple signing and encryption
|
||||
#define MY_SECURITY_SIMPLE_PASSWORD "your32bitpassword"
|
||||
//enable soft signing
|
||||
//#define MY_SIGNING_SOFT
|
||||
//#define MY_SIGNING_REQUEST_SIGNATURES
|
||||
//#define MY_SIGNING_SOFT_RANDOMSEED_PIN A0
|
||||
// following hex codes are dummy hex codes, replace by your hexcodes (see the link above how to generate)
|
||||
//#define MY_SIGNING_NODE_WHITELISTING {{.nodeId = 0,.serial = {0x99,0x88,0x77,0x66,0x55,0x44,0x33,0x22,0x11}},{.nodeId = 1,.serial = {0x11,0x22,0x33,0x44,0x55,0x66,0x77,0x88,0x99}}}
|
||||
|
||||
#include <MySensors.h> // sketch tested with version 2.3.2, see http://librarymanager/all#MySensors
|
||||
|
||||
#define SENSOR_NAME "Heatpump Sensor"
|
||||
#define SENSOR_VERSION "2.3"
|
||||
|
||||
#define CHILD_ID_HVAC 0 // Each radio node can report data for up to 254 different child sensors. You are free to choose the child id yourself.
|
||||
// You should avoid using child-id 255 because it is used for things like sending in battery level and other (protocol internal) node specific information.
|
||||
|
||||
#define IR_PIN 3 // Arduino pin tied to the IR led using Arduino PWM
|
||||
|
||||
#include <MySensors.h>
|
||||
|
||||
// Uncomment your heatpump model
|
||||
//#include <FujitsuHeatpumpIR.h>
|
||||
@ -58,11 +120,11 @@ For more information, visit the [serial API](https://www.mysensors.org/download)
|
||||
//#include <CarrierHeatpumpIR.h>
|
||||
//#include <MideaHeatpumpIR.h>
|
||||
//#include <MitsubishiHeatpumpIR.h>
|
||||
//#include <SamsungHeatpumpIR.h>
|
||||
//#include <SamsungHeatpumpIR.h> // sketch tested with version 1.0.15, see http://librarymanager#HeatpumpIR by Toni Arte
|
||||
//#include <SharpHeatpumpIR.h>
|
||||
//#include <DaikinHeatpumpIR.h>
|
||||
|
||||
//Some global variables to hold the states
|
||||
//Some global variables to hold the numeric states sent to the airco unit
|
||||
int POWER_STATE;
|
||||
int TEMP_STATE;
|
||||
int FAN_STATE;
|
||||
@ -70,11 +132,15 @@ int MODE_STATE;
|
||||
int VDIR_STATE;
|
||||
int HDIR_STATE;
|
||||
|
||||
IRSenderPWM irSender(3); // IR led on Arduino digital pin 3, using Arduino PWM
|
||||
//Some global variables to hold the text states sent to the home assistant controller
|
||||
String FAN_STATE_TXT; // possible values ("Min", "Normal", "Max", "Auto")
|
||||
String MODE_STATE_TXT; // possible values ("Off", "HeatOn", "CoolOn", or "AutoChangeOver")
|
||||
|
||||
//Change to your Heatpump
|
||||
HeatpumpIR *heatpumpIR = new PanasonicNKEHeatpumpIR();
|
||||
|
||||
IRSenderPWM irSender(IR_PIN);
|
||||
|
||||
//Change to your own Heatpump
|
||||
//HeatpumpIR *heatpumpIR = new SamsungAQV12MSANHeatpumpIR();
|
||||
/*
|
||||
new PanasonicDKEHeatpumpIR()
|
||||
new PanasonicJKEHeatpumpIR()
|
||||
@ -84,7 +150,9 @@ new MideaHeatpumpIR()
|
||||
new FujitsuHeatpumpIR()
|
||||
new MitsubishiFDHeatpumpIR()
|
||||
new MitsubishiFEHeatpumpIR()
|
||||
new SamsungHeatpumpIR()
|
||||
new SamsungAQVHeatpumpIR()
|
||||
new SamsungFJMHeatpumpIR()
|
||||
// new SamsungHeatpumpIR() is a protected generic method, cannot be created directly
|
||||
new SharpHeatpumpIR()
|
||||
new DaikinHeatpumpIR()
|
||||
*/
|
||||
@ -96,7 +164,10 @@ MyMessage msgHVACFlowState(CHILD_ID_HVAC, V_HVAC_FLOW_STATE);
|
||||
bool initialValueSent = false;
|
||||
|
||||
void presentation() {
|
||||
sendSketchInfo("Heatpump", "2.1");
|
||||
// Send the sketch version information to the gateway and Controller
|
||||
sendSketchInfo(SENSOR_NAME, SENSOR_VERSION);
|
||||
|
||||
// Register all sensors to gw (they will be created as child devices) by their ID and S_TYPE
|
||||
present(CHILD_ID_HVAC, S_HVAC, "Thermostat");
|
||||
}
|
||||
|
||||
@ -106,9 +177,13 @@ void setup() {
|
||||
void loop() {
|
||||
// put your main code here, to run repeatedly:
|
||||
if (!initialValueSent) {
|
||||
send(msgHVACSetPointC.set(20));
|
||||
send(msgHVACSpeed.set("Auto"));
|
||||
send(msgHVACFlowState.set("Off"));
|
||||
FAN_STATE_TXT = "Auto"; // default fan start state
|
||||
TEMP_STATE = 20; // default start temperature
|
||||
MODE_STATE_TXT = "Off"; // default mode state
|
||||
|
||||
send(msgHVACSetPointC.set(TEMP_STATE));
|
||||
send(msgHVACSpeed.set(FAN_STATE_TXT.c_str()));
|
||||
send(msgHVACFlowState.set(MODE_STATE_TXT.c_str()));
|
||||
|
||||
initialValueSent = true;
|
||||
}
|
||||
@ -136,6 +211,7 @@ void receive(const MyMessage &message) {
|
||||
else if(recvData.equalsIgnoreCase("min")) FAN_STATE = 1;
|
||||
else if(recvData.equalsIgnoreCase("normal")) FAN_STATE = 2;
|
||||
else if(recvData.equalsIgnoreCase("max")) FAN_STATE = 3;
|
||||
FAN_STATE_TXT = recvData;
|
||||
break;
|
||||
|
||||
case V_HVAC_SETPOINT_COOL:
|
||||
@ -161,6 +237,7 @@ void receive(const MyMessage &message) {
|
||||
else if (recvData.equalsIgnoreCase("off")){
|
||||
POWER_STATE = 0;
|
||||
}
|
||||
MODE_STATE_TXT = recvData;
|
||||
break;
|
||||
}
|
||||
sendHeatpumpCommand();
|
||||
@ -168,12 +245,19 @@ void receive(const MyMessage &message) {
|
||||
}
|
||||
|
||||
void sendNewStateToGateway() {
|
||||
Serial.println("Status update send to HA:");
|
||||
Serial.println("*************************");
|
||||
Serial.println("Mode = " + MODE_STATE_TXT + "(" + (String)MODE_STATE + ")");
|
||||
Serial.println("Fan = " + FAN_STATE_TXT + "(" + (String)FAN_STATE + ")");
|
||||
Serial.println("Temp = " + (String)TEMP_STATE);
|
||||
send(msgHVACFlowState.set(MODE_STATE_TXT.c_str()));
|
||||
send(msgHVACSpeed.set(FAN_STATE_TXT.c_str()));
|
||||
send(msgHVACSetPointC.set(TEMP_STATE));
|
||||
send(msgHVACSpeed.set(FAN_STATE));
|
||||
send(msgHVACFlowState.set(MODE_STATE));
|
||||
}
|
||||
|
||||
void sendHeatpumpCommand() {
|
||||
Serial.println("Heatpump commands send to airco:");
|
||||
Serial.println("********************************");
|
||||
Serial.println("Power = " + (String)POWER_STATE);
|
||||
Serial.println("Mode = " + (String)MODE_STATE);
|
||||
Serial.println("Fan = " + (String)FAN_STATE);
|
||||
@ -182,6 +266,7 @@ void sendHeatpumpCommand() {
|
||||
heatpumpIR->send(irSender, POWER_STATE, MODE_STATE, FAN_STATE, TEMP_STATE, VDIR_AUTO, HDIR_AUTO);
|
||||
}
|
||||
```
|
||||