@ -682,6 +682,40 @@ climates:
value 1 is written."
required: false
type: integer
swing_mode_register:
description: "Configuration of the register for swing mode"
required: false
type: map
keys:
address:
description: "Address of swing mode register. (int to call write_register, list of 1 int to call write_registers). - Reading done through holding register"
required: true
type: [integer, list]
values:
description: "Mapping between the register values and swing modes"
required: true
type: map
keys:
swing_mode_state_on:
description: "Value corresponding to swing mode on."
required: false
type: integer
swing_mode_state_off:
description: "Value corresponding to swing mode off."
required: false
type: integer
swing_mode_state_horizontal:
description: "Value corresponding to swing mode horizontal."
required: false
type: integer
swing_mode_state_vertical:
description: "Value corresponding to swing mode vertical."
required: false
type: integer
swing_mode_state_both:
description: "Value corresponding to Swing mode both."
required: false
type: integer
input_type:
description: Modbus register type for current temperature.
required: false