@ -1,7 +1,6 @@
|
||||
---
|
||||
title: apcupsd
|
||||
description: Instructions on how to integrate apcupsd status with Home Assistant.
|
||||
logo: apcupsd.png
|
||||
ha_category:
|
||||
- Binary Sensor
|
||||
- Sensor
|
||||
@ -9,18 +8,21 @@ ha_category:
|
||||
ha_release: 0.13
|
||||
ha_iot_class: Local Polling
|
||||
ha_domain: apcupsd
|
||||
ha_config_flow: true
|
||||
ha_codeowners:
|
||||
- '@yuxincs'
|
||||
ha_platforms:
|
||||
- binary_sensor
|
||||
- sensor
|
||||
ha_integration_type: integration
|
||||
---
|
||||
|
||||
[Apcupsd](http://www.apcupsd.org/) status information can be integrated into Home Assistant when the Network Information Server (NIS) [is configured](http://www.apcupsd.org/manual/manual.html#nis-server-client-configuration-using-the-net-driver) on the APC device.
|
||||
[apcupsd](http://www.apcupsd.org/) status information can be integrated into Home Assistant when the Network Information Server (NIS) [is configured](http://www.apcupsd.org/manual/manual.html#nis-server-client-configuration-using-the-net-driver) on the APC device.
|
||||
|
||||
There is currently support for the following device types within Home Assistant:
|
||||
|
||||
- [Binary Sensor](#binary-sensor)
|
||||
- [Sensor](#sensor)
|
||||
- [Sensor](#sensors)
|
||||
|
||||
## Home Assistant add-on installation
|
||||
|
||||
@ -28,136 +30,95 @@ Install this [unofficial add-on](https://github.com/korylprince/hassio-apcupsd/)
|
||||
|
||||
After installation, follow the instructions on the GitHub page to configure the plugin. Then continue to follow the integration configurations below.
|
||||
|
||||
## Configuration
|
||||
|
||||
To enable this sensor, add the following lines to your `configuration.yaml`:
|
||||
|
||||
```yaml
|
||||
# Example configuration.yaml entry
|
||||
apcupsd:
|
||||
```
|
||||
|
||||
{% configuration %}
|
||||
host:
|
||||
description: The hostname/IP address on which the apcupsd NIS is being served.
|
||||
required: false
|
||||
type: string
|
||||
default: localhost
|
||||
port:
|
||||
description: The port on which the apcupsd NIS is listening.
|
||||
required: false
|
||||
type: integer
|
||||
default: 3551
|
||||
{% endconfiguration %}
|
||||
{% include integrations/config_flow.md %}
|
||||
|
||||
<div class='note'>
|
||||
|
||||
If you get `ConnectionRefusedError: Connection refused` errors in the Home Assistant logs, ensure the [Apcupsd](http://www.apcupsd.org/) configuration directives used by its Network Information Server is set to permit connections from all addresses [NISIP 0.0.0.0](http://www.apcupsd.org/manual/manual.html#configuration-directives-used-by-the-network-information-server), else non-local addresses will not connect.
|
||||
If you get `ConnectionRefusedError: Connection refused` errors in the Home Assistant logs, ensure the [apcupsd](http://www.apcupsd.org/) configuration directives used by its Network Information Server is set to permit connections from all addresses [NISIP 0.0.0.0](http://www.apcupsd.org/manual/manual.html#configuration-directives-used-by-the-network-information-server), else non-local addresses will not connect.
|
||||
|
||||
</div>
|
||||
|
||||
</div>
|
||||
|
||||
## Binary sensor
|
||||
|
||||
In addition to the [Apcupsd Sensor](#sensor) devices, you may also create a device which is simply "on" when the UPS status is online and "off" at all other times.
|
||||
This integration provides a binary sensor for the following information from apcupsd:
|
||||
|
||||
### Configuration
|
||||
- UPS status
|
||||
|
||||
To enable this sensor, you first have to set up apcupsd integration (above), and add the following lines to your `configuration.yaml` file:
|
||||
## Sensors
|
||||
|
||||
```yaml
|
||||
# Example configuration.yaml entry
|
||||
binary_sensor:
|
||||
- platform: apcupsd
|
||||
```
|
||||
This integration provides sensors for the following information from apcupsd based on their availability. Each sensor is listed here along with their corresponding resource name obtained from `apcaccess`.
|
||||
|
||||
{% configuration %}
|
||||
name:
|
||||
description: Name to use in the frontend.
|
||||
required: false
|
||||
type: string
|
||||
default: UPS Online Status
|
||||
{% endconfiguration %}
|
||||
<div class='note'>
|
||||
|
||||
## Sensor
|
||||
Some sensors are disabled by default, since they provide information that is only useful for advanced users. You can manually enable them in **{% my entities title="Settings -> Devices & Services -> Entities" %}** -> the sensor entity you want to enable -> Advanced settings -> Enabled.
|
||||
|
||||
The `apcupsd` sensor platform allows you to monitor a UPS (battery backup) by using data from the [apcaccess](https://linux.die.net/man/8/apcaccess) command.
|
||||
</div>
|
||||
|
||||
### Configuration
|
||||
- UPS Alarm Delay (ALARMDEL)
|
||||
- UPS Ambient Temperature (AMBTEMP)
|
||||
- UPS Status Data (APC)
|
||||
- UPS Model (APCMODEL)
|
||||
- UPS Bad Batteries (BADBATTS)
|
||||
- UPS Battery Replaced (BATTDATE)
|
||||
- UPS Battery Status (BATTSTAT)
|
||||
- UPS Battery Voltage (BATTV)
|
||||
- UPS Battery (BCHARGE)
|
||||
- UPS Cable Type (CABLE)
|
||||
- UPS Total Time on Battery (CUMONBATT)
|
||||
- UPS Status Date (DATE)
|
||||
- UPS Dip Switch Settings (DIPSW)
|
||||
- UPS Low Battery Signal (DLOWBATT)
|
||||
- UPS Driver (DRIVER)
|
||||
- UPS Shutdown Delay (DSHUTD)
|
||||
- UPS Wake Delay (DWAKE)
|
||||
- UPS Date and Time (END APC)
|
||||
- UPS External Batteries (EXTBATTS)
|
||||
- UPS Firmware Version (FIRMWARE)
|
||||
- UPS Transfer High (HITRANS)
|
||||
- UPS Hostname (HOSTNAME)
|
||||
- UPS Ambient Humidity (HUMIDITY)
|
||||
- UPS Internal Temperature (ITEMP)
|
||||
- UPS Last Transfer (LASTXFER)
|
||||
- UPS Input Voltage Status (LINEFAIL)
|
||||
- UPS Line Frequency (LINEFREQ)
|
||||
- UPS Input Voltage (LINEV)
|
||||
- UPS Load (LOADPCT)
|
||||
- UPS Load Apparent Power (LOADAPNT)
|
||||
- UPS Transfer Low (LOTRANS)
|
||||
- UPS Manufacture Date (MANDATE)
|
||||
- UPS Master Update (MASTERUPD)
|
||||
- UPS Input Voltage High (MAXLINEV)
|
||||
- UPS Battery Timeout (MAXTIME)
|
||||
- UPS Battery Shutdown (MBATTCHG)
|
||||
- UPS Input Voltage Low (MINLINEV)
|
||||
- UPS Shutdown Time (MINTIMEL)
|
||||
- UPS Model (MODEL)
|
||||
- UPS Battery Nominal Voltage (NOMBATTV)
|
||||
- UPS Nominal Input Voltage (NOMINV)
|
||||
- UPS Nominal Output Voltage (NOMOUTV)
|
||||
- UPS Nominal Output Power (NOMPOWER)
|
||||
- UPS Nominal Apparent Power (NOMAPNT)
|
||||
- UPS Transfer Count (NUMXFERS)
|
||||
- UPS Output Current (OUTCURNT)
|
||||
- UPS Output Voltage (OUTPUTV)
|
||||
- UPS Register 1 Fault (REG1)
|
||||
- UPS Register 2 Fault (REG2)
|
||||
- UPS Register 3 Fault (REG3)
|
||||
- UPS Restore Requirement (RETPCT)
|
||||
- UPS Last Self Test (SELFTEST)
|
||||
- UPS Sensitivity (SENSE)
|
||||
- UPS Serial Number (SERIALNO)
|
||||
- UPS Startup Time (STARTTIME)
|
||||
- UPS Status Flag (STATFLAG)
|
||||
- UPS Status (STATUS)
|
||||
- UPS Self Test Interval (STESTI)
|
||||
- UPS Time Left (TIMELEFT)
|
||||
- UPS Time on Battery (TONBATT)
|
||||
- UPS Mode (UPSMODE)
|
||||
- UPS Name (UPSNAME)
|
||||
- UPS Daemon Info (VERSION)
|
||||
- UPS Transfer from Battery (XOFFBAT)
|
||||
- UPS Transfer from Battery (XOFFBATT)
|
||||
- UPS Transfer to Battery (XONBATT)
|
||||
|
||||
To use this sensor platform, you first have to set up apcupsd integration (above), and add the following to your `configuration.yaml` file:
|
||||
|
||||
```yaml
|
||||
# Example configuration.yaml entry
|
||||
sensor:
|
||||
- platform: apcupsd
|
||||
resources:
|
||||
- bcharge
|
||||
- linev
|
||||
```
|
||||
|
||||
{% configuration %}
|
||||
resources:
|
||||
description: Contains all entries to display.
|
||||
required: true
|
||||
type: list
|
||||
{% endconfiguration %}
|
||||
|
||||
### Example
|
||||
|
||||
Given the following output from `apcaccess`:
|
||||
|
||||
```yaml
|
||||
APC : 001,051,1149
|
||||
DATE : 2016-02-09 17:13:31 +0000
|
||||
HOSTNAME : localhost
|
||||
VERSION : 3.14.12 (29 March 2014) redhat
|
||||
UPSNAME : netrack
|
||||
CABLE : Custom Cable Smart
|
||||
DRIVER : APC Smart UPS (any)
|
||||
UPSMODE : Stand Alone
|
||||
STARTTIME: 2016-02-09 16:06:47 +0000
|
||||
MODEL : SMART-UPS 1400
|
||||
STATUS : TRIM ONLINE
|
||||
LINEV : 247.0 Volts
|
||||
LOADPCT : 13.0 Percent
|
||||
BCHARGE : 100.0 Percent
|
||||
TIMELEFT : 104.0 Minutes
|
||||
MBATTCHG : 5 Percent
|
||||
MINTIMEL : 3 Minutes
|
||||
MAXTIME : 0 Seconds
|
||||
MAXLINEV : 249.6 Volts
|
||||
MINLINEV : 244.4 Volts
|
||||
OUTPUTV : 218.4 Volts
|
||||
[...]
|
||||
```
|
||||
|
||||
Use the values from the left hand column (lower case required).
|
||||
|
||||
Full Example Configuration:
|
||||
|
||||
```yaml
|
||||
sensor:
|
||||
- platform: apcupsd
|
||||
resources:
|
||||
- apc
|
||||
- date
|
||||
- hostname
|
||||
- version
|
||||
- upsname
|
||||
- cable
|
||||
- driver
|
||||
- upsmode
|
||||
- starttime
|
||||
- model
|
||||
- status
|
||||
- linev
|
||||
- loadpct
|
||||
- bcharge
|
||||
- timeleft
|
||||
- mbattchg
|
||||
- mintimel
|
||||
- maxtime
|
||||
- maxlinev
|
||||
- minlinev
|
||||
- outputv
|
||||
```
|
||||
|
Loading…