@ -408,6 +408,18 @@ modbus:
|
||||
target_temp_register: 2782
|
||||
temp_step: 1
|
||||
temperature_unit: C
|
||||
- name: "Bedroom Air Condition"
|
||||
address: 10
|
||||
target_temp_register: 10
|
||||
hvac_mode_register:
|
||||
address: 11
|
||||
values:
|
||||
auto: 0
|
||||
cool: 1
|
||||
heat: 2
|
||||
fan_only: 3
|
||||
dry: 4
|
||||
hvac_onoff_register: 11
|
||||
```
|
||||
|
||||
{% configuration %}
|
||||
@ -454,6 +466,56 @@ climates:
|
||||
required: false
|
||||
type: string
|
||||
default: C
|
||||
hvac_mode_register:
|
||||
description: Definition of a register holding and controlling an HVAC mode
|
||||
required: false
|
||||
type: [map]
|
||||
keys:
|
||||
address:
|
||||
description: The address of the HVAC mode register.
|
||||
required: true
|
||||
type: integer
|
||||
values:
|
||||
description: A mapping between the register values and HVAC modes
|
||||
required: true
|
||||
type: [map]
|
||||
keys:
|
||||
"off":
|
||||
description: The register value corresponding to HVAC Off mode.
|
||||
required: false
|
||||
type: integer
|
||||
heat:
|
||||
description: The register value corresponding to HVAC Heat mode.
|
||||
required: false
|
||||
type: integer
|
||||
cool:
|
||||
description: The register value corresponding to HVAC Cool mode.
|
||||
required: false
|
||||
type: integer
|
||||
auto:
|
||||
description: The register value corresponding to HVAC Auto mode.
|
||||
required: false
|
||||
type: integer
|
||||
dry:
|
||||
description: The register value corresponding to HVAC Dry mode.
|
||||
required: false
|
||||
type: integer
|
||||
fan_only:
|
||||
description: The register value corresponding to HVAC Fan only mode.
|
||||
required: false
|
||||
type: integer
|
||||
heat_cool:
|
||||
description: The register value corresponding to HVAC Heat/Cool mode.
|
||||
required: false
|
||||
type: integer
|
||||
hvac_onoff_register:
|
||||
description: Address of a register holding and controlling the On/Off state of the climate device.
|
||||
When zero is read from this register, the HVAC state is set to Off, otherwise the `hvac_mode_register`
|
||||
dictates the state of the HVAC. If no such register is defined, it defaults to Auto.
|
||||
When the HVAC mode is set to Off, the value 0 is written to the register, otherwise the
|
||||
value 1 is written.
|
||||
required: false
|
||||
type: integer
|
||||
unique_id:
|
||||
description: An ID that uniquely identifies this sensor. If two sensors have the same unique ID, Home Assistant will raise an exception.
|
||||
required: false
|
||||
@ -466,6 +528,12 @@ climates:
|
||||
| ------- | ----------- |
|
||||
| set_temperature | Set Temperature. Requires `value` to be passed in, which is the desired target temperature. `value` should be in the same type as `data_type` |
|
||||
|
||||
### Service `modbus.set_hvac_mode`
|
||||
|
||||
| Service | Description |
|
||||
| ------- | ----------- |
|
||||
| set_hvac_mode | Set HVAC mode. Requires `value` to be passed in, which is the desired mode. `value` should be a valid HVAC mode. A mapping between the desired state and the value to be written to the HVAC mode register must exist. Calling this service will also set the On/Off register to an appropriate value, if such a register is defined. |
|
||||
|
||||
## Configuring platform cover
|
||||
|
||||
The `modbus` cover platform allows you to control covers (such as blinds, a roller shutter, or a garage door).
|
||||
|