@ -48,21 +48,14 @@ device_password:
type: string
{% endconfiguration %}
## Switch State Attributes
## Sensors
| Attribute | Type | Description | Example |
| ------------------ | ------- | ------------------------------------------------------ | ----------------- |
| `friendly_name` | string | Defaults to the device's configured name. | "Switcher Boiler" |
| `auto_off_set` | string | The auto shutdown time limit configured on the device. | "01:30:00" |
| `remaining_time` | string | Time remaining to shutdown (auto or timer). | "01:29:41" |
| `electric_current` | float | The electric current in amps. | 12.5 |
| `current_power_w` | integer | The current power used in watts. | 2756 |
<div class='note warning'>
Please note, the following attributes are not eligible when the device is off and therefore will not appear as state attributes: `remaining_time`, `electric_current`, `current_power_w`.
</div>
| Sensor Name | Description | Example |
| ------------------- | ------------------------------------------------------ | ----------------- |
| `Auto Shutdown` | The auto shutdown time limit configured on the device | 01:30:00 |
| `Remaining Time` | Time remaining to shutdown (auto or timer) | 01:29:41 |
| `Electric Current` | The electric current in amps | 12.5 A |
| `Power Consumption` | The power consumption in watts | 2756 W |
## Services
@ -74,8 +67,8 @@ Meaning the device will turn itself off when reaching the auto-off configuration
| Service Field | Mandatory | Description | Example |
| ------------- | --------- | -------------------------------------------------------------------------------------- | -------------------------- |
| `entity_id` | Yes | Name of the entity id associated with the integration, used for permission validation. | switch.switcher_kis_boiler |
| `auto_off` | Yes | Time period string containing hours and minutes. | "02:30" |
| `entity_id` | Yes | Name of the entity id associated with the integration, used for permission validation | switch.switcher_kis_boiler |
| `auto_off` | Yes | Time period string containing hours and minutes | "02:30" |
### Service: `switcher_kis.turn_on_with_timer`
@ -85,5 +78,5 @@ Meaning the device will turn itself off when timer ends.
Note: This does not affect the auto off timer.
| Service Field | Mandatory | Description | Example |
| ------------- | --------- | -------------------------------------------------------------------------------------- | -------------------------- |
| `entity_id` | Yes | Name of the entity id associated with the integration, used for permission validation. | switch.switcher_kis_boiler |
| `entity_id` | Yes | Name of the entity id associated with the integration, used for permission validation | switch.switcher_kis_boiler |
| `timer_minutes` | Yes | Integer containing timer minutes (valid range 1 to 150) | 90 |