remove away mode documentation, since that functionality was requested to be removed
This commit is contained in:
parent
2c10e3392e
commit
5b8aabf383
@ -23,12 +23,10 @@ The NuHeat Thermostat supports the following key concepts.
|
||||
|
||||
The _target temperature_ is the temperature that the device attempts to achieve. The target temperature is either determined by the schedule programmed into the thermostat (_auto mode_) or may be overridden. When the target temperature is set by home assistant, the thermostat will hold this temperature until the schedule is resumed.
|
||||
|
||||
When in _away mode_ the temperature is permanently overridden to the minimum temperature supported by the thermostat.
|
||||
|
||||
|
||||
## {% linkable_title Attributes %}
|
||||
|
||||
The following attributes are provided by the NuHeat thermostat: `name`, `temperature_unit`, `current_temperature`, `target_temperature`, `target_temperature_low`, `target_temperature_high`, `current_hold_mode`, `current_operation`, `operation_list`, `is_away_mode_on`, `min_temp`, `max_temp`
|
||||
The following attributes are provided by the NuHeat thermostat: `name`, `temperature_unit`, `current_temperature`, `target_temperature`, `current_hold_mode`, `current_operation`, `operation_list`, `min_temp`, `max_temp`
|
||||
|
||||
|
||||
### {% linkable_title Attribute `name` %}
|
||||
@ -88,7 +86,7 @@ Returns the current temperature hold, if any.
|
||||
|
||||
| Attribute type | Description |
|
||||
| ---------------| ----------- |
|
||||
| String | 'temperature', 'temporary_temperature', 'away', 'auto', etc.
|
||||
| String | 'temperature', 'temporary_temperature', 'auto', etc.
|
||||
|
||||
### {% linkable_title Attribute `current_operation` %}
|
||||
|
||||
@ -106,14 +104,6 @@ Returns the list of available operation modes.
|
||||
| ---------------| ----------- |
|
||||
| List of String | Available operation modes
|
||||
|
||||
### {% linkable_title Attribute `is_away_mode_on` %}
|
||||
|
||||
Returns whether the thermostat is in away mode.
|
||||
|
||||
| Attribute type | Description |
|
||||
| ---------------| ----------- |
|
||||
| Boolean | True, False
|
||||
|
||||
### {% linkable_title Attribute `min_temp` %}
|
||||
|
||||
Returns the minimum supported temperature by the thermostat
|
||||
@ -133,18 +123,9 @@ Returns the maximum supported temperature by the thermostat
|
||||
|
||||
## {% linkable_title Services %}
|
||||
|
||||
The following services are provided by the NuHeat Thermostat: `set_away_mode`, `set_temperature`, `resume_program`.
|
||||
The following services are provided by the NuHeat Thermostat: `set_temperature`, `resume_program`.
|
||||
|
||||
The services `fan_min_on_time`, `set_aux_heat`, `set_hold_mode`, `set_humidity`, `set_fan_mode`, `set_operation_mode` and `set_swing_mode` offered by the [Climate component](/components/climate/) are not implemented for this thermostat.
|
||||
|
||||
### {% linkable_title Service `set_away_mode` %}
|
||||
|
||||
Turns the away mode on or off for the thermostat.
|
||||
|
||||
| Service data attribute | Optional | Description |
|
||||
| ---------------------- | -------- | ----------- |
|
||||
| `entity_id` | yes | String or list of strings that point at `entity_id`'s of climate devices to control. Else targets all.
|
||||
| `away_mode` | no | 'on' or 'off'
|
||||
The services `fan_min_on_time`, `set_aux_heat`, `set_away_mode`, `set_hold_mode`, `set_humidity`, `set_fan_mode`, `set_operation_mode` and `set_swing_mode` offered by the [Climate component](/components/climate/) are not implemented for this thermostat.
|
||||
|
||||
### {% linkable_title Service `set_temperature` %}
|
||||
|
||||
@ -153,8 +134,6 @@ Puts the thermostat into a temporary hold at the given temperature.
|
||||
| Service data attribute | Optional | Description |
|
||||
| ---------------------- | -------- | ----------- |
|
||||
| `entity_id` | yes | String or list of strings that point at `entity_id`'s of climate devices to control. Else targets all.
|
||||
| `target_temp_low` | no | Desired heating target temperature (when in auto mode)
|
||||
| `target_temp_high` | no | Desired cooling target temperature (when in auto mode)
|
||||
| `temperature` | no | Desired target temperature (when not in auto mode)
|
||||
|
||||
Only the target temperatures relevant for the current operation mode need to
|
||||
|
Loading…