mirror of
https://github.com/home-assistant/home-assistant.io.git
synced 2025-07-28 03:37:06 +00:00
Remove deprecated MH-Z19 CO2 Sensor integration (#21785)
This commit is contained in:
parent
0b04169d34
commit
5e202386f0
@ -1,70 +0,0 @@
|
||||
---
|
||||
title: MH-Z19 CO2 Sensor
|
||||
description: Instructions on how to integrate the MH-Z19 CO2 sensor with Home Assistant.
|
||||
ha_category:
|
||||
- DIY
|
||||
ha_release: 0.27
|
||||
ha_iot_class: Local Polling
|
||||
ha_domain: mhz19
|
||||
ha_platforms:
|
||||
- sensor
|
||||
---
|
||||
|
||||
<div class='note warning'>
|
||||
|
||||
This integration is deprecated and will be removed in Home Assistant Core 2022.4.
|
||||
|
||||
For more information see: [Architectural Decision Record 0019](https://github.com/home-assistant/architecture/blob/master/adr/0019-GPIO.md).
|
||||
|
||||
</div>
|
||||
|
||||
The MH-Z19 is a small non-dispersive infrared sensor that can measure CO2 level. High CO2 levels can lead to drowsiness, poor concentration, loss of attention or increased heart rate. The CO2 level outside is around 400ppm, but inside levels can reach between 1000 and 5000 ppm. High CO2 levels indicate that you should increase ventilation.
|
||||
|
||||
**Note:** the new version MH-Z19B requires the VIN to be connected to a 5V pin, rather than 3.3V.
|
||||
|
||||
## Configuration
|
||||
|
||||
To use this sensor in your installation, add the following to your `configuration.yaml` file:
|
||||
|
||||
```yaml
|
||||
# Example configuration.yaml entry
|
||||
sensor:
|
||||
- platform: mhz19
|
||||
serial_device: /dev/tty.SLAB_USBtoUART
|
||||
```
|
||||
|
||||
- **serial_device** (*Required*): The serial port to use. On *nix systems, it can often be identified by `$ ls /dev/tty*`
|
||||
- **name** (*Optional*): The name displayed in the frontend.
|
||||
- **monitored_conditions** (*Optional*, starting from version 0.40): Conditions to monitor. Supported conditions:
|
||||
- **co2** (*default*)
|
||||
- **temperature**
|
||||
|
||||
Full example:
|
||||
|
||||
```yaml
|
||||
sensor:
|
||||
- platform: mhz19
|
||||
serial_device: /dev/tty.SLAB_USBtoUART
|
||||
name: My MHZ19
|
||||
monitored_conditions:
|
||||
- co2
|
||||
- temperature
|
||||
```
|
||||
|
||||
## Raspberry Pi GPIO UART and the Home Assistant Operating System
|
||||
|
||||
To directly connect the sensor on the GPIO pins of a RPi, first append the following to `config.txt` in the boot directory:
|
||||
|
||||
```text
|
||||
enable_uart=1
|
||||
```
|
||||
|
||||
Then (after a reboot): you can setup the sensor using:
|
||||
|
||||
```yaml
|
||||
serial_device: /dev/ttyS0
|
||||
```
|
||||
|
||||
## Calibration
|
||||
|
||||
The MH-Z19B version of the sensor has Automatic Baseline Calibration enabled by default, which will calibrate the 400PPM level to the lowest measured PPM in the last 24h cycle. Currently the integration does not allow turning this functionality off.
|
@ -753,7 +753,6 @@
|
||||
/components/sensor.magicseaweed /integrations/magicseaweed
|
||||
/components/sensor.meteo_france /integrations/meteo_france
|
||||
/components/sensor.mfi /integrations/mfi#sensor
|
||||
/components/sensor.mhz19 /integrations/mhz19
|
||||
/components/sensor.miflora /integrations/miflora
|
||||
/components/sensor.min_max /integrations/min_max
|
||||
/components/sensor.mitemp_bt /integrations/mitemp_bt
|
||||
@ -1515,7 +1514,6 @@
|
||||
/components/meteoalarm /integrations/meteoalarm
|
||||
/components/metoffice /integrations/metoffice
|
||||
/components/mfi /integrations/mfi
|
||||
/components/mhz19 /integrations/mhz19
|
||||
/components/microsoft /integrations/microsoft
|
||||
/components/microsoft_face /integrations/microsoft_face
|
||||
/components/microsoft_face_detect /integrations/microsoft_face_detect
|
||||
@ -2361,6 +2359,9 @@
|
||||
/integrations/blinkt /more-info/removed-integration 301
|
||||
/components/tof /more-info/removed-integration 301
|
||||
/integrations/tof /more-info/removed-integration 301
|
||||
/components/mhz19 /more-info/removed-integration 301
|
||||
/components/sensor.mhz19 /more-info/removed-integration 301
|
||||
/integrations/mhz19 /more-info/removed-integration 301
|
||||
/components/bme280 /more-info/removed-integration 301
|
||||
/components/sensor.bme280 /more-info/removed-integration 301
|
||||
/integrations/bme280 /more-info/removed-integration 301
|
||||
|
Loading…
x
Reference in New Issue
Block a user